CleanFreak TPL-PH12 User manual

TPL-PH12
PROFESSIONAL
POWER WAND FOR CARPET CLEANING
OWNER’S/OPERATOR’S MANUAL
WWW.CLEANFREAK.COM
FOR COMMERCIAL USE ONLY
REVISION 10-12-18

UNPACKING YOUR NEW TRUSTED CLEAN
TPL-PH12 POWER WAND::
When your package is delivered, check the carton care-
fully for signs of rough handling. If the TPL-PH12 is
damaged, notify the carrier immediately and request an
inspection. Be sure to keep the carton, packing inserts,
packing lists and carrier’s receipt until the inspector has
veried your claim.
CLEANFREAK’s liability ceases when the carrier picks
up the shipment. However, our customer service sta
will be happy to furnish any information needed in
connection with the claim and will attempt to expedite a
resolution.
PLEASE READ BEFORE
OPERATING YOUR NEW TPL-PH12:
Read the manual carefully and completely before at-
tempting to operate the unit. is manual has important
information for the use and safe operation of the ma-
chine. Keep this manual handy at all times.
is equipment has been engineered and manufactured
to provide excellent performance and service. To ensure
that your equipment will continue to perform as intend-
ed:
• Maintain equipment regularly- following the sug-
gested maintenance schedule provided.
• Use only original OEM parts when servicing.
• Operate equipment with care.
If additional information is needed, please contact
CLEANFREAK at: 800.826.4405
All information and specications printed in the manual
are current at the time of printing; however because of
CLEANFREAK’s policy of continual product develop-
ment, we reserve the right to make changes at any time
without notice.
FAILURE TO COMPLY WITH THE FOL-
LOWING WARNINGS AND INSTRUC-
TIONS WILL VOID THE WARRANTY.
WARNING!
• Make sure the machine is plugged into an electrical
outlet with the same voltage and frequency rating as
shown on the nameplate of the machine. Do not at-
tempt to plug a 115 volt machine into a 230 volt outlet.
• Do not immerse or use this machine in standing wa-
ter. Such use can cause electric shock.
• Do not use to pick up ammable or combustible liq-
uids such as gasoline or use in areas where they may
be present.
• Do not expose machine to freezing temperatures.
• To avoid electric shock, do not expose the unit to
rain- store indoors only.
• Connect to a properly grounded outlet only. See
“Grounding Instructions.”
• Turn o all controls before unplugging.
• Do not use without lters in place.
• Do not put any object into openings. Do not use with
any opening blocked; keep free of dust, lint, hair and
anything that may reduce air ow.
• Do not pick up anything that is burning or smoking,
such as cigarettes, matches or hot ashes.
• Do not use machine for dry vacuuming. is machine
is not outtted with a ne dust lter and it will dam-
age the vacuum motor( s ).
• All servicing of CLEANFREAK equipment should be
performed only by CLEANFREAK authorized ser-
vice centers.
• Keep hair, loose clothing, ngers an all parts of the
body away from openings and moving parts.
• Use extra care when cleaning on or around stairs.
• Do not use replacement parts other than those spec-
ied in the parts list. Proper function of the machine
could be aected if substitutions are made.
• Follow maintenance schedule strictly.
2

GROUNDING INSTRUCTIONS:
is piece of equipment must be grounded. Should an
electrical malfunction occur, grounding provides a path
of least resistance for electrical current- reducing the risk
of electric shock. is piece of equipment is furnished
with a cord that has a grounding conductor and ground-
ing plug. e grounded plug must only be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
Connecting the equipment to an improperly grounded
outlet can result in an increased risk of electric shock. A
qualified electrician should be consulted if you are un-
sure that the outlet is properly grounded. Do not modify
the plug provided with the equipment. If it will not fit
the outlet, have a proper outlet installed by a qualified
electrician.
is appliance is designed for use on a 120-volt circuit.
e grounding plug provided looks like the plug illus-
trated in Figure 1. Replace the power cord if the ground-
ing pin is damaged or broken.
DAILY MAINTENANCE:
e TPL-PH12 is engineered and built to require mini-
mum maintenance. But like any machine, it does require
some care to keep it in optimum working condition.
Careful attention to these maintenance instructions
will give you maximum operating performance and life
expectancy of the machine.
CAUTION: Disconnect the power cord from the out-
let before doing any clean up or maintenance on the
machine
1. Keep the machine clean, inside and out including
brush and brush chamber.
2. Pour a gallon of clean hot water into your extractor.
Tum the pump on and ush the entire system
through the spray nozzles for about a minute to pre-
vent alkaline build-up.
3. Quick connect coupler- Spray with silicone lubricant
to keep coupler from sticking.
4. If the plunger on the valve sticks, disassemble and
spray with silicone lubricant.
Servicing:
In the event that your heater requires service, please
contact CLEANFREAK at:
800.826.4405
Do not attempt major repairs yourself. CLEANFREAK
will assist you in locating an indepedent service contrac-
tor.
Fig. 1
3

