Claypaky ALPHA PROFILE 1500 ST User manual

1
C61330
C61331
1
INSTRUCTION MANUAL
ENGLISH
ALPHA PROFILE 1500
ALPHA PROFILE 1500 ST
INDEX
Page Contents
2 Safety Information
3 Unpacking and preparation
4 Installation and start-up
5 Control panel
7 Menu setting
16 Maintenance
24 Technical information
24 Cause and solution of problems
25 Channel functions
Co gratulatio s o choosi g a Clay Paky product!
We tha k you for your custom.
Please ote that this product, as all the others i the rich Clay
Paky ra ge, has bee desig ed a d made with total quality to
e sure excelle t performa ce a d best meet your expectatio s
a d requireme ts.
Carefully read this instruction manual in its entirety and keep it
safe for future reference. It is essential to know the information
and comply with the instructions given in this manual to ensure
the fitting is installed, used and serviced correctly and safely.
CLAY PAKY S.p.A. disclaims all liability for damage to the fitting
or to other property or persons deriving from installation, use and
maintenance that have not been carried out in conformity with this
instruction manual, which must always accompany the fitting.
CLAY PAKY S.p.A. reserves the right to modify the characteristics
stated in this instruction manual at any time and without prior
notice.

2
ALPHA PROFILE 1500 & ST
SAFETY INFORMATION
EN
IT
DE
ES
FR
RU
SAFETY INFORMATION
IMPORTANT: Clay Paky recommends you carefully read and keep the safety information on this product, also
available in digital format at the following link:
http://www.claypaky.it/en
Ref: [ IS00Q – Safety Information Alpha 1500]
INFORMAZIONI DI SICUREZZA
IMPORTANTE: Clay Paky raccomanda di leggere accuratamente e conservare le informazioni di sicurezza relative
a questo prodotto, sempre reperibili in versione digitale al seguente link:
http://www.claypaky.it/en/download
Rif: [ IS00Q – Safety Information Alpha 1500]
INFORMATIONEN ZUR SICHERHEIT
WICHTIG: Clay Paky empfiehlt, die Sicherheitsinformationen bezüglich dieses Produkts genau zu lesen und
aufzubewahren. Sie sind in Digitalversion immer unter folgendem Link auffindbar:
http://www.claypaky.it/en/download
Ref: [ IS00Q – Safety Information Alpha 1500]
INFORMACIONES DE SEGURIDAD
IMPORTANTE: Clay Paky recomienda leer detenidamente y conservar la información de seguridad relativa a este
producto. Además, está disponible una versión digital de la misma en el siguiente enlace:
http://www.claypaky.it/en/download
Ref: [ IS00Q – Safety Information Alpha 1500]
CONSIGNES DE SÉCURITÉ
IMPORTANT: Clay Paky recommande de lire attentivement et de conserver les informations de sécurité relatives
à ce produit, disponibles en version digitale au lien suivant:
http://www.claypaky.it/en/download
Réf. : [ IS00Q – Safety Information Alpha 1500]
ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ
ВАЖНО: Clay Paky рекомендует внимательно прочитать и сохранить инструкцию по технике безопасности
данного изделия, которая всегда доступна в электронном формате по следующей сс лке:
http:// .claypaky.it/en/do nload
Наименование: [ IS00Q – Safety Information Alpha 1500]

3
ALPHA PROFILE 1500 & ST
UNPACKING AND PREPARATION
90°
90°
90°
90°
LOCKED
UNLOCKED
PAN Mechanism Lock and Release (every 90°) - ig. 2
TILT Mechanism Lock and Release (every 45°) - ig. 3
2
45°
45°
45°
45°
45°
45°
UNLOCKED
LOCKED
3
Packing contents - ig. 1
Lampada 1500W
(installata nel proiettore)
IST00 /001
2 x 183102/805
1

4
ALPHA PROFILE 1500 & ST
INSTALLATION AND START-UP
4
1
2
1
23
5
Connecting and disconnecting power cable - ig. 5
Installing the projector - ig. 4
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING: with the ex eption of when the proje tor is positioned on the floor, the safety able must be fitted. (Cod. 105041/003 available on request).
This must be se urely fixed to the support stru ture of the proje tor and then onne ted to the fixing point at the entre of the base.

