CLARIUS Hybrid IP User manual

Clarius® Hybrid IP
Infrared & White Light LED Illuminators
HM-8CW-IP HL-8CW-IP
HM-9CW-IP HL-9CW-IP
A range of combined Infra-Red and White-Light illuminators for CCTV,
featuring state of the art technology and installation friendly design.
• Energy efcient, low voltage operation for quick and easy installation
•Dual Core LED™ technology with advanced electronic control circuitry
deliver improved thermal management, long life and low cost of
ownership.
•CleanLITE® Self cleaning lens coating technology
• Semi covert / White-Light and covert White-light versions
• Built in photo cell
• Pressure equalisation vent prevents thermal expansion and pressure
cycling
• Interchangeable lens diffuser technology
Note:
• Only to be installed outside of arms reach
• Installation should be done by skilled personnel or under supervision of
such personnel
• The illuminator is - Medium - PoE and Large - PoE+.
• Only to be installed in restricted Access Areas
• Terminal block not included. Installation may require advice from a
qualied person
Optimum results are achieved by setting up at night and viewing the results
on a monitor.
1. Attach the illuminator mount to pan/tilt unit, wall or camera housing.
Using stainless steel xings suitable for the relevant application.
2. Connect the lamp to a suitable (SELV) power supply.
3. Commission the mains supply, camera and monitoring equipment.
4. Select the diffuser angle sheet required from the Clarius box (if required).
To position the required diffuser sheet, insert the tool included
in the slot at the bottom of the cover and prise upwards slowly.
Repeat at opposite end and carefully remove cover. Remove
backing sheet from the two adhesive discs and secure required
diffuser in position. Finally rmly clip the lens cover back into place.
5. Adjust the pan angle of the illuminator to match the camera eld of view.
6. Adjust the vertical alignment by loosening the side bolts (one on each
side of the main body) to maximise the results.
7. Tilt the lamp downwards until the rear part if the required eld of view is
saturated with light, as viewed on the monitor.
8. SLOWLY and GRADUALLY tilt the lamp upwards until the for part of the
required eld of view is illuminated correctly on the monitor.
RISK
GROUP 2
CAUTION
IR emitted
from this
product
Electronics High efciency surface mount high power LEDs with
advanced current limited integral control circuitry
Beam Angles 10º, 30°, 60° & 95°
Lens/Beam Pattern The illuminator should be matched to the scene and
the camera lens focal length
Wavelength 850nm and visible white light
940nm and visible white light
Expected Life 10 years
Consumption Medium Large
12W 26W
Input Voltage Medium Large
PoE, IEEE802af PoE+ IEEE802.3at
Operating Temp -50° to 60°C (-58° to 140°F)
Environmental IP66. Suitable for indoor and outdoor use
Construction Robust high quality aluminium extrusion
Front Window Polycarbonate high transmittance protection
(vandal-proof) with CleanLITE®technology
Dimensions 161 x 110 x 78mm
Weight 1.35Kg (3lbs)
Power Cable 1m with IP68 connector
Mount Black power coated stainless steel wall mount.
Adjustable via M6 Allen Key (included)
Quick Installation Guide
Unit 2, Birch Business Park, Whittle Lane, Heywood, Greater Manchester, OL10 2SX, UK
w: www.gjd.co.uk t: +44 (0) 1706 363 998 e: [email protected]
SPECIFICATION
DESCRIPTION
INSTALLATION

