Clever Acoustics MA 4120 MKII User manual

MA 4120 MKII 480W
4 Zone Mixer Amplier
User Manual
Order code: CRAM33
MA 4120 MKII Mixer Amplier
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 1
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 2
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 3
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 4
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 5
-10 +10
-10 +10
-10 +10
010
PHONE
PHONE
VOLUME
MONITOR
VOLUME
010
VOLUME
ZONE 3
MONITOR
0
1
2
3
456
7
8
9
10
ZONE 1 ZONE 2
ZONE 4
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
ON
OFF
POWER
0
1
2
3
456
7
8
9
10
CH4 CH2
CH1CH3
L
R
CH5
LINE
POWER INPUT:
110-240V~50/60Hz
110-120V~60Hz - FUSE: T12A 250V
220-240V~50/60Hz - FUSE: T6.3A 250V
SERIAL NUMBER
www.cleveracoustics.co.uk
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN. NO USER
SERVICABLE PARTS INSIDE
MONITOR
LINE OUTPUT
G +
MONITOR
1W 8Ω
PRIORITY
– +
TEL PAGING
COM GNDHOT
110-120V~ 220-240V~
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
TEL
VOLUMEZONE
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 1 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 2 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 3 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 4 G – +
POWER CONSUMPTION (max.): 550W

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltage
isbetween240V,50HzAC.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProlight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Threeyearsfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
3
Product overview & technical specications
TheMA4120MKII4ZoneMixerAmplierisidealforsystemswheremultiplezonesarerequired.Designedfor
useinvenuessuchasschools,churches,entertainmentvenuesorcommercialbuildings,theMA4120MKII
offersmultizoneaudioroutingcoupledwithfourindependent120Wrmsampliers.TheMA4120MKII4zone
mixeramplierhasveinputchannels,eachwithselectableindependentoutputrouting,inputgain,treblebass
andvolumecontrols.Inputchannels1thru4areviaXLR/Jackcombosockets,eachwithLine/Mic/Mic+Phantom
selection,inputchannel5isviaastereolinelevelinput.
FouroutputzoneseachfeatureLEDVUindicators,monitorselectionandvolumecontrolswithoutputsforline
level,lowimpedance(4-8Ω)andconstantvoltagespeakersystems(25V,75V&100V).Theon-boardmonitor
facility,selectableforeachzoneoutputfeaturesbothalinelevelaudioand1W8Ωloudspeakeroutputsuitablefor
drivingaloudspeakerlocaltotheMA4120MKIIzonemixer.
•Fouroutputzoneseachwithlevelcontrolandmonitorselection
•Fourindependent120Wrmsamplifiersoutputtingto4-8Ωor25,70,100V
•Fiveinputchannels:
Channels1-4areviaXLR/Jackcombosockets,
eachwithLine/Mic/Mic+Phantomselection(48V)
Channels5isviaphono(RCA)stereolinelevelinput
•3U,19”rackmountchassis
•Inputgain,treble,bassandlevelcontrols
•Selectableoutputroutingforallinputchannels
•MonitorfunctionwithlevelcontrolandLEDVUmeter
•Outputformonitorloudspeaker:1W,8Ω
•Headphoneoutputwithlevelcontrol
•Telephone/paginginput(zoneselectable)withadjustablelevel
•Prioritycontactformusicmutefacility(CH4and5mute,CH1-3priority)
•VOXoperatedpriorityforTELinput
•CH1inputautomaticVOXpriority(internaljumperforpriorityoverride)
•TelephoneandMIC1(musicmutefacility)
•Inputchannelmuteswitchesonfrontpanel
•LinelevelMIXoutput
•Temperaturecontrolled,variablespeedfancooling
MA 4120 MKII 480W 4 Zone Mixer Amplier
MA 4120 MKII Mixer Amplier
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 1
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 2
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 3
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 4
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 5
-10 +10
-10 +10
-10 +10
010
PHONE
PHONE
VOLUME
MONITOR
VOLUME
010
VOLUME
ZONE 3
MONITOR
0
1
2
3
456
7
8
9
10
ZONE 1 ZONE 2
ZONE 4
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
ON
OFF
POWER
0
1
2
3
456
7
8
9
10
CH4 CH2
CH1CH3
L
R
CH5
LINE
POWER INPUT:
110-240V~50/60Hz
110-120V~60Hz - FUSE: T12A 250V
220-240V~50/60Hz - FUSE: T6.3A 250V
SERIAL NUMBER
www.cleveracoustics.co.uk
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN. NO USER
SERVICABLE PARTS INSIDE
MONITOR
LINE OUTPUT
G +
MONITOR
1W 8Ω
PRIORITY
– +
TEL PAGING
COM GNDHOT
110-120V~ 220-240V~
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
TEL
VOLUMEZONE
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 1 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 2 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 3 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 4 G – +
POWER CONSUMPTION (max.): 550W
Specications MA 4120 480W Mixer Amplier
Poweroutput 4x120Wrms(4x240Wpeak)
Speakeroutputs 25V,70V,100Vand4-8Ω
Sensitivity -CH1–4:—50dB(Mic/Phantom),
-10dB(Line)
-CH5:-10dB(unbalanced)
Frequencyresponse 60Hz-17kHz(±3dB)
Tonecontrol ±10dB-100Hz/±10dB-10kHz
(bass/treble)
S/Nratio >65dB(Mic),>75dB(Line),
>65dB(TEL)
THD <1%(@1kHz1Woutput)
Powerconsumption 550W(max.)
Powersupply 110-240V~50/60HzAC
Fuse T6.3A250V
Dimensions 135x484x395mm
Weight 22kg
Ordercode CRAM33
Z1
Z3
Z2
Z4
CH 1
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
Z3
Z2
Z4
CH 2
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
Z3
Z2
Z4
CH 3
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
Z3
Z2
Z4
CH 4
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
Z3
Z2
Z4
CH 5
0
1
2
3
456
7
8
9
100
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
010
PHONE
PHONE
VOLUME
MONITOR
VOLUME
010
VOLUME
ZONE 3
MONITOR
0
1
2
3
456
7
8
9
10
ZONE 1 ZONE 2
ZONE 4
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
ON
OFF
POWER
LF
HF
GAIN
LF
HF
GAIN
LF
HF
GAIN
LF
HF
GAIN
LF
HF
GAIN
MUTE MUTE MUTE MUTEMUTE
VOL VOL VO L VOL VOL
MA 4120 MKII Mixer Amplier
135mm
484mm 395mm