5
ALPHA PROFILE 1500 & ST
CONTROL PANEL
Switching on the projector - ig. 8
Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
Model Firmware xxx (Fixture ID) System errors
Alpha PROFILE Version X.X.X Dmx Address xxx E: .........................
1500 Date - Hour W: .........................
On conclusion of resetting in case of absence of dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control panel
( ig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions:
rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the ixture ID address (if set).
During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
F
key will be cancelled.
1
2
Dmx Address
Warning Message
Fixture ID
MAINS
8
Connecting to the control signal line (DMX) - ig. 7
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.
L
N
6
7
SIGNAL
SCREEN
DMX 512
5 PIN
1
2
3
4
5
SIGNAL
SCREEN
1
3
2
DMX 512
3 PIN
SIGNAL
SIGNAL
DMX 512
Connecting to the mains supply - ig. 6
Mains
Co ti ue ➔

6
ALPHA PROFILE 1500 & ST
28
28
Reversal of the display - ig. 9
To activate this function, press UP
B
and DOWN
C
keys simultaneously while the display is in the rest mode. This status will be memorised and
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
Setting the projector starting address
On each projector, the starting address must be set for the control signal (addresses from 1 to 512).
The address can also be set with the projector switched off.
Setting the projector Fixture ID
On each projector, the ixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).
The ixture ID address can be set with the projector switched off.
9
Functions of the buttons - Using the menu
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press
F
to momentarily activate the display and thus access the settings. Once the required operations have been carried out,
the display will switch off again after a wait time of 30 seconds.
USING THE MENU:
1) Press
F
once – “Main Menu” appears on the display.
2) Use the UP
B
and DOWN
C
keys to select the menu to be used:
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options.
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects.
• Advanced (Advanced Menu): Access to the “Advanced menu” is recommended for a trained technical personnel.
3) Press
F
to display the first item in the selected menu.
4) Use the UP
B
and DOWN
C
keys to select the MENU items.
Confirms the displayed value, or activates the displayed function, or enters the successive
menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
Return to the top level
Commute from units, tens, hundreds, in the "Address", " ixture ID" and "Calibration" menù.
F
C
DOWN
B
UP
D
LE T
E
RIGHT

System
Errors
Information
ixture
Hours
Lamp
Hours
3
Lamp
Strikes
System
Version
Board
diagnostic
Dmx
Monitor
ans
Monitor
Sensor
Status
Network
parameters
7
ALPHA PROFILE 1500 & ST
MENU SETTING
Set Up
Option
Information
Manual
Control
Test
Advanced
1
4
Lamp
Manual
Control
Reset
Channel
65
Access code
1234
Advanced
Calibration
Upload
irmware
Setup
Model
Pan / Tilt
Colour
Beam
Gobo
All
Test
2
Lamp Dmx
Pan / Tilt
Option
Invert
Pan
Invert
Tilt
Swap
Pan-Tilt
Encoder
Pan-Tilt
P/T Homing
Mode
Pan Home
Def Pos
Tilt Home
Def Pos
Color Color
Mixing
ixed Wheel
Shortcut
Macro Color
Adjustment
Shutter Shutter
On Error
Dimmer On
Shutter
Autofocus
Mode
Limited Zoom
Range
Complete
Zoom Range
Macro
Effects
Macro group
size
Macro
fixture Id
Silent
Mode Standard
Quiet
Lamp
Dimming
1500W-
800W
1500W-
1200W
Power Mode 1500-1200
ull fan speed
1200
Low fan speed
1500-1200
Auto fan speed
Display
Setting Default Preset
User Preset 1
User Preset 2
UserPreset 3
Dmx
Address
Channel
Mode
Ethernet
Interface
ixture ID
Co ti ue ➔

