Cleode ZigBee ZLOCK User manual

S.A. au capital de 167 200 €
R.C.S. Saint Brieuc TGI 450 570 767
Siège social : 8 rue Bourseul 22300 Lannion France
Tél. : +33 (0) 2 96 48 68 18 – Fax : +33 (0) 2 96 48 19 11
ZigBee™
command of door lock
ZLOCK
User Manual
Revision: 1.0
Document: UM_ZLOCK_20110919_001_01_00.doc

S.A. au capital de 167 200 €
R.C.S. Saint Brieuc TGI 450 570 767
Siège social : 8 rue Bourseul 22300 Lannion France
Tél. : +33 (0) 2 96 48 68 18 – Fax : +33 (0) 2 96 48 19 11
WARRANTY
The device supplied to the buyer and/or the recipient is guaranteed by CLEODE against any
malfunctions originating from a design and/or manufacturing flaw, for a period of twelve (12)
months following delivery. The buyer and/or recipient is (are) responsible for proving the
existence of the said defects or flaws. This warranty is applicable in accordance with articles
1641 to 1648 of the French Civil Code and in compliance with the French statutory warranty.
The warranty covers the replacement free of charge of devices and parts affected by a design
and/or manufacturing flaw excluding conspicuous defects in the device that are covered by
the buyer and/or the recipient.
In order to invoke the warranty, the buyer must immediately send written notice to CLEODE
of the flaws that it attributes to the device. It must enable CLEODE to have access to the
device to observe these defects and repair them. The warranty provided by CLEODE is
strictly limited to the equipment provided and shall only have for effect the replacement or
repair, at CLEODE’s expense, on its own premises, of all devices or parts that are not
functioning as a result of defects or flaws. CLEODE reserves the right to modify the devices
in order to comply with the warranty.
The warranty does not apply to replacement or repairs that may result from normal wear and
tear of devices, systems or products, damage or accidents resulting from negligence, failure to
supervise or maintain, or incorrect use of the devices, systems and/or products.
The maintenance service is provided by CLEODE with all reasonable care possible and in
compliance with the current state of the arts.
The exchange of parts or repairs performed under the warranty cannot result in extending the
length of the warranty. In no event can the unavailability of the device due to servicing give
rise to compensation for any reason whatsoever. The seller is released from all obligations
relating to the warranty if the product or device has been modified without prior written
consent, or if original parts have been replaced by parts which it has not manufactured
without prior consent. If unforeseen damage is caused by the device, it is expressly agreed
that the seller can only be liable for the reimbursement of monies received for the purchase of
the device if it has been destroyed. Under no circumstances can the seller be held liable for
indirect or contingent damage. The seller is released from any liability and the buyer waives
any rights against it if an accident or direct or indirect damage is caused to the buyer
following a defect, incorrect usage, incorrect maintenance or normal wear of the device sold.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 3 sur 16
TABLE OF CONTENT
WARRANTY ......................................................................................................................................... 2
TABLE OF REVISIONS ...................................................................................................................... 4
REFERENCE DOCUMENTS ............................................................................................................. 5
IINTRODUCTION ........................................................................................................................... 6
I.1 ZIGBEE COMMAND OF DOOR LOCK PRESENTATION................................................................... 6
I.2 COPYRIGHT ................................................................................................................................... 6
II ZLOCK DESCRIPTION .............................................................................................................. 7
II.1 ZIGBEE PRESENTATION .............................................................................................................. 7
II.2 DOOR LOCK APPLICATION.......................................................................................................... 7
II.2.1 DOOR LOCK APPLICATION DESCRIPTION .................................................................................... 7
II.2.2 CLUSTERS DESCRIPTION ............................................................................................................. 8
III INSTALLATION AND NETWORK ASSOCIATION .......................................................... 10
III.1 INSTALLATION.......................................................................................................................... 10
III.1.1 DOUBLE-SIDED TAPE INSTALLATION ...................................................................................... 10
III.1.2 RACCORDEMENT ..................................................................................................................... 10
III.2 STARTING UP ZLOCK ............................................................................................................ 12
III.3 RESTART OF THE ASSOCIATION PHASE .................................................................................. 12
III.4 RESET........................................................................................................................................ 13
IV TECHNICAL FEATURES........................................................................................................ 14
REPAIR AND MAINTENANCE ...................................................................................................... 15

