Cleode ZigBee ZPILOT User manual

S.A. au capital de 167 200 €
R.C.S. Saint Brieuc TGI 450 570 767
Siège social : 8 rue Bourseul 22300 Lannion France
Tél. : +33 (0) 2 96 48 68 18 – Fax : +33 (0) 2 96 48 19 11
Command of electric heater by
wire pilot ZigBee™
ZPILOT
User Man al
Revision: 1.0
Document: UM_ZPILOT_20120903_001_01_00

S.A. au capital de 167 200 €
R.C.S. Saint Brieuc TGI 450 570 767
Siège social : 8 rue Bourseul 22300 Lannion France
Tél. : +33 (0) 2 96 48 68 18 – Fax : +33 (0) 2 96 48 19 11
WARRANTY
The device supplied to the buyer and/or the recipient is guaranteed by CLEODE against any
malfunctions originating from a design and/or manufacturing flaw, for a period of twelve (12)
months following delivery. The buyer and/or recipient is (are) responsible for proving the
existence of the said defects or flaws. This warranty is applicable in accordance with articles
1641 to 1648 of the French Civil Code and in compliance with the French statutory warranty.
The warranty covers the replacement free of charge of devices and parts affected by a design
and/or manufacturing flaw excluding conspicuous defects in the device that are covered by
the buyer and/or the recipient.
In order to invoke the warranty, the buyer must immediately send written notice to CLEODE
of the flaws that it attributes to the device. It must enable CLEODE to have access to the
device to observe these defects and repair them. The warranty provided by CLEODE is
strictly limited to the equipment provided and shall only have for effect the replacement or
repair, at CLEODE’s expense, on its own premises, of all devices or parts that are not
functioning as a result of defects or flaws. CLEODE reserves the right to modify the devices
in order to comply with the warranty.
The warranty does not apply to replacement or repairs that may result from normal wear and
tear of devices, systems or products, damage or accidents resulting from negligence, failure to
supervise or maintain, or incorrect use of the devices, systems and/or products.
The maintenance service is provided by CLEODE with all reasonable care possible and in
compliance with the current state of the arts.
The exchange of parts or repairs performed under the warranty cannot result in extending the
length of the warranty. In no event can the unavailability of the device due to servicing give
rise to compensation for any reason whatsoever. The seller is released from all obligations
relating to the warranty if the product or device has been modified without prior written
consent, or if original parts have been replaced by parts which it has not manufactured
without prior consent. If unforeseen damage is caused by the device, it is expressly agreed
that the seller can only be liable for the reimbursement of monies received for the purchase of
the device if it has been destroyed. Under no circumstances can the seller be held liable for
indirect or contingent damage. The seller is released from any liability and the buyer waives
any rights against it if an accident or direct or indirect damage is caused to the buyer
following a defect, incorrect usage, incorrect maintenance or normal wear of the device sold.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 3 sur 17
TABLE OF CONTENT
WARRANTY......................................................................................................................................... 2
TABLE OF REVISIONS...................................................................................................................... 4
REFERENCE DOCUMENTS ............................................................................................................. 5
IINTRODUCTION ........................................................................................................................... 6
I.1 COMMAND OF ELECTRIC HEATER BY WIRE PILOT ZIGBEE™PRESENTATION ........................ 6
I.2 COPYRIGHT ................................................................................................................................... 6
II ZPILOT DESCRIPTION.............................................................................................................. 7
II.1 ZIGBEE PRESENTATION .............................................................................................................. 7
II.2 HEATING UNIT APPLICATION ..................................................................................................... 7
II.2.1 HEATING UNIT APPLICATION DESCRIPTION ............................................................................... 7
II.2.2 CLUSTERS DESCRIPTION ............................................................................................................. 8
III INSTALLATION AND NETWORK ASSOCIATION .......................................................... 11
III.1 INSTALLATION.......................................................................................................................... 11
III.1.1 DOUBLE-SIDED TAPE INSTALLATION ...................................................................................... 11
III.1.2 CONNECTING........................................................................................................................... 11
III.2 STARTING UP ZPILOT............................................................................................................ 13
III.3 RESTART OF THE ASSOCIATION PHASE .................................................................................. 13
III.4 RESET........................................................................................................................................ 14
TECHNICAL FEATURES ................................................................................................................ 15
REPAIR AND MAINTENANCE ...................................................................................................... 16