8
ALPHA PROFILE 1500 & ST
DMX ADDRESS
NOTE: without the DMX signal the Address (XXX) flashing
Allows you to select the DMX ADDRESS
1) Press
F
- the current DMX Adress appear on the display.
2) Use the UP
B
, DOWN
C
, RIGHT
E
keys to plan the DMX
Address.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
CHANNEL MODE
Allows you to select a channel arrangement from the two available.
1) Press
F
- the current settings appear on the display (Standard or
Vector).
2) Use the UP
B
and DOWN
C
keys to select one of the following
settings:
- Standard
- Vector
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
FIXTURE ID
Allows you to select the IXTURE ID
1) Press
F
- the current ixture ID appear on the display.
2) Use the UP
B
, DOWN
C
, RIGHT
E
keys to plan the ixture ID.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
ETHERNET INTERFACE
It lets you set the Ethernet settings to be attributed to the projector.
1) Premere
F
.
2) Use the UP
B
and DOWN
C
keys to select the “Ethernet Interface”
options to set:
Control Protocol
It lets you select the “Control Protocol” Art-net to assign according to the
control unit used:
1) Press
F
the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
- Disabled
- Art-net on IP 2
- Art-net on IP 10
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
Repeat on DMX
It lets you enable the transmission of the Ethernet protocol by DMX signal
to all the connected projectors.
1) Press
F
the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
- Disabled: DMX transmission disabled.
- Enabled on primary: DMX transmission enabled.
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
Universe
It lets you assign the “Universe” number to be assigned to a series of
projectors.
1) Press
F
– the current Universe address appears on the display.
2) Use the UP
B
, DOWN
C
, RIGHT
E
keys to set the Universe address.
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
Custom IP address
Allows you to set the IP address manually by the user default.
Custom IP mask
Allows you to set manually the Subnet Mask by the user default.
SET UP MENU
Set Up Dmx
Address
Channel
Mode
ixture Id
Address xxx
Standard
Vector
Value xxx
Ethernet
Interface
Control
Protocol
Repeat on
DMX
Universe
NOTE: On grey the default options
Custom IP
address
Custom IP
mask

9
ALPHA PROFILE 1500 & ST
LAMP DMX
Used for enabling lamp remote control channel.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
the lamp remote control channel.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
PAN / TILT
Invert pan
Used for reversing Pan movement.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
PAN inversion.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
Invert tilt
Used for reversing tilt movement.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
Tilt inversion.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
Swap Pan-Tilt
Used for swapping Pan and Tilt channels (as well as Pan fine and Tilt fine).
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
Pan and Tilt channel swap.
3) Press
F
to confirm the selection or LE T
D
tto keep current settings.
Encoder Pan-Tilt
Used for enabling the Pan / Tilt encoders.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
Pan / Tilt encoders.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
You can quickly disable the Pan and Tilt Encoder by simultaneou-
sly pressing the UP
B
and DOWN
C
keys in the ''Main Menu''.
P/T Homing Mode
Lets you set the initial projector Reset mode.
1) Press
F
, the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following
settings:
Standard: Pan & Tilt are simultaneously reset.
Sequenced: Tilt is reset first followed by Pan.
3) Press
F
to confirm the selection or LE T
D
to keep the current
setting.
Pan Home Def Pos
Lets you assign the Pan channel “home” position at the end of Reset,
without a DMX input signal.
1) Press
F
, the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following
settings:
0 degree
90 degrees
180 degrees
270 degrees (default)
3) Press
F
to confirm the selection or LE T
D
to keep the current
setting.
Swap
Pan-Tilt
On
Off
Encoder
Pan-Tilt
On
Off
OPTIONS MENU
Lamp Dmx
Pan / Tilt
Option On
Off
Invert
Pan
On
Off
Invert
Tilt
On
Off
P/T Homing
Mode
Standard
Sequenced
Pan Home
Def Pos
Co ti ue ➔

