Test UPS on battery back-up, switch off utility supply and observe ‘backup indicator’
lights. Also your PC should continue to function normally.
1. Self-testing while Turn ON
Before turning on the UPS, the red/yellow/green led will be bright twice by turns.
then the UPS will be ready for operation.
2. Silence Function
In Battery Mode, shortly press the switch will enable or disable the buzzer.
But when UPS is low battery or overload, the buzzer can not be silenced.
3. Overload Protection
When UPS is overloaded while operating, which is not solved by the user in time,
it will cut off the output automatically after short time.
4. Autorun DC Start & AC Start
In DC mode, UPS discharges till battery run out and cut off, UPS autorun when
AC recover.
5. Low Battery shutdown
When the battery is about to be exhausted, UPS will shut down automatically to
protect battery’s life.
6. Turn Off UPS
1. AC Normal UPS will cut off the output and goes to AC standby mode by
pressing the switch.
2. Backup Press the switch, the UPS will be turned off after a long beep.
7. Manual Self-testing
User need to check the UPS ready for operation, Press the botton two time quickly
then UPS self test, UPS transfer AC to Backup and Backup to AC.
The trouble shooting chart covers most of the difficulties that you may encounter
under normal working conditions. If the UPS fails to operate properly, please review
the following steps before calling the service center.
1. Is the UPS plugged into a correct working outlet?
2. Is the line voltage within the rating specified?
3. Is the Fuse or Breaker / Circuit Protector on back panal open?
4. UPS has used long time > 2 Year that is short backup time or fault.
Please submit the following information when you call for service.
1. Model No. & Serial No.
2. Date of problem.
3. Full desciption of problem UPS.
OPERATION AND TEST THE UPS
TROUBLE SHOOTING
TROUBLE SHOOTING CHART
Non Input voltage with
1 beep every 8 seconds
UPS can not be turned
ON
UPS is not connecting
to AC and overloaded
Please connect to AC
and reduce the load
Please check the AC
Input Voltage
Please send to the
agency to repair
Replace the Fuse or Reset
the breaker, remove some
load and check if the load
is short-circuit or faulty
The input Fuse is burn
or Breaker is off
UPS suddenly turns to
Battery mode in spite of
utility line present
Save the data promptly
and Shut down the
operating system
Backup time less than
1 minute (low battery)
Close load and recharge
immediately
Battery problem
Replace the new battery
Recharge the battery for
atleast 12 hours and
retest the backup time
Use UPS > 2 year
Replace the new battery
Charging unit fault
Please send to the
agency to repair
Use more load over
Battery is not fully
charged
AC Input voltage is too
low
The UPS is failure
LCD Battery flashing
continuous with a beep
every 1 second
Back-up time less than
specified
Front Panel
Rear Panel
1. Input Voltage & Frequency
2. Output Voltage
3. Battery Percentage
4. Load Percentage
5. AC Mode
6. Battery Mode
7. Auto Mode
8. Silence Alarm
9. FAN
Specification
Model
PT2000P PT2200P
PT3000P
Power Rate
(VA/W)
2000
/
1200
2200
/
1320
3000
/
1400
Input Voltage
220
Vac +25% (165-275
Vac)
Output Voltage
(AVR)
220
Vac
+10% (198-242
Vac)
Output Voltage (Backup)
220
Vac
+5% (209-231
Vac)
Battery Capacity
12V 7.5Ah
x
4 12V 9.4Ah
x
4
Backup Time 5-30min (Depened on Load)
Charging Time
Batt. Cap.90% in 3-6
Hours
Protection System
Over / Under Voltage, Over Load, Short Circuit Protection
Low Battery Shutdown Fault and Battery Replacement
Transfer Time 4-10msec
LCD Display
Normal, Backup, Overload, Low Battery, Battery Replacement
Audible Alam Backup mode, Low battery, Overload, Fault
Control Program USB port & Cable with PowerManager software
AC Line Surge Protector
1,000,000W in 100
µ
s
/ 160 Joules in 2 ms
Tel
/
ADSL
Surge
TVSS Tel
/
Fax
/
ADSL
/
RJ11
/
RJ45
Standard Certification
ISO9001/14001, TIS.1291 1-2553, 2-2553, 3-2555, CE : IEC62040
Environment -45°C / RH 0-90% Non condensing
Dimensions (WxHxD) mm.
145x408x220
Weight kg. 19 21 21
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
10A250V~
MODEL. : PT2000P
S/N :
1. Tel / Fax Surge
2. USB Port
3. Fan
4. Outlets
5. Inlet
6. Circuit breaker
7. Laser Printer Outlet