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 4 sur 17
TABLE OF REVISIONS
Version Authors(s) Version description Date
0.1
CLEODE
Initial version
27/08/2012
1.0 CLEODE Validated document 03/09/2012

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 5 sur 17
REFERENCE DOCUMENTS
N°
Document
Descript
ion
[1]
ZigBee_Cluster_Library_Public
Spécification de la Zigbee Cluster Library
[2] ZigBee_Home_Automation_Profile
Spécification du profile Home Automation
[3] ZigBee_Specification Spécification de la norme ZigBee

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 6 sur 17
I INTRODUCTION
I.1 Command of electric heater by wire pilot ZigBee™ presentation
The system of command of electric heater by wire pilot ZPILOT allows commanding electric
heater.
The ZPILOT also integrates the function of router ZigBee ™.
The ZPILOT has this form:
The module ZPILOT works in conjunction with a Zigbee coordinator ™
compatible stack pro 2007.
CLEODE also markets Coordinators Zigbee™.
I.2 Copyright
The CLEODE trademark and the CLEODE logo are properties of CLEODE SA, France. This
document also refers to trademarks and other product names that are registered trademarks of
their respective owners.
Copyright © 2009 CLEODE SA. All rights reserved.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 7 sur 17
II ZPILOT DESCRIPTION
II.1 ZigBee presentation
The system of command of electric heater ZigBee™ contains application type Heating unit
defined in the standard Home Automation (Cf. document [2]).
This node is fully compliant with the ZigBee™ PRO 2007 and Home Automation profile. For
more detail on the data exchange between device and network, see documents [1], [2] and [3].
II.2 Heating unit application
The system of command of electric heater allows to emit 6 orders following the heaters
electric:
-Comfort
-Comfort – 1 °C
-Comfort – 2°C
-Economic
-Frost protection
-Off
II.2.1 Heating unit application description
Device ID: On/Off output
Endpoint number: 1
Clusters:
Server
Client
Basic (0x0000)
/
Identify (0x0003)
/
Groups (0x0004) /
Scenes (0x0005) /
On/Off (0x0006) /
Pilot Control (0xFC01) /

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 8 sur 17
II.2.2 Clusters description
This is a terse description of clusters and attributes which are implemented in the ZPILOT.
For more detail on these, see document [1].
Basic cluster :
This cluster is used to determine basic information about the device.
Attribute
Attribute ID
ZCLVersion
0x0000
ApplicationVersio
n
0x0001
StackVersion 0x0002
HWVersion 0x0003
ManufacturerName 0x0004
ModelIdentifier 0x0005
DateCode
0x0006
PowerSource
0x0007
LocationDescription
0x0010
PhysicalEnvironment 0x0011
DeviceEnabled 0x0012
AlarmMask 0x0013
Identify cluster :
This cluster is used to put a device into an identification mode. By writing the
IdentifyTime attribute value, the user asks the device to blink the light, during a number of
seconds specified by this value.
Attribute Attribute ID
IdentifyTime 0x0000
Cluster Groups:
This cluster allows storing the name of the groups to which the ZPILOT belongs.
Attribute Attribute ID
NameSupport 0x0000

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 9 sur 17
Cluster Scenes:
This cluster allows managing the scenes of which are a part the ZPILOT.
Attribute Attribute ID
SceneCount 0x0000
CurrentScene 0x0001
CurrentGroup 0x0002
SceneValid 0x0003
NameSupport 0x0004
On/Off cluster:
This cluster is used to switching the device between ON and OFF states.
Attribute Attribute ID
On/Off
0x0000
When this attribute value is ON, the last used mode is emitted on the wire pilot. The value
OFF emits the mode OFF on the wire pilot.
Pilot Control :
This cluster is used to change the mode on the wire pilot.
Attribute Attribute ID
Mode 0x0000
The attribute Mode allows to know the order emitted on the wire pilot.
This cluster is a cluster owner to the company CLEODE. To modify this value, the
writing must be made by using to manufacture code CLEODE = 0x10B9.
The attribute Mode can take the following values:
Mode Values
Comfort 0x00
Comfort – 1°C 0x01
Comfort – 2°C 0x02
Economic
0x03
Frost protection
0x04
OFF 0x05