10
ALPHA PROFILE 1500 & ST
Tilt Home Def Pos
Lets you assign the Tilt channel “home” position at the end of Reset,
without a DMX input signal.
1) Press
F
, the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following
settings:
0%
12.5%
25%
50% (default)
75%
87.5%
100%
3) Press
F
to confirm the selection or LE T
D
to keep the current
setting.
COLOR
Color mixing
Used for reversing the CMY color mixing system.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys select one of the following settings:
RGB color mixing mode
CMY color mixing mode
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
Fixed wheel short-cut
Used for optimizing color change time so that the disc turns in the direc-
tion that requires shorter movement.
1) Press
F
– the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
color change optimization.
3) Press
F
to confirm the selection, or LE T
D
to keep current settings.
Macro color adjustment
It lets you enable the overwriting of a “Macro Colour” with the Cyan,
Magenta, Yellow, CTO and Colour wheel channels.
Press
F
the current setting appears on the display.
1) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
the overwriting.
2) Press
F
to confirm the selection or LE T
D
to keep the current setting.
SHUTTER
Shutter on error
Used for automatically closing the stop/strobe in the event of Pan/Tilt
position error.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
automatic stop/strobe closing in the event of Pan/Tilt position error.
3) Press
F
to confirm the selection, or LE T
D
to keep current settings.
Dimmer on Shutter
Enables automatic closing of the dimmer when the strobe is completely closed.
1) Press
F
– the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
the automatic closing of the dimmer.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
AUTO-FOCUS MODE
It lets you select the “Auto-focus Mode” from the two available.
1) Press
F
the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
Limited Zoom Range: The “Autofocus” works only in the optical run
that was specifically designed for the projector in question.
Complete Zoom Range: The “Autofocus” also works in overrun
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
Tilt Home
Def Pos
Color Color
Mixing
RGB
CMY
ixwheel
Shortcut
On
Off
Macro Color
Adjustment
On
Off
Shutter Shutter
On Error
On
Off
Dimmer On
Shutter
On
Off
Auto-focus
Mode
Limited
Zoom Range
Complete
Zoom Range

11
ALPHA PROFILE 1500 & ST
MACRO EFFECTS
It lets you select the “Macro Effects” from the two available.
1) Press
F
the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
Macro group size
It lets you set the number of projectors to be included in the macro mode
operation.
1) Press
F
2) Use the UP
B
, DOWN
C
, RIGHT keys to set the number of projectors
to be included in the “Macro Effect” operation.
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
Macro fixture Id
It lets you attribute an ID address to the projector for the phase
displacement for the scene’s starting time in Macro mode.
1) Press
F
2)
Use the UP Band DOWN Ckeys to select one of the following settings:
Fixed to X. (to assign to all the projectors to be included in the Macro
operation).
Auto by DMX Address: According to the DMX address, it automatically
detects the starting sequence of the scene in the Macro mode (to assign
to all the projectors to be included in the Macro operation).
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
SILENT MODE
It lets you select the “Silent Mode” from the two available.
1) Press
F
the current setting appears on the display.
2)
Use the UP Band DOWN Ckeys to select one of the following settings:
Standard: Maximum speed and consequently maximum effects noise level.
Quiet: reduces the speed of some effects, thereby reducing their noise level.
3) Press
F
to confirm the selection or LE T
D
to keep the current setting.
LAMP DIMMING
This lets you select the lamp “dimmer” mode, selecting one of the two
available modes:
•1500W-800W: Default settings, the lamp electronically "dims” from
1500W to 800W and mechanically dims from 800W to 0. Visually, the
Dimmer curve is high performance but a slight flicker is noted in some
dimming positions.
•1500W-1200W: The lamp electronically “dims” from 1500W to 1200W
and mechanically dims from 1200W to 0. No lamp flicker is visible
when this option is selected. The "dimmer" blades are subject to
higher thermal stress. Thus, more frequent "dimmer" blade
maintenance may be required.
POWER MODE
Allows you to select a Power Mode from the three available.
1) Press
F
- the current settings appear on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
-1500-1200W Full fan speed: Lamp can change from full-power
(1500W) to half-power (1200W) using the LAMP CONTROL channel.
ans always work at ull speed
-1200W Low fan speed: Lamp constantly works in half-power mode
(1200W) while the an always works at Low speed. With LAMP
CONTROL channel you can only switch the lamp ON and O .
-1500-1200W Auto fan speed: Lamp can change from full-power
(1500W) to half-power (1200W) using the LAMP CONTROL channel.
Automatically the fans switch from ull speed to Low speed respectively.
3) Press
F
to confirm the selection or LE T
D
to keep current setting.
Macro
Effects
Macro fixture Id
Macro group
size
Silent
Mode Standard
Quiet
Power Mode
1500-1200
ull fan speed
1200
Low fan speed
1500-1200
Auto fan speed
Lamp
Dimming
1500W-
800W
1500W-
1200W
Co ti ue ➔