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 4 sur 16
TABLE OF REVISIONS
Version Authors(s) Version description Date
0.1 CLEODE Initial version 15/09/2011
1.0 CLEODE Validated document 22/09/2011

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 5 sur 16
REFERENCE DOCUMENTS
N° Document Description
[1] ZigBee_Cluster_Library_Public Spécification de la Zigbee Cluster Library
[2] ZigBee_Home_Automation_Profile
Spécification du profile Home Automation
[3] ZigBee_Specification Spécification de la norme ZigBee

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 6 sur 16
I INTRODUCTION
I.1 ZIGBEE COMMAND OF DOOR LOCK PRESENTATION
The system of command of door lock ZLOCK allows commanding door lock.
The ZLOCK also integrates the function of router ZigBee ™.
The ZLOCK has this form:
The module ZLock works in conjunction with a Zigbee coordinator ™ compatible
stack pro 2007.
CLEODE also markets Coordinators Zigbee™.
I.2 COPYRIGHT
The CLEODE trademark and the CLEODE logo are properties of CLEODE SA, France. This
document also refers to trademarks and other product names that are registered trademarks of
their respective owners.
Copyright © 2009 CLEODE SA. All rights reserved.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 7 sur 16
II ZLOCK DESCRIPTION
II.1 ZIGBEE PRESENTATION
The system of command of door lock ZigBee ™ contains application type Door Lock defined
in the standard Home Automation (Cf. document [2]).
This node is fully compliant with the ZigBee™ PRO 2007 and Home Automation profile. For
more detail on the data exchange between device and network, see documents [1], [2] and [3].
II.2 DOOR LOCK APPLICATION
The system of command of door lock allows feed the exit in 12V or 24V, according to the
power supply, used to free the door lock. This application is a part of the profile Home
Automation.
II.2.1 DOOR LOCK APPLICATION DESCRIPTION
Device ID : Door Lock
Endpoint number: 1
Clusters :
Server Client
Basic (0x0000) /
Identify (0x0003) /
Groups (0x0004) /
Scenes (0x0005) /
Door Lock (0x0101) /

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 8 sur 16
II.2.2 CLUSTERS DESCRIPTION
This is a terse description of clusters and attributes which are implemented in the ZLOCK.
For more detail on these, see document [1].
Basic cluster :
This cluster is used to determine basic information about the device.
Attribute Attribute ID
ZCLVersion 0x0000
ApplicationVersion 0x0001
StackVersion 0x0002
HWVersion 0x0003
ManufacturerName 0x0004
ModelIdentifier 0x0005
DateCode 0x0006
PowerSource 0x0007
LocationDescription 0x0010
PhysicalEnvironment 0x0011
DeviceEnabled 0x0012
AlarmMask 0x0013
Identify cluster :
This cluster is used to put a device into an identification mode. By writing the
IdentifyTime attribute value, the user asks the device to blink the light, during a number of
seconds specified by this value.
Attribute Attribute ID
IdentifyTime 0x0000
Cluster Groups:
This cluster allows storing the name of the groups to which the ZLOCK belongs.
Attribute Attribute ID
NameSupport 0x0000

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 9 sur 16
Cluster Scenes:
This cluster allows managing the scenes of which are a part the ZLOCK.
Attribute Attribute ID
SceneCount 0x0000
CurrentScene 0x0001
CurrentGroup 0x0002
SceneValid 0x0003
NameSupport 0x0004
Door Lock :
This cluster allows knowing the characteristics of the ZLOCK.
Attribut Identifiant de l’attribut
Lock State 0x0000
Lock Type 0x0001
Actuator Enable 0x0002
The attribute Lock State allows knowing if the striking plate is locked or not.
The attribute Lock Type allows to know the type of used door lock, in the case of the
ZLOCK it costs 0x00 (DEAD BOLT).