Illuminators are powered by Power over the Ethernet (PoE) via a network cable
connector to a PoE IEEE802af (Medium Illuminator) or PoE+ IEEE802.3at (Large
Illuminator) compliant switch.
The power consumption of the illuminators comply with PoE IEEE802af or PoE
IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied with a
1m long network cable. At the end of the network cable is a female RJ45 Cat5e compliant
connector with an IP68 rated cover.
The IP68 rated cover is supplied with the illuminator. Follow the instructions supplied with
the connector on how to attached if to the male Cat5e network cable.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED
TO THE NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN
GET INTO THE CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS
WOULD VOID THE WARRANTY ON THE PRODUCT.
Recommended PSU
Any IEEE802af (Medium Illuminator) or IEEE802.3at (Large Illuminator) compliant switch
or injector.
Power supply should be approved to relevant EN Safety standards.
Power Supply should be used with devices to protect against short circuits and overload.
External circuits used for interfacing with the illuminator (Camera Day/Night switching
and Telemetry) should be reinforced/double insulated from mains.
This product complies with the European Directive 2014/30/EU Electromagnetic
Compatibility and 2014/35/EU Low Voltage Directive by meeting the following standards:
This symbol on the product means that the electrical and/or electronic equipment
to which it relates should be disposed of at the end of life separately from domestic
household waste.
There are separate collection systems for recycling in the EU. For more information
please contact the Local Authority or supplier of the product.
Photocell
The photocell is designed to automatically switch the lamps on at dusk and turn off at
dawn. A high degree of hysteresis is incorporated to void on/off switching in marginal
conditions. The unit is factory set at approximately 30 Lux On and 70 Lux Off, but can be
adjusted.
Trouble Shooting
Ensure all tests are undertaken by a qualied, trained engineer and ensure safe working
practices are followed at all times.
Step 1: Basics
• Check power connection
• Ensure PoE+ specication
• Check the photocell is working - cover photocell ,light should turn on
• Ensure power supply is suitably rated to product - check the specications
Step 2: Set up Camera, lens and Illumination
• Check alignment of lamp
• Check camera lens- fully open at night and set correctly
• Check model number to performance specication to ensure required distance is
achievable
Step 3: Call for further assistance
If the lamp is still not delivering the required performance, please contact Technical
Support for further assistance
Note down:
• Model number and serial number of illuminator
• Camera make and model
• Lens make and model
SAFETY WARNING
• When the lamp is running, it is hot to touch. before touching switch off the illuminator and
allow to cool for a minimum of 10 minutes.
• The illuminator should be positioned so that prolonged starring into the illuminator at a
distance closed than 1m is not expected.
• The light source of this illuminator is not replaceable, when the light source reaches its
end of life the whole illuminator should be replaced.
• If the exible power cord of the illuminator is damaged it should be exclusively replaced
by an authorised service agent.
• This equipment is not suitable for use in locations where children are likely to be present
Factory Default Settings
When using the system for the rst time, or if a factory reset has been made, the
following settings are used.
Product IP number: 192.168.0.10 Subnet mask: 255.255.255.0
Default router: 192.168.0.1
Login
1. Open a web browser.
2. In the address eld, type in the selected unit IP-address.
3. The user interface login page is shown.
4. Create your username and password.
User manual can be downloaded from our website at www.gjd.co.uk
Pressure relief valve
IM Ethernet cable with
IP68 connector
LED indicator
Reset
CE-EMC EN55032
EN55024
EN 61547
EN 55015
EN 62493
EN 50130-4
(IT Immunity)
(IT Immunity)
(Lighting-Immunity)
(Lighting-Emission)
(Lighting -EMF)
(Alarm-EMC)
CE-LVD EN 60598-1
EN 60598-2-1
(Luminaires-General)
(Luminaires)
Safety EN 62471 Risk
group 2
(LED safety)
Environmental IEC/EN 60529
EN50130-5
IP66
(Alarm-environmental)
USA FCC, Class B
AUS RCM (AS/NZS CISPR 22 Class B)
RoHS: Restriction of Hazardous Substances European directive
202/95/EC
Certications
WEEE: Waste Electrical & Electronic Equipment European directive
202/96/EC
POWER AND CONTROL CABLE CONNECTIONS CLARIUS IP
CERTIFICATIONS
Image showing larger unit
This manual suits for next models
4
Other CLARIUS Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Barthelme
Barthelme AQUALUC C:URVE mini Instructions for installation and operation

thomann
thomann stairville dj lase performance 150 RGY user manual

Eurolux
Eurolux C552 quick start guide

GE
GE 19005LO quick start guide

Altman
Altman GALLERY SERIES quick start guide

Lightolier
Lightolier Calculite ProSpec PA3P3075 specification