CLARIUS IR User manual

Infra Red & White Light LED
Illuminators User Guide
IR WL
Description
A complete range in infra-red and white light illuminators for
CCTV, the visible and Invisible range feature state of the art
technology and installation friendly design.
• Energy efcient, low voltage operation for quick and
easy installation
• Latest high efciency surface mount LEDs with
advanced electronic control circuitry deliver improved
thermal management, long life and low cost of
ownership
• CleanLITE®Self cleaning lens Coating technology
• Semi-covert, covert and visible white light versions
• Built in photocell
• Easy integration with day/night cameras with relay
contacts indicating if the built in photocell has activated
the illuminator
• Remote telemetry input
• Easy access to power and photocell adjust
• Pressure equalisation vent prevents thermal expansion
and pressure cycling
Specification
Electronics High efciency surface mount high
power LEDs with advanced current
limited integral control circuitry
Beam Angles 10°, 30º, 60º, 100x50º and 120º
Lens/Beam Pattern The illuminator should be matched to
the scene and the camera lens focal
length
Wavelength 850nm,940nm and visible white light
Expected Life 10 years
Consumption Clarius IS / Clarius VS 13W
Clarius IM / Clarius VM 26W
Clarius IL / Clarius VL 39W
Clarius IX / Clarius VX 52W
Input Voltage 12-32V DC or 24V AC +/-10%
Operating Temp -50°to 60° (-58° to 140°F)
Environmental IP67
Construction Robust high quality aluminium extrusion
Front Window Polycarbonate high transmittance
protection (vandal-proof) with
CleanLITE®technology
Dimensions Clarius IS / Clarius VS 68 x 110 x 78mm
Clarius IM / Clarius VM 114 x 110 x 78mm
Clarius IL / Clarius VL 161 x 110 x 78mm
Clarius IX / Clarius VX 213 x 110 x 78mm
Weight Clarius IS / Clarius VS 750g (1.6lbs)
Clarius IM / Clarius VM 1.05kg (2.3lbs)
Clarius IL / Clarius VL 1.35kg (3lbs)
Clarius IL / Clarius VL 1.75kg (3.9lbs)
Power Cable 3m (9ft). Other lengths available to order
Mount Black power coated stainless steel wall
mount. Adjustable via M6 Allen Key
(included)
Installation
Note: The illuminator is low voltage 12-32V DC or 24V AC +/- 10%.
Optimum results are achieved by setting up at night and viewing the
results on a monitor.
1. Attached the illuminator mount to pan/tilt unit, wall or camera
housing
2. Connect the lamp to a suitable low voltage supply. Ensure that the
polarity is correct
3. Commission the mains supply, camera and monitoring equipment
4. Adjust the pan angle of the illuminator to match the camera eld
of view
5. Adjust the vertical alignment by loosening the side bolts (one on
each side of the main body) to maximise the results
6. Tilt the lamp downwards until the rear part if the required eld of
view is saturated with light, as viewed on the monitor
7. SLOWLY and GRADUALLY tilt the lamps upwards until the far part of
the required eld of view is illuminated correctly on the monitor
Unit 2 Birch Business Park, Whittle Lane, Heywood, Lancashire, OL10 2SX
www.gjd.co.uk [email protected] +44 (0) 1706 363 998

