CircuPool CJ-1350 User manual

Owners Manual
This equipment must be installed and serviced by a qualified technician.
Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void the
warranty.
Notice to Installer
This manual contains important information about the installation, operation
and safe use of this product. Once the product has been installed this
manual must be given to the owner/operator of this equipment.
Cartridge Filters
CJ-1350, CJ-1800, CJ-2250, CJ2750
WARNING

TABLE OF CONTENTS
Introduction------------------------------------------------------01
Installation -------------------------------------------------------01
Start Up Procedure --------------------------------------------02
Maintenance---------------------------------------------------- 03
Cleaning ----------------------------------------------------------- 04
Flow Diagrams -------------------------------------------------- 04
Trouble Shooting Guide -------------------------------------- 05

CAUTION
CAUTION
01
CircuPool CJ-SERIES CARTRIDGE FILTERS
CJ-Series Cartridge Filters do not require a media such as sand or D.E powder to operate, instead the
filter contains a cartridge element which is easily removed to clean or replace.
All CJ-Series Cartridge Filters are ideal for use in swimming pools and spas. CircuPool CJ-Series
Cartridge Filters are also ideal for use when backwashing is impractical (when high water usage is
restricted or is not economical, for example).
INSTALLATION
Remove the cartridge filter from the carton and install the pressure gauge into the threaded port on
the filter lid provided. Using Teflon, wrap once around the brass pressure gauge thread in a clockwise
direction and screw into the threaded lid port.
Only hand-tighten the pressure gauge into the lid for sealing.
Place the Cartridge Filter into the required position. Ensure that it is on a flat level surface and
is aligned with the pump.
The Cartridge Filter has marked inlet and outlet ports.
Ensure that the pipe extending from the pump outlet will be connected to the inlet marked on the
Cartridge Filter.
Screw the supplied half barrel unions and collars onto the inlet and outlet before gluing the PVC
piping onto the filter.
Use only the recommended glue for the connection pipes and fittings.
Cut and fit the pipe and fittings onto and the pump the Cartridge Filter. REFER to Pump Installation
Manual for correct pump plumbing procedures.
It is best practice to fit all the cut pipe and fittings onto the filtration system before gluing. This will
ensure that the system has been aligned correctly.
Glue the pipe and fittings onto the pump, filter, and pool return lines and allow the glue to set for 24
hours before pressurizing the system.
It is advisable to bolt the filter down to the floor where the filter is located. This will prevent the
filtration plumbing from experiencing excessive stress with the expansion and operation of the filter
during regular cycles. It will also help to prevent unnecessary stress on the plumbing while unscrewing
the filter lid lock ring.

CAUTION
02
START UP PROCEDURE
CJ-Series Cartridge Filters are a simple and effective unit which will provide years of trouble-free service
if the following maintenance procedures are maintained.
Starting the filtration system either from new or after cleaning is exactly the same.
1. Make sure the cartridge(s) are in place and the lid is securely fastened
2. Ensure that all valves installed before or after the filter are open (if applicable).
3. Ensure that the filter is plumbed correctly. Pipe from pump outlet must be attached to the
filter inlet port.
4. Loosen the air bleed screw on top of the filter lid.
5. Prime the swimming pool pump. (Refer to the pump installation and operation manual).
6. Turn on the swimming pool pump and allow the pump to run until all the air has been expelled
from the filter vessel. Water will run from the air bleed screw.
7. Tighten the air bleed screw closed.
8. Verify that there is good water flow back to the pool.
9. The filter is primed and ready for operation.
In some cases, this may be required to be done a few times before the unit will remain primed and be
fully operational.
IMPORTANT: After startup, take note of what your pressure gauge
reads (when the cartridges are clean) –this is your baseline filter
operation pressure. You may wish to write this on your filter’s label
or record this in your notes. This will help you determine when
maintenance is needed.
Do not stand over the lid when adjusting the air bleed to purge the system of air. Injury may
occur if air bleed screw comes loose.