12
ALPHA PROFILE 1500 & ST
Reset To
Dafault
Go Back
Setting Default
Preset
Load
Preset 1
Save To
Preset 1
User
Preset 1
Load
Preset 2
Save To
Preset 2
User
Preset 2
Load
Preset 3
Save To
Preset 3
User
Preset 3
DISPLAY
Used for automatically reduce brightness on the display after about 30
seconds in idle.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN
C
keys to enable (On) or disable (Off)
the decreasing of display brightness.
3) Press
F
to confirm the selection or LE T
D
to keep current settings.
SETTING
Used to save 3 different settings of the items in the options menu and
relative submenus.
1) Press
F
- “Default preset” appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following
configurations:
- Default preset (*)
- User preset 1
- User preset 2
- User Preset 3
3) Press
F
- “Load preset X” appears on the display.
4) Use the UP
B
and DOWN
C
keys to select:
- Load preset X to recall a previously stored configuration.
- Save to preset X to store the current configuration.
a confirmation message (Are you sure?) appears on the display.
5) Select YES to confirm the selection or NO to keep the current setting
and return to the next higher level.
(*) DE AULT PRESET
By pressing the RIGHT
E
key and the LEFT
D
key simultaneously
once entered in the "main menu" it is possible to quickly (short cut)
reset the default settings (DEFAULT PRESET).
Used for restoring default values on all options menu items and relevant
submenus.
1) Press
F
, a confirmation message (Are you sure?) appears on the
display.
2) Select YES to confirm the selction or NO to keep current setting.
OPTION DE AULT
Lamp DMX On
Invert Pan Off
Invert Tilt Off
Swap Pan-Tilt Off
Encoder Pan-Tilt On
P/T Homing Mode Standard
Pan Home Def Pos 270 degrees
Tilt Home Def Pos 50%
Colour mixing CMY
ixed Wheel Shortcut On
Macro Color Adjustment On
Shutter on error Off
Dimmer on Shutter Off
Auto-focus mode Limited zoom range
Silent mode Standard
Power mode 1500-1200w full fan speed
Display On
On
Off
Display

13
ALPHA PROFILE 1500 & ST
Lamp
Hours
Total XXX
Partial XXX
Reset...
Lamp
Strikes
Total XXX
Partial XXX
Reset...
Information System
Errors
ixture
Hours
Total XXX
Partial XXX
Reset...
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing
F
you are allowed to reset the SYSTEM ERRORS list.
A confirmation message (Are you sure you want to clear error list ?)
appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working life hours (from manufacture to date).
Partial counter
Counts the number of partial projector working life hours since the
last reset to date.
2) Press
F
to reset partial projector working hours a confirmation
message (Are you sure?) appears on the display.
3) Select YES to reset partial projectors counter or NO to keep the
current setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting and
return to the top menu level
LAMP STRIKES
Used for displaying the number of times the lamp was turned on (total and
partial).
1) Press
F
- the number of times the lamp was turned on (total and
partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last
reset to date.
2) Press
F
to reset partial lamp strikes hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
SISTEM VERSION
Used for displaying the software and hardware version of each board
installed in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 6-Ch (6 channel board)
3: 8-Ch (8 channel board)
4: 6-Ch (6 channel board)
INFORMATION MENU
System
Version
Board Revis. Hw.rv.
CPU brd x.x.x x.x
com.dev x.x
0: PT-3f x.x x.x
1: 8-Ch x.x x.x
2: 6-Ch x.x x.x
3: 8-Ch x.x. x.x
4: 6-Ch x.x. x.x
Co ti ue ➔