Power and Control Cable Connections
Remote Switching
The Illuminator may be activated remotely by a volt-free contact latched across
the telemetry wires (see Diag above).
Photocell following contact
Volt-free relay contact-normally open (day) to normally closed (night). See Diag
above.
Power Adjust
To adjust the power, rst unscrew the sealing cap then adjust the power
potentiometer clockwise to increase the power and counter clockwise to turn it
down. The unit is factory set to maximum output.
Photocell
The photocell is designer to automatically switch the lamps on at dusk and turn
off at dawn. A high degree of hysteresis is incorporated to void on/off switching in
marginal conditions. The unit is factory set at approximately 30 Lux On and 70 Lux
Off, but can be adjusted.
Photocell Sensitivity
To adjust the photocell sensitivity rst remove the sealing cap, then adjust the
potentiometer to turn the lamp on when lighting conditions are lighter or darker.
Adjust the counter clockwise to make the lamp turn on when it is lighted and
clockwise when it’s darker.
Disabling the photocell
To disable the photocell, adjust the sensitivity fully counter clockwise. This will
make the lamp turn on at all times.
Safety
WARNING: When the lamp is running, it is hot to touch, before touching switch off
the illuminator and allow to cool for a minimum of 10 minutes.
Do not stare directly into the lamp at a distance of less than 1.8m
PoE Models
The Clarius PoE/PoE+ series illuminators are powered by Power over the Ethernet
(PoE) via a network cable connector to a PoE IEEE802af/IEEE802at compliant
switch.
The power consumption of the illuminations comply with PoE IEEE802af and
IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied
with a 2.5m (8’) long network cable. At the end of the network cable is a female
RJ45 Cat5e compliant connector with an IP68 rated cover.
The mating IP68 rated over is supplied with the illuminator. Follow the instructions
supplied with the cover on how to attached if to the male Cat5e network cable.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED TO THE
NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN GET INTO THE
CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS WOULD VOID THE
WARRANTY ON THE PRODUCT.
Certifications
This product complies with the European Directive 89/336/EEC
Electromagnetic Compatibility and 73/23/EEC Low Voltage Directive by
meeting the following standards:
Safety: EN60598-1:2008 Electrical Safety
EN60825-1:2007 LED/Laser Eye Safety
EMC: EN6100-6-1:2007
EN6100-6-3:2007
EN6100-3-2:2006
EN6100-3-3:1995 AMDI & AMD2
FCC: FCC CFR Part 15. 107 and 15.109
IP: IP67 in accordance with EN 60529:1992
AMDI 7643. 1993 AMD2 10931, 2000
WEEE: Waste Electrical & Electronic Equipment European
directive 202/96/EC
RoHS: Restriction of Hazardous Substances European
directive 202/95/EC
This symbol on the product means that the electrical and/or electronic
equipment to which it relates should be disposed of at the end of life
separately from domestic household waste.
There are separate collection systems for recycling in the EU. For more
information please contact the Local Authority or supplier of the
product.
Trouble Shooting
Ensure all tests are undertaken by a qualied, trained engineer and
ensure safe working practices are followed at all times.
Step 1: Basics
• Check power connection
• Ensure power is 12-32V DC / 24V AC +/- 10%
•
• Check the photocell is working - cover photocell ,light should turn
on
• Ensure power supply is suitably rated to product - check the
specications
Step 2: Lamp Test
• Check current draw of lamp corresponds to specication
• Check current of lamp - see instructions for correct current settings
To check lamp current remove +ve (red) lead from power supply and
connect a multimetre (set to 10A) in line with the lamp. (One lead of
multimeter in common (COM) other lead into 10A socket of multimeter;
set multimeter to read Amps). Refer to PSI Specications for correct
current settings.
Step 3: Set up Camera, lens and Illumination
• Check alignment of lamp
• Check camera lens- fully open at night and set correctly
• Check model number to performance specication to ensure
required distance is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please
contact Technical Support for further assistance
Note down:
• Model number and serial number of illuminator
• Camera make and model
• Lens make and model
White. Volt Free / Night Switching (N/O)
Yellow. Volt Free/ Night Switching (COM)
Green Telemetry -
Blue Telemetry +
Red: +ve
Black: -ve
mount
Pot for photocell
adjustment
Pot for power
adjustment
Pressure relief
valve
Power and
control cable
This manual suits for next models
1
Other CLARIUS Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

American DJ
American DJ Cinco Star User instruction

EuroLite
EuroLite LED BAR-6 user manual

Ikan
Ikan LW5-2PT-KIT quick start guide

Enttec
Enttec DMXIS user manual

Federal Signal Corporation
Federal Signal Corporation IPX6 IMPAXX Installation and maintenance manual

Setolite
Setolite ALDEBARAN HERO Instructions for use