6
5
7
AFTER SHIPMENT FROM THE FACTORY THE BATTERY
NEEDS RECHARGING. IF NOT USED FOR A LONG PERIOD
OF TIME, THE BATTERY WILL START SELF-DISCHARGING,
WHICH MAY RESRLT IN A SHORT SERVICE LIFE OF THE
BATTERY OR MAY EVEN CAUSE DAMAGE TO IT DURING
WARRANTY PERIOD. CARE SHOULD ALSO BE TAKEN TO
AVOID EXCESSIVE TEMPERATURE AROUND THE UPS,
WHICH COULD ALSO RESULT IN REDUCING SERVICE
LIFE OF THE BATTERY. TO ACHIEVE MAXIMUM SERVICE
LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS
SHOULD BE FOLLOWED.
Line Interactive UPS with LEDLine Interactive UPS with LED
CONNECT EQUIPMENT TO UPS
PLACE LOCATION THE UPS
Inspect items inside box:
User’s Manual & Warranty Card
UPS & Packaging Material
Mains Power Cord
Program & Communication(Option)
Examine the packing carton for damage. Notify your dealer immediately if damage
is observed. Store the packing in a safe place for possible future trans-shipment of
the UPS.
Avoid Direct Sulight.
Avoid Excessive Heat.
Avoid Excessive Humidity
or Liquids.
Avoid Excessive Dust.
IP20 Indoor Use.
The UPS is intended for indoor use only. Although your UPS is very rugged, its internal
components are not sealed from the environment. Kindly note the following.
Place location the UPS on a sturdy, dry surface in a wellventilated area away from
direct sources of heat. Leave at least 100mm clearance all around the UPS to provide
adequate ventilation.
CONNECT UPS TO POWER LINE
Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power the UPS
using a surge suppressor or power strip. The utility power Turn ON.
IP20
UPS INDICATORS AND CONTROLS
Product contains voltages, which are potentially
hazardous.
Qualified service personnel should perform all repairs.
Do not try to open the cover and to service the
system yourself, on user
serviceable parts inside.
Refer servicing to qualified service personnel only and warranty Condition
Product has its own internal energy source
(battery).
Outlet receptacles may be Hot even
when the product is not connected
to an AC supply.
In case of fire risky, please change the Fuse with
the same kind and same
rate or Reset breaker.
Product is intended for indoor use only.
Kindly note to avoid excessive heat, dust, humidity
CAUTION AND WARNING

i
Enable the UPS by turning on the Power ON/OFF switch, which is situated on the
front panel.
The UPS is now ready to use. Switch on your equipment and you are ready to function.
BATTERY MAINTENANCE / BATTERY CHARGING
ON / OFF SWITCH
Turn ON this button to supply power
to the
UPS outlets. To switch off power
to the UPS
outlets
Turn OFF the switch. This switch is
situated
on the front panel of the UPS.
BACKUP INDICATOR
(Red LED continuous bright)
The buzzer beeps every 8 seconds.
The battery is powering the UPS outlets.
The expected runtime for a typical personal
computer (PC) is about 10 to 40 minutes.
LOW BATTERY INDICATION
(Red LED continuous bright)
The buzzer beeps fast whenever the
battery is near the end of its runtime.
Promptly save your data and exit all
applications and shutdown the operating
system.
OVERLOAD INDICATION
The Yellow LED flashes, with continuous
beeping. UPS protects itself at this time.
Please move some load.
AC NORMAL INDICATOR
(Green LED continuous)
The UPS is supplying conditioned
utility power to its outlets.
UPS
BATTERY
OVERLOAD
PROTECTION
AUTOMATIC
VOLTAGE
REGULATION
AC SURGE
PROTECTION
Buck-2Boost
FEATUREFEATURE
Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power
the UPS using a surge suppressor or power strip. The utility power Turn ON.
Connect a Laser Printer or any
non-computer peripherals to
UPS outlets.