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
4
Panel & connection identication
01-Gaincontrol
02-HFlevelcontrol
03-LFlevelcontrol
04-Muteswitch
05-MuteLED
06-Inputchannellevelcontrol
07-Zoneselectionswitches
08-Headphonelevelcontrol
09-Headphoneoutput
10-LEDVUoutputmeter
11-Monitorlevelcontrol
12-Zoneoutputlevelcontrol
13-Monitoroutputselector
14-PowerLED
15-Powerswitch
16-Coolingfan
17-ACmainspowerinput
18-ACmainsfuse
19-ACvoltageselector
20-Monitor(MIX)lineoutput
21-Monitorloudspeakeroutput
(1W8Ω)
22-Prioritycontrolterminals
23-Telephone/paginginput(TEL)
24-Telephone/paginginput
zoneselection&volumecontrol
25-StereoLINEinputs
26-MonoMIC/LINEinputs
27-Inputsensitivityandphantom
powercontrol
28-Balancedlinelevelzoneoutputs
29-Poweramplieroutputs
MA 4120 MKII Mixer Amplier
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 1
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 2
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 3
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 4
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 5
-10 +10
-10 +10
-10 +10
010
PHONE
PHONE
VOLUME
MONITOR
VOLUME
010
VOLUME
ZONE 3
MONITOR
0
1
2
3
456
7
8
9
10
ZONE 1 ZONE 2
ZONE 4
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
ON
OFF
POWER
0
1
2
3
456
7
8
9
10
CH4 CH2
CH1CH3
L
R
CH5
LINE
POWER INPUT:
110-240V~50/60Hz
110-120V~60Hz - FUSE: T12A 250V
220-240V~50/60Hz - FUSE: T6.3A 250V
SERIAL NUMBER
www.cleveracoustics.co.uk
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN. NO USER
SERVICABLE PARTS INSIDE
MONITOR
LINE OUTPUT
G +
MONITOR
1W 8Ω
PRIORITY
– +
TEL PAGING
COM GNDHOT
110-120V~ 220-240V~
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
TEL
VOLUMEZONE
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 1 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 2 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 3 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 4 G – +
POWER CONSUMPTION (max.): 550W
2524 28 29
19 20 21 22 23 26 27
16 17 18 26 27
MA 4120 MKII Mixer Amplier
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 1
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 2
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 3
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 4
0
1
2
3
456
7
8
9
10
-10 +10
-10 +10
-10 +10
Z1
VOL
BASS
MUTE
TREBLE
GAIN
Z3
Z2
Z4
CH 5
-10 +10
-10 +10
-10 +10
010
PHONE
PHONE
VOLUME
MONITOR
VOLUME
010
VOLUME
ZONE 3
MONITOR
0
1
2
3
456
7
8
9
10
ZONE 1 ZONE 2
ZONE 4
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
VOLUME
MONITOR
0
1
2
3
456
7
8
9
10
ON
OFF
POWER
0
1
2
3
456
7
8
9
10
CH4 CH2
CH1CH3
L
R
CH5
LINE
POWER INPUT:
110-240V~50/60Hz
110-120V~60Hz - FUSE: T12A 250V
220-240V~50/60Hz - FUSE: T6.3A 250V
SERIAL NUMBER
www.cleveracoustics.co.uk
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN. NO USER
SERVICABLE PARTS INSIDE
MONITOR
LINE OUTPUT
G +
MONITOR
1W 8Ω
PRIORITY
– +
TEL PAGING
COM GNDHOT
110-120V~ 220-240V~
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
PHANTOM
LINE MIC
TEL
VOLUMEZONE
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 1 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 2 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 3 G – +
LINE OUT - BAL/UNBAL POWER AMP OUTPUT
COM 4Ω 8Ω 25V 70V 100VZONE 4 G – +
POWER CONSUMPTION (max.): 550W
71 2 3 6 911 13 15
810 10 12 144 5