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 10 sur 17
It is possible to modify the value mode by writing or by sending the SET_MODE
command corresponding to the value 0x00 followed by the mode in which you wish to
place your electric heater.
So that the mode is taken into account by the ZPILOT the value of the cluster ON/OFF
must be put to ON.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 11 sur 17
III INSTALLATION AND NETWORK ASSOCIATION
III.1 Installation
III.1.1 Double-sided tape installation
To mount the ZPILOT with a double-sided tape, follow this:
1) Stick a double-sided tape on the ZPILOT bottom
2) Dust the wall
3) Mount the ZPILOT on the wall
III.1.2 Connecting
To connect the ZPILOT, follow the procedure this below.
Connect the supply of the ZPILOT as indicated below.
Attention: Shut down the power supply before any intervention and it till the end
the manipulations.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 12 sur 17
Connect the wire pilot on the ZPILOT.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 13 sur 17
III.2 Starting up ZPILOT
In the switched on of the object, it tries to
join during about seconds and flashes
twice.
If a coordinator is present and what it
authorizes the ZPILOT to join the network,
the light of the ZPILOT flashing during 2
seconds then turn off.
In the cases where the association is not possible, the object is going to put itself in sleep and
to try automatically to join at the end of 15 minutes. This time will increase twofold in every
new failure of the association.
III.3 Restart of the association phase
If the ZPILOT is not associated, the user can ask him at any time to join a network.
For this, the user has to press during 3
seconds on the button.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 14 sur 17
If the ZPILOT was not associated it begins
flashing quickly during 20 seconds. The
ZPILOT looks for a coordinator during this
blinking.
If the association is success, the light of the
ZPILOT flashing during 2 seconds and turn
off.
If the light of the ZPILOT does not flash after to have press on the button during 3 seconds, this
means that he is already associated in a network.
III.4 Reset
If need, the user can reset of the ZPILOT.
For this, he has to press on the button during
5 seconds.
When the ZPILOT reset, the LED flashes
twice and turn off.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 15 sur 17
TECHNICAL FEATURES
Weight
100
g
Power supply
220V
Measurement 54 x 52 x 32 mm
Transmission range 100 m outdoor
30 m indoor
Managed channels (frequency) 16 ZigBee™ channels (2.405 to 2.480 GHz)

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 16 sur 17
REPAIR AND MAINTENANCE
Defective equipments shall be first reported to the CLEODE support team in order to be
assigned an RMA number. Be prepared to state your name, company and the serial number of
the defective item to the support personnel.
The item shall then be returned to CLEODE with the following documents:
The RMA number
A copy of the delivery slip
A detailed description of the default and the test context
The maintenance period is typically four (4) weeks starting from the date of reception of the
equipment at the CLEODE headquarters.

Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00 CLEODE Page 17 sur 17
CLEODE S.A.
Technical Support Division
8, rue Bourseul
22300 Lannion
France
Phone : +33 (0) 2 96 48 68 18
Fax : +33 (0) 2 96 48 19 11
E-mail : support@cleode.com
Web : http://www.cleode.com
Table of contents
Other Cleode Control System manuals
Popular Control System manuals by other brands

Evco
Evco EVJS 500 Split Installer manual

Roger Technology
Roger Technology H70 Series INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

CSP Pacific
CSP Pacific SENTRY BARRIER MASH TL-4 Product and installation manual

Eaton
Eaton CCS 5 instruction manual

Electronics Line
Electronics Line iconnect installation manual

Velux
Velux KFX 210 instructions