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 10 sur 16
III INSTALLATION AND NETWORK ASSOCIATION
III.1 INSTALLATION
III.1.1 DOUBLE-SIDED TAPE INSTALLATION
To mount the ZLOCK with a double-sided tape, follow this:
1) Stick a double-sided tape on the ZLOCK bottom
2) Dust the wall
3) Mount the ZLOCK on the wall
III.1.2 RACCORDEMENT
To connect the ZLOCK, follow the procedure this below.
Connect the supply of the ZLOCK as indicated below.
Attention: Shut down the power supply before any intervention and it till the end
the manipulations.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 11 sur 16
Connect the door lock on the ZLOCK.
Attention: a single door lock must be connected by ZLOCK.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 12 sur 16
III.2 STARTING UP ZLOCK
In the switched on of the object, it tries to
join during about seconds and flashes
twice.
If a coordinator is present and what it
authorizes the ZLOCK to join the network,
the light of the ZLOCK flashing during 2
seconds then turn off.
In the cases where the association is not possible, the object is going to put itself in sleep and
to try automatically to join at the end of 15 minutes. This time will increase twofold in every
new failure of the association.
III.3 RESTART OF THE ASSOCIATION PHASE
If the ZLOCK is not associated, the user can ask him at any time to join a network.
For this, the user has to press during 3
seconds on the button.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 13 sur 16
If the ZLOCK was not associated it begins
flashing quickly during 20 seconds. The
ZLOCK looks for a coordinator during this
blinking.
If the association is success, the light of the
ZLOCK flashing during 2 seconds and turn
off.
If the light of the ZLOCK does not flash after to have press on the button during 3 seconds, this
means that he is already associated in a network.
III.4 RESET
If need, the user can reset of the ZLOCK.
For this, he has to press on the button during
5 seconds.
When the ZLOCK reset, the LED flashes
twice and turn off.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 14 sur 16
IV TECHNICAL FEATURES
Weight 100 g
Power supply Max. 24V
Commutation Max. 3A
Measurement 54 x 52 x 32 mm
Transmission range 100 m outdoor
30 m indoor
Managed channels (frequency) 16 ZigBee™ channels (2.405 to 2.480 GHz)

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 15 sur 16
REPAIR AND MAINTENANCE
Defective equipments shall be first reported to the CLEODE support team in order to be
assigned an RMA number. Be prepared to state your name, company and the serial number of
the defective item to the support personnel.
The item shall then be returned to CLEODE with the following documents:
The RMA number
A copy of the delivery slip
A detailed description of the default and the test context
The maintenance period is typically four (4) weeks starting from the date of reception of the
equipment at the CLEODE headquarters.

ZigBee command of door lock – User Manual
UM_ZLOCK_20110919_001_01_00 CLEODE Page 16 sur 16
CLEODE S.A.
Technical Support Division
8, rue Bourseul
22300 Lannion
France
Phone : +33 (0) 2 96 48 68 18
Fax : +33 (0) 2 96 48 19 11
E-mail : support@cleode.com
Web : http://www.cleode.com
Table of contents
Other Cleode Control System manuals
Popular Control System manuals by other brands

igus
igus drylin dryve D3 manual

DELTA DORE
DELTA DORE TYXIA 6410 manual

Airzone
Airzone VAF BLUEFACE Quick installation guide

A-T Controls
A-T Controls TRIAO TMC-4 Installation and operation manual

Firestone
Firestone 2491 installation instructions

Hans Grohe
Hans Grohe Pontos Base Usage instructions / installation manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries SC-SL4-AE installation manual

Woodward
Woodward EGCP-2 to easYgen-3200XT instruction manual

cinetto
cinetto B-MOVED Quick start installation and setup guide

Norac
Norac UC4.5 installation manual

Skov
Skov BlueControl 20RL Technical user guide

Nidec
Nidec Control Techniques HVAC Drive H300 HMI... Installation and commissioning guide