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
5
Layout identication:
1. Gain control:
Thegaincontrolisusedtoadjusttheinputgain(level)foreachofthezonemixersinputchannels.Turn
thelevelcontrolanticlockwisetothelowestsetting,orturnclockwisetoadjusttothehighestsetting.
Adjustmentsshouldbemadegraduallytoavoidanysuddenchangestotheaudiooutput.Iftheaudio
sourceappearstosounddistorted,areductioningainmayberequired.
2. HF level control:
Duringinitialsetupthehighfrequencytoneadjustmentshouldbesettothezeropoint(12’o’clock
position).Turnthelevelcontrolanticlockwisetoreducethehighfrequencytones,orturnclockwise
toadjusttheincreasethehighfrequencytones.Adjustmentsshouldbemadegraduallytoavoidany
suddenchangestotheaudiooutput.
3. LF level control:
Duringinitialsetupthelowfrequencytoneadjustmentshouldbesettothezeropoint(12’o’clock
position).Turnthelevelcontrolanticlockwisetoreducethelowfrequencytones,orturnclockwise
toadjusttheincreasethehighfrequencytones.Adjustmentsshouldbemadegraduallytoavoidany
suddenchangestotheaudiooutput.
4. Mute switch:
Pressthemuteswitchtomute(silence)theselectedinputchannel.
5. Mute LED:
ThemuteLEDprovidesavisualindicationwhentheinputchannelisinmutestatus.
6. Input channel level control:
Thegaincontrolisusedtoadjusttheinputgain(level)foreachofthezonemixersinputchannels.Turn
thelevelcontrolanticlockwisetothelowestsetting,orturnclockwisetoadjusttothehighestsetting.
Adjustmentsshouldbemadegraduallytoavoidanysuddenchangestotheaudiooutput.Iftheaudio
sourceappearstosounddistorted,areductioningainmayberequired.Theinputchannellevelcontrol
adjuststheleveloftheselectedinputchannelwithinthemainmix.
7. Zone selection switches:
Eachoftheveinputchannelsmayberoutedtoanyofthefouroutputzones.
PresstheswitchtotheINpositiontoroutetheselectedinputchanneltothechosenoutputzone.
8. Headphone level control:
Theheadphoneoutputvolumeisadjustable.Turnthelevelcontrolanticlockwisetothelowestsetting,
orturnclockwisetoadjusttothehighestsetting.
9. Headphone output:
Utilisingastandard3.5mmstereojacksocket,theheadphoneoutputisusedalongsidethemonitor
functiontochecktheoutputofindividualoutputzones.Ifnoneoftheoutputzonesareselectedusing
themonitorselectionswitches,theheadphoneoutputwillbemuted.
Operating instructions