14
ALPHA PROFILE 1500 & ST
BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 6-Ch (6 channel board)
3: 8-Ch (8 channel board)
4: 6-Ch (6 channel board)
DMX MONITOR
Used for displaying the projector DMX channel level in bit (Val) and in
percentage (Perc).
FANS MONITOR
Used for displaying the speed of each fan installed in the projector:
Pwr.Sup (Power supply an)
Ball. IN (Ballast IN an)
Ball. Out (Ballast OUT an)
Eff.IN (Effects IN an)
Eff.OUT (Effects OUT an)
Lamp (Lamp an)
Lamp (Lamp an)
Gobo (Gobo an)
Board (Yoke Board an)
SENSOR STATUS
It lets you check the correct operations of each "sensor” installed in the
projector, each channel is associated with one of the following three
parameters:
• n.a.= sensor not available
• ON= sensor working
• O = sensor defective
NETWORK PARAMS
Allows the "Network" parameters of the projector to be displayed or:
IP address: Internet Protocol address (two projectors must not have the
same IP address)
IP mask: 255.0.0.0
Mac address: Media Access Control: the projector’s Ethernet Address.
LAMP
Used for turning lamp on and off from the projector control panel.
1) Pres
s
F
-
the current settings appear on the display (On or Off).
2) Use the
UP
B
and DOWN
C
keys to turn the lamp on (On) or off (Off)
3) Press
F
to confirm the selection or
LE T
D
to keep current settings
and return to the top level.
RESET
Used for resetting the projector.
1) Press
F
to reset the projectors, a confirmation message (Are you sure ?)
appears on the display.
2) Select YES to starting reset the fixture or NO to keep the current setting
and return to the top menu level.
CHANNEL
Used for setting channel levels from the projector control panel.
1) Press
F
- the first channel appears on the display.
2) Use the UP
B
and DOWN
C
keys to select the required channel:
3) Press
F
and use the UP
B
and DOWN
C
keys to select the
required DMX level (value between 0 and 255).
4) Press LE T
D
to return to the top menu level.
Channel
MANUAL CONTROL
Lamp
Manual
Control
On
Off
No
Yes
Reset
ans
Monitor an Speed (RPM)
Pwr.Sup XXXX
Ball.In. XXXX
Ball.Out XXXX
Eff.In XXXX
Eff.Out XXXX
Lamp XXXX
Lamp XXXX
Gobo XXXX
Board XXXX
Board
Diagnost.
Dmx
Monitor
Board Status Err%
0:PT-3f Good 0.00
1:8-Ch Good 0.00
2:6-Ch Good 0.00
3:8-Ch Good 0.00
4:6-Ch Good 0.00
Network
params
Sensor
Status

15
ALPHA PROFILE 1500 & ST
To enable the "Advanced Menu" set up the "Access code" (1234) using the
UP
B
, DOWN
C
, RIGHT
E
keys.
Press
F
- "Menu advanced" appears on the display
UPLOAD FIRMWARE
Allows you to transfer the firmware from 1 fixture to all the connected fixtures.
1) Press
F
, a confirmation message appears on the display.
2) Select YES to start the firmware loading or NO to keep the current set-
ting and return to the top menu level
SETUP MODEL
Allows you to change the default model of projector.
1) Press
F
a confirmation message appears on the display.
2) Select YES to define the model of projector or NO to keep the current
setting and return to the top menu level.
CALIBRATION
Allows you to adjust effects from the control panel to obtain perfect unifor-
mity between the projectors.
1) Press
F
- “channels” appears on the display.
2) Using the UP
B
and DOWN
C
keys, select the effect you wish to
regulate.
3) Press
F
and use the RIGHT
E
, UP
B
and DOWN
C
buttons to
make the adjustment by setting a value between 0 and 255.
4) Press
F
to confirm the selection
or
LE T
D
to keep current set-
tings and return to the top level.
FACTORY DEFAULT
Allows you to restore default values of all channels (128).
1) Press
F
– a confirmation message appears on the display (Reset
calibration to factory default ?).
2) Select YES to reset calibration to factory default or NO to keep the
current setting and return to the top menu level.
ADVANCED MENU
Advanced
Code
1234
Calibration
actory
Default
Upload
irmware
Transfer the firmware on all
the connected fixtures ?
Are you sure ?
Yes/No
Setup
Model
Changing to a wrong model
may damage the fixture.
Are you sure ?
Yes/No
AUTOTEST
Allows you to check the proper functioning of effects.
1) Press
F
.
2) Use the UP
B
and DOWN
C
keys to select the required test.
3) Press
F
to confirm the selection or LE T
D
to return to the top
menu level.
Test sequence:
Pan - Tilt effects (Pan & Tilt)
Colour effects (CMY, colour wheel, CTO)
Beam effects (Stopper-Strobe / Dimmer / Iris / Prism / rost, ocus,
Zoom, Animation disk)
Gobo effects ( ixed gobo / Rotating gobo)
All effects
Test
Pan-Tilt
Colour
Beam
Gobo
All
TEST MENU