i
Pb
CAUTION :
BEFORE INSTALLATION & OPERATION
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
MODEL. : PT2000P
S/N :
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
MODEL. : PT2000P
S/N :
Do not connect a surge suppressor,
power strip, or extension cord
to the UPS outlet.
Chuphotic.User’s Manual English-22.PLUTO-Plus 2000-3000VA.Rev1.10/2019
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
10A250V~
MODEL. : PT2000P
S/N :
Laser Printer
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
10A250V~
MODEL. : PT2000P
S/N :
USB Port
SURGE LASER PRINTER
OUTPUT UPS
BREAKER
Press to Reset
INPUT 220V~,50Hz
10A250V~
MODEL. : PT2000P
S/N :

This manual suits for next models

3

Other Chuphotic UPS manuals

Chuphotic Venus Smart 1K User manual

Chuphotic

Chuphotic Venus Smart 1K User manual

Chuphotic PLUTO PT800 User manual

Chuphotic

Chuphotic PLUTO PT800 User manual

Chuphotic MOON-i MO850i User manual

Chuphotic

Chuphotic MOON-i MO850i User manual

Chuphotic KR6000 User manual

Chuphotic

Chuphotic KR6000 User manual

Chuphotic VENUS Ultimate S2.2 1KVA S User manual

Chuphotic

Chuphotic VENUS Ultimate S2.2 1KVA S User manual

Popular UPS manuals by other brands

Online ZINTO Series user manual

Online

Online ZINTO Series user manual

Riello UPS NetPower NPW 600 user manual

Riello UPS

Riello UPS NetPower NPW 600 user manual

PowerBoozt PB.UPS.2.2.24 user manual

PowerBoozt

PowerBoozt PB.UPS.2.2.24 user manual

Eaton 9E15Ki WIRING CONNECTIONS

Eaton

Eaton 9E15Ki WIRING CONNECTIONS

HP R1500 XR SERIES installation instructions

HP

HP R1500 XR SERIES installation instructions

Avem quirks Medisafe Plus manual

Avem quirks

Avem quirks Medisafe Plus manual

CyberPower UT1050EG quick start guide

CyberPower

CyberPower UT1050EG quick start guide

Eaton 3SMini quick start

Eaton

Eaton 3SMini quick start

Energenie EG-UPS-DC18 user manual

Energenie

Energenie EG-UPS-DC18 user manual

LEGRAND KEOR SP quick start guide

LEGRAND

LEGRAND KEOR SP quick start guide

Alpha Technologies CFR 1500RM Operator's manual

Alpha Technologies

Alpha Technologies CFR 1500RM Operator's manual

Tescom DS300HB Series user manual

Tescom

Tescom DS300HB Series user manual

EnerSys DataSafe XE Installation, operation and maintenance manual

EnerSys

EnerSys DataSafe XE Installation, operation and maintenance manual

Eaton 9395 UPS Installation and operation manual

Eaton

Eaton 9395 UPS Installation and operation manual

FSP Technology FP 400 quick guide

FSP Technology

FSP Technology FP 400 quick guide

Orvaldi 600 LCD user manual

Orvaldi

Orvaldi 600 LCD user manual

Salicru SPS 800 ADV RT2 quick start guide

Salicru

Salicru SPS 800 ADV RT2 quick start guide

Grafenthal PR-1000 user manual

Grafenthal

Grafenthal PR-1000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.