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
6
Operating instructions
10. LED VU output meter:
Theoutputtoeachzonemaybemonitoredvisuallyontheamplier.TheVUmeterhasthreegreen
stages,followedbyamberandthenred.Careshouldbetakentoavoidthesignallevelreachingthe
amberorredzonesasthiswillindicateaclippedsignalwithinthezonemixer.Inthisinstance,theInput
Channeland/orZoneOutputLevelshouldbereduced.
11. Monitor level control:
Themonitoroutputvolumeisadjustable.Turnthelevelcontrolanticlockwisetothelowestsetting,
orturnclockwisetoadjusttothehighestsetting.Thisisusedtocontrolthevolumeforthe1W8Ω
loudspeakeroutputontherearpanelofthezonemixer.
12. Zone output level control:
Themastervolumecontrolaffectsallaudiosourceswithintheamplier,routedtotheselectedzone.
Turnthelevelcontrolanticlockwisetothelowestsetting,orturnclockwisetoadjusttheoveralloutput
tothehighestsetting.Adjustmentsshouldbemadegraduallytoavoidanysuddenchangestotheaudio
output.
13. Monitor output selector:
Torouteoneoftheoutputzonestothemonitor&headphoneoutputs,presstheMonitorselection
button.ThemonitoroutputvolumecanthenbeadjustedusingtheMonitorVolumeControl.
14. Power LED:
ThePowerLEDwillilluminatetoindicatethezonemixerispoweredon.IfthepowerLEDisnot
illuminated,checkrstthepositionoftheon/offswitchandthencheckthemains(includingfuse)orDC
powersupply.
15. Power switch:
On/Offcontrolforthezoneamplier.Note:Theon/offpowerswitchdoesnothaveanycontroloverthe
24VDCpowerinput.
16. Cooling fan:
TheMA4120MKIIisfancooled.Thecoolingfanwillstartwhentheinternaltemperaturesensor
reaches50°C.Thefanspeedwillvaryaccordingtotheinternaltemperatureoftheamplier.Donot
blockorobstructthefanportontherearpanelortheairventsonthetoporsidepanels.
17. AC mains power input:
Beforeconnectingtheampliertothelocalmainsvoltageoutletshouldbecheckedtoensurethe
availablesupplyis240V~AC50Hz.ThisproductisCLASS1andrequiresaprotectivemainsearthtobe
connectedatalltimes.DONOTremoveordisconnecttheearth.
18. AC mains fuse:
Disconnectfromthemainspowersupplybeforeattemptingtoreplacethemainsfuse.Replacement
mainsfusesmustbethesameratingastheoriginal.T6.3AL250Vfor220-240VACmainssupplyor
T12AL250Vfor110-120VACmainssupply.

