53-30
Page 2 All
EFFECTIVITY:
CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR20
15 Dec 2014
2. MAINTENANCE PRACTICES
A. Empennage Access Panels (See Figure 53-301)
(1) Removal - Empennage Access Panels
(a) Serials 2222 & subs - if removing Access Panel RE3:
1Acquire necessary tools, equipment, and supplies.
2Secure suction cup handle to access panel.
(b) Remove screws securing access panel to empennage.
(c) Remove access panel.
(2) Installation - Empennage Access Panels
Note: Ensure contour of access panel matches fuselage.
(a) Serials 2222 & subs - if installing Access Panel RE3:
1Acquire necessary tools, equipment, and supplies.
2Secure suction cup handle to access panel.
(b) Position access panel to empennage.
WARNING: Installation of incorrect length screw in access panel may cause inter-
ference with pitch control system.
(c) Install screws securing access panel to empennage.
(3) Removal - Empennage Access Panel RE3 Seal
(a) Acquire necessary tools, equipment, and supplies.
Description P/N or Spec. Supplier Purpose
Suction Cup Handle - Any Source Secure access panel.
Description P/N or Spec. Supplier Purpose
Suction Cup Handle - Any Source Secure access panel.
Description P/N or Spec. Supplier Purpose
Plastic Scraper - Any Source Remove residue.
General Purpose
Adhesive Cleaner
(Refer to 51-30) (Refer to 51-
30)
Remove residue.
Masking Tape 2.0 inches (50.8
mm)
Any Source Restrict working area for adhe-
sive cleaner.
Isopropyl Alcohol 99% or higher
purity
Any Source Clean installation area.
Cotton Cloth (clean
and lint free)
- Any Source Clean installation area.