03
MAINTENANCE
To ensure that you get maximum life from your Cartridge Filter (and its internal cartridge element),
you will need to maintain the filter regularly.
When the filter is first started and has been purged of air, note the pressure on the pressure gauge.
This is what is known as the filter operation pressure and it is important that you be aware of this
figure.
All filtration systems will operate at different pressures depending on the pool hydraulics.
You will need to clean the filter cartridge element(s) once the pressure gauge has reached 7-10 PSI
above the operating pressure.
The CJ-Series Cartridge Filters have a maximum operating pressure of 50 psi.
EXAMPLE: A filter that operates normally at 15 psi needs to be cleaned at 22 psi.

04
CLEANING
For 135 –180 Sq. Ft Models:
Remove the cartridge element from the filter tank.
1. Using a garden type hose, clean the surface of the pleated
elements. Make sure to clean well between the pleats.
2. Place the cartridge back into the filter tank ensuring that it
is seated correctly.
3. Ensure lid “O”-ring is correctly re-installed.
4. Place the lid onto the tank and screw the lock ring down.
5. Ensure you’ve placed the lid “O”-ring on the lid before you
start up the filter.
6. Refer to the start up procedure to re-commence operation.
Do not over tighten the lid lock ring.
For 225 –270 Sq. Ft. Models:
1. First, use the air bleed screw located on top of the domed
lid to release any built-up pressure within the tank.
Unscrew the domed filter lid from the filter tank using the
two convenient molded handles.
2. Remove the cartridge element(s) from the filter tank.
3. Using a garden type hose clean the surface of the pleated
elements, making sure to clean well between the pleats.
4. Place the cartridge(s) back into the filter tank ensuring that
it is seated properly.
5. Ensure lid “O”-ring is correctly re-installed.
6. Place domed lid onto tank and screw tight using the two
molded handles.
7. Refer to the start up procedure to re-commence operation.
It is suggested that you should periodically remove the cartridge filter element and soak it
overnight in a suitable cartridge cleaning solution product. This will remove any debris not removed
by hosing down the element. Follow directions for use on the cleaning solution product. The
cleaning time depends upon the swimming pool condition and use. Intervals between cleaning the
element should not exceed a period of 12 months.
CAUTION
FLOW DIAGRAM
FLOW DIAGRAM

05
TROUBLESHOOTING GUIDE
SYMPTOMS
POSSIBLE PROBLEMS / SOLUTIONS
Water is not clear
Insufficient disinfectant level.
Incorrect pool chemistry.
Heavy bathing and/or dirt loads.
Incorrect flow.
Insufficient running times =. Increase pump run time.
Filter is dirty. Clean per instructions.
Hole in filter element.
Low water flow
Check strainer baskets for debris.
Check for air leaks on suction side.
Check for restrictions or blockage in either suction or return lines.
Filter needs to be cleaned or replaced.
Pool water level too low.
Pump not primed.
Pump impeller vanes blocked.
Strainer baskets not being used and/ or not being cleaned regularly.
Pump operating under speed (low voltage).
Short filter cycles
Presence of algae, check disinfectant content.
Check pH and total alkalinity.
Pump output exceeds design flow rate of
filter, check pump performance.
Ineffective cleaning, check conditions, replace filter cartridge.
High pressure on
start-up
Small eyeball fitting in Pool/ Spa.
Partially closed valve on return line.
Too large of pump, check selection.
Dirt returns to pool
Hole in filter cartridge, replace filter cartridge.
Worn “O”-ring seal inside filter, replace “O”-ring.

Filter Type: Filtration Area:
Cartridge 135 sq. ft. - 270 sq.ft
Cartridge Diameter: Flow Rate:
10.2" up to 134 gpm
Working Pressure: Maximum Pressure Drop:
up to 50.8 psi 2.9 psi
This manual suits for next models
3
Table of contents
Other CircuPool Water Filtration System manuals

CircuPool
CircuPool RJ Series User manual

CircuPool
CircuPool RJ16+ Operating instructions

CircuPool
CircuPool Universal UL-25 Operating instructions

CircuPool
CircuPool EDGE Series Operating instructions

CircuPool
CircuPool SJ Series Operating instructions

CircuPool
CircuPool SJ20A Operating instructions

CircuPool
CircuPool Core Series Operating instructions