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
7
Operating instructions
19. AC voltage selector:
TheMA4120MKIIzonemixerfeaturesadualvoltagemainsinput.Disconnecttheunitfromthemains
voltagepowersupplybeforeattemptingtochangethemainsinputvoltage.Careshouldbetakento
selecttheappropriatemainsinputvoltagetomatchthatofthemainssupplyvoltage.
20. Monitor (MIX) line output:
Themonitorlineoutputcanbeusedtofeedexternalamplicationorrecordingequipment.TheMonitor
lineoutputprovidesanunbalanced(4V)signalfollowingthefrontpanel“monitor”selection.Ifseveral
zonesareselected,theoutputwillbeamixedsignalofalltheselectedzones.
21. Monitor loudspeaker output (1W 8Ω):
Auxiliaryconnectionfortheconnectionofasmallexternalloudspeakerforlocalmonitoringpurposes.
Thenominaloutputis1Wwithaminimumimpedanceof8Ω.Ifnoneoftheoutputzonesareselected
usingthemonitorselectionswitches,theheadphoneoutputwillbemuted.
22. Priority control terminals (Music Mute):
Whentheterminalsareshort-circuitedbymeansofaswitchorrelay(ierealarmpanel),input
channelsCH4andCH5willbemuted,leavinginputchannelsCH1,CH2andCH3withprioritystatus.
Note:TheTELinputcarrieshighestpriorityandwilloverridethePriority(MusicMute)function.
23. Telephone/paging input (TEL):
Foremergencypaging,theMA4120MKIIisequippedwithabalancedaudioTELinput,activated
automaticallyupontheMA4120MKIIdetectinganaudiosignalpresentontheTELinputterminals.
Theinputcarriesthehighestpriorityandwilloverrideallotherinputs&priorityfunctionson
theamplier.
24. Telephone/paging input zone selection & volume control:
TheTELinputfeatureszonecontrolandinputvolumecontrol.ToroutetheTELsignaltoadesired
outputzone,movethecorrespondingDIPswitchtothedown(ON)position.Theinputvolumeforthe
TELsignalmaybecontrolledbytherecessedvolumecontrolpotentiometer.Formostapplications,it
maybebestpracticetosettheminimumpossibleleveltopreventunwantedactivationofthepriority
input.Turnthepotentiometerclockwisetoincreasethevolume.
25. Stereo LINE inputs:
AstereoaudioinputisprovidedforsourcessuchasFMTuners,CDPlayersorMP3Players.Theinput
featuresapairofunbalancedphono(RCA)inputssuitableforlinelevelaudioinput.
26. Mono MIC/LINE inputs:
Channels1,2,3&4allfeaturemonoaudioinputs,eachwithselectorforusewithMIC/MIC+Phantom/
Linesignals.TheaudioinputisdesignedtoacceptabalancedaudiosignalviaXLRor6.35mm(¼”)
TRSjack.
Channel1featuresautomaticpriorityoverrideoverchannels2,3and4.Ifthisfeatureisnotrequired,
theusermustrefertoaservicetechnicianwhowillbeabletofollowtheinstructionsonpage9to
defeatthevoicepriorityfunction.

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
8
Operating instructions
27. Input sensitivity and phantom power control:
Channels1,2,3&4eachfeatureswitchableinputsforusewithMIC/MIC+Phantom/Linesignals.The
MICposititionisdesignedtoacceptabalanced,lowlevelsignalfromastandarddynamicmicrophone
(5mV/1kΩ).ThePHANTOMpositionisdesignedtoprovide15VphantompoweracrossXLRpins2&3
forusewithcondensermicrophones.TheLINEpositionisforusewithlinelevelsourcessuchasradio
microphonereceivers,CDplayersandFMtuners(100mV/10kΩ),thesignalmaybeinputtedusing
eitherthebalancedXLRorbalancedTRS6.35mm(¼”)jack.
28. Balanced line level zone outputs:
TheMA4120MKIIfeaturesfour,independentzoneoutputseachutilisingbarrierstripterminalsforthe
balancedaudiooutput(1.7V).Thelineleveloutputsmaybeusedtofeedsignaltoexternalamplication
whereadditionalamplicationisrequired.Iftheamplierconnectedonlyrequiresanunbalancedsignal,
theoutputcontacts“+”and“G”shouldbeused.
29. Power amplier outputs:
EachofthefouroutputzonesontheMA4120MKIIfeaturesbothlowimpedanceandconstantvoltage
loudspeakeroutputs.Eachoutputzonemaybeusedtooutputintoeitherlowimpedance(4-8Ω)or
constantvoltage(25V,70V,100V).Donotusemorethanonepairofoutputterminalsonanyone
outputzone.Careshouldbetakenwhenconnectingtotheoutputstoensuretheloadimpedanceis
abovetheminimumloadspeciedfortheoutput.
Power on/off procedure:
Priortomakinganyconnectiontothemainspoweroraudioinputs/outputs,turnalllevelcontrols
counterclockwisetothe“0”positionandalltone(equaliser)controlstothemid(zero)point.Deselect
allmonitorandzoneselectioncontrols.
Switchonthezonemixerandanyaudiosources(MP3players,CDplayers,Microphonesetc)before
poweringthesystemsamplierON.Thelastproducttobeswitchedonshouldbethepower/slave
amplierstopreventanyunwantednoiseorpotentialdamagetospeakersorampliers.Ifyouwish
topoweroffthesystem,turntheamplier’smastervolumecontrolcounterclockwisetothe“0”
positionbeforeswitchingtheamplierOFFbeforeanyaudiosourcesareswitchedoff.Byfollowingthis
procedureitwillpreventacousticshockstothespeakersorpotentialdamagetosystemcomponents.
Afterconnectingallaudiosourcesandpoweringonthesystem,adjustthelevelofeachaudioinput,
selectthezoneroutinginordertoachievethedesired“mix”foreachzone.Careshouldbetaken
towhenadjustingmicrophoneinputvolumesandthemastervolume,adjustbothoftheseinsmall
increment’stoavoidfeedback(howlaround).Thegoalistoachieveaclearbalancebetweenmusicand
voiceensuringannouncementscanbeclearlyheard.