16
ALPHA PROFILE 1500 & ST
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section.
Opening the head covers - ig. 11.
Closing the head covers - ig. 12.
1/4 Turn
1
3
21
2
1/4 Turn
1
4
5
11 12
MAINTENANCE

17
ALPHA PROFILE 1500 & ST
Fan support plate opening and closing (Lower side) - ig. 16
Lower Side
2
1
16
1
2
14
15
1
2
13
Lamp change - ig 14
Take the new lamp out of its package and insert in the fitting.
WARNING: do not tou h the lamp’s envelope with bare hands.
Should this happen, lean the bulb with a loth soaked in al ohol
and dry it with a lean, dry loth.
Lamp regulation - ig. 15
To centre the lamp, turn the three adjusting screws as shown in the figure.
CAUTION:
ast lamp ON-O cycles (for example 10 minutes ON / 10 minutes
O ) will reduce the lamp life.
Opening and closing lamp compartment - ig. 13
Co ti ue ➔

18
ALPHA PROFILE 1500 & ST
Fan support plate opening and closing (Upper side) - ig. 17
Upper Side
2
1
17
2
1
085911/001
085901/001
085903/001
085907/001
085912/001
085906/001
085904/001
085908/001
Lower Side
18
Replacing fixed gobos (ø 31.5 mm - max 25 mm image - thickness max 1 mm) - ig. 18
IMPORTANT: Please contact CLAY PAKY before using customized gobos.

19
ALPHA PROFILE 1500 & ST
19
Lower Side
2
1
1
GOBO ROTATION
084632/001
105115/802 084626/001
084628/001
084630/001 084625/001
GOBO
INDEX
2
20
21
To determine which side of a godo is coated, hold an odject up to it. On the
uncoated side, there is a space between the object and its reflection.
Grey/Black side
away from lamp
Reflective side
towards lamp
Coated side
towards lamp
Coated side
Uncoated side Uncoated side
COATED GLASS GOBOS TYPE 1 COATED GLASS GOBOS TYPE 2
Gobo orientation - ig. 21
The pictures shown the correct gobos orientation.
Replacing rotating gobos (ø 37.5 mm - max 25 mm image – thickness 1 mm) - ig. 20
IMPORTANT: Please contact CLAY PAKY before using customized gobos.
IMPORTANT: Use only glass gobos on the rotating gobos wheels.
Bearing group replacement - ig. 19
Co ti ue ➔

Extraction of the effect modules: Preliminary operations - ig. 23
5
1
Thermostat
3
4
6
2
7
Lower Side
23
20
ALPHA PROFILE 1500 & ST
Periodical cleaning - ig. 22
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the
working environment (air humidity, presence of dust, salinity, etc.).
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended
that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
•General cleaning of internal parts.
•Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.
•General visual check of the internal components, cabling, mechanical parts, etc.
•Electrical, photometric and functional checks; eventual repairs.
Upper Side Lower Side
22
This manual suits for next models
1
Table of contents
Other Claypaky Speakers manuals

Claypaky
Claypaky C61375 User manual

Claypaky
Claypaky ALPHA SPOT QWO 800 ST User manual

Claypaky
Claypaky ALPHA PROFILE 700 User manual

Claypaky
Claypaky C61330 User manual

Claypaky
Claypaky C61378 User manual

Claypaky
Claypaky SUPERSHARPY C61390 User manual

Claypaky
Claypaky C61381 User manual

Claypaky
Claypaky ALPHA BEAM 700 User manual

Claypaky
Claypaky MYTHOS C61391 User manual

Claypaky
Claypaky C61419 User manual