CLEANING TIPS
• Check the condition of the area to be cleaned. Look
for loose carpet, heavily soiled areas, stains or spots
and worn areas. Bring these to the attention of the
person in charge before performing the cleaning job.
Make sure all edges of the carpet are securely tacked
in place and all seams are sewn ( or glued) tight. is
is your protection against shrinkage.
• Locate an inconspicuous spot on the area to be
cleaned. Test carpet for colorfastness before pro-
ceeding. Pour the concentrated cleaning solution on
the spot, cover with a white towel and place a heavy
object on top to absorb the cleaning solution. Wait
approximately 10 minuets for any reaction to take
place. Remove weight. If there is no color transfer, it
should be safe to clean. Apply this procedure if dif-
ferent color-texture carpet is seen in adjacent rooms
or areas to be cleaned.
• Remove the furniture from the area to be cleaned.
Large pieces can be moved to opposite end of the
room from where you start cleaning and replaced
when it is completed. Aer cleaning carpet, place a
small square of aluminum foil under the furniture
legs to prevent moisture from damaging the nish
and avoid dye and rust from transferring to the car-
pet.
• Clean the area with an upright vacuum. DO NOT
USE THIS MACHINE AS A DRY VACUUM! Heav-
ily soiled carpet or areas of concentrated foot trac
should be treated with recommended pre-spotting
or pre-spray chemicals. If a spotter is used, follow
label directions exactly. Do not allow any spotter or
prespray to dry on the carpet as it may damage the
carpet permanently.
• Identify the type of carpet ber to be cleaned. Most
commercial carpet bers in use are acrylic or nylon
based. Best results in cleaning would be obtained if
hot water is used to clean these bers. On the other
hand, hot water would shrink natural ber carpet-
ing, like wool and cotton in particular. Exercise
caution when cleaning natural bers by using cool
water, testing for colorfastness and applying the least
amount of cleaning solution possible.
• Plan your cleaning route. Start cleaning at the far-
thest point away from where you plugged the ma-
chine and work back towards the outlet so that the
cord will not get in the way.
TO CLEAN CARPET:
1. Prepare your carpet extractor as necessary.
2. Slide the vacuum hose cu over the tube end of the
wand handle.
3. Connect the male brass tting on your solution hose
to the female brass tting on the TPL-PH12.
4. Plug the power cord to an approved wall plug recep-
tacle.
5. To clean, depress wand lever while pulling back on
the power wand. make overlapping passes to prevent
streaking.
6. If necessary, make a dry pass (no solution spray)
over the path you just cleaned with the brush still on,
to remove as much dirt and solution as possible.
4

5
TPL-PH12 BREAKDOWN
FOR UNITS MANUFACTURED
PRIOR TO
JUNE 15, 2016.
FOR UNITS MANUFACTURED
AFTER JUNE 15, 2016 SEE
HANDLE RETROFIT
ON PAGE 7.

6
ITEM
NO.
PART NUMBER QTY.
ITEM
NO.
PART NUMBER QTY.
1UNAVAILABLE 0 29 D00356-4 WEIGHT BLOCK 1
2UNAVAILABLE. SEE #5 0 30 A00091-2 SPRAY TIP 1
3UNAVAILABLE 0 31 00185-6A WIRING ASSY. 1
4 H00564-2 WARNING LABEL 1 32 B00190 4" ZIP TIE 1
5G11603-1 PRESSURE VALVE 1 33 E03428 MOTOR SEAL GASKET 1
6UNAVAILABLE 0 34 G00539 BRUSH MOTOR 1
8 J00651 HOSE CLAMP 1 35 A00102 Q.D. 1/4F X 1/4FP 1
9 02494-1A CORD HOOK ASSY. 1 36 A00053 45 ELBOW 1/4MP X 1/4FP 1
10 02382A HANDLE RETROFIT KIT 1
11 00580-36IN-A HP HOSE ASSY 1
12 C00311 8-32 X 3/8 RH 25
13 B00216 POWER CORD 1
14 UNAVAILABLE
15 B02211-1 ROCKER SWITCH 1
16 G02531-1 WHEEL 4" 2
17 82331-2A AXLE ASSEMPLY 1
18 C00312-1 10-32 X 1 1/8" BLK ZINC 2
19 B02212 STRAIN RELIEF W/ NUT 1
20 82490A-GREY MOTOR HOUSING 1
21 82491A SUCTION HEAD LENS 1
22 F02492-GREY BOTTOM COVER 1
23 F02493-GREY BELT ACCESS COV. 1
24 82363A MOTOR STRAP ASSY 2
25 82424A BEARING SHAFT ASSY. 1
26 G00528-3 BRUSH BEARING 2
27 80508-1A BRUSH ASSY 1
28 E02445 BELT 1

7
1. A00102 Female Q.D. 1/4F to 1/4FP
2.A00168-18 Brass Bushing 1/4M x 1/8F
3. 11527A-PW 1/8 High Pressure Hose Assy
4. G13658 Valve With Bracket
5. A00114B Hex Nipple 1/4MP X1/8MP
6. A12964 1/4 brass coupler
7. D02382
7. D02382 Wand Handle
7
6
5
02382A Retrooit kit

8

9
Table of contents
Other CleanFreak Scrubber manuals