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
9
Operating instructions
MIC priority:
DuringnormaloperationtheMA4120MKIIfeaturespriorityforMIC1overtheothermicrophoneand
lineinputs.Forcertainapplications,theinstallationengineermayneedtodefeattheMIC1priority
function.Inordertodothis,theproductmustbefullydisconnectedfromanyACorDCpowersources,
anddisconnectedfromallinputs/outputs.
Removethe15screwsfromtheoutercasingasperthediagrambelowandkeepinasafelocation.
Removetheuppercasingandplacetooneside.LocatethePCBtowardstherearoftheunitaspictured
below.Carefullymovethejumperfromthe"ON"positiontothe"OFF"position.Rettheoutercasing,
takingcaretoavoiddamagingtheunit.Retallofthescrewstofullysecuretheoutercasing.
TopofMixer
RearofMixer
Side1of
Mixer
Side2of
Mixer

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
10
Typical panel connections
Mains
Recorder
PAAmplier
Recorder
CDPlayer
AM/FMTuner
DesktopMic
Microphone
Monitor
Speaker
Amplier
Contact
“VoicePriority”
Horn
speaker
Column
speaker
Speaker

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
11
Rack installation:
TheMAseriesisrackmountable.Therackyouuseshouldbeadoubledoorrackwhereyoucanopen
thefrontandrearpanel.Whenmountingtheamplierintotherack,pleasemakesurethatthereis
enoughspacearoundtheamplier.
Becarefulwhenmountingtheamplierintotherack.Puttheheaviestproductsintothelowerpartof
therack.
Thefrontpanelisnotdesignedtoabsorbaccelerationforcesoccurringduringtransportation.
Inputs:
Shortcablesrunsimprovethesoundqualityremarkably.Inputcablesshouldbeshortanddirect,since
highfrequencieswillmostlybeabsorbedifthecablesareunnecessarilylong.Besidesthatalonger
cablemayleadtohummingandnoiseproblems.Ifthecablerunsareunavoidable,youshoulduse
balancedcables.
Outputs:
Thehighdampingfactorofyourampliersuppliesaclearsoundreproduction.Unnecessarilylongand
thincablesusedforlowimpedance(4-16Ω)speakerswillinuencethedampingfactorandthusthelow
frequenciesinanegativeway.Inordertosafeguardgoodsoundquality,thedampingfactorshouldlie
around50.Thelongeracablehastobethethickeritshouldbe.Forlongercablerunspleaseensure
the100Voutputsareusedfor100Vspeakers.
Connectyourspeakersystemsviathespeakerterminals(COM=-VE)
Examples: 1)COM+4-16Ω
2)COM+70V
3)COM+100V
Note:Pleasedonotusemorethanonepairofoutputterminalsonanyoneoutputzone.
Installation

www.cleveracoustics.co.uk MA 4120 480W Mixer Amplier User Manual
12
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
This manual suits for next models
1
Table of contents
Other Clever Acoustics Amplifier manuals

Clever Acoustics
Clever Acoustics MA 130 100V 30W User manual

Clever Acoustics
Clever Acoustics SL 120 100V User manual

Clever Acoustics
Clever Acoustics MA 120 User manual

Clever Acoustics
Clever Acoustics MA 2120 User manual

Clever Acoustics
Clever Acoustics MA 4040 User manual

Clever Acoustics
Clever Acoustics CRAM39 User manual

Clever Acoustics
Clever Acoustics MA 135 User manual

Clever Acoustics
Clever Acoustics MA 4060MP User manual

Clever Acoustics
Clever Acoustics CRAM19A User manual

Clever Acoustics
Clever Acoustics CPA 40 User manual