© Climecon 1
Installation guide ECO1
Parts of the air-forced heater ECO1
1. Rear part, collar, heating element, electronic part and contacts for
supply voltage (230V) and for the thermostat cabling
2. Perforated cover
3. Fixing screw for the perforated cover (2 pcs)
4. Fixing screw for the rear part (to a wall, 4 pcs)
Installation of the air-forced heater ECO1
1. Drill holes into the wall for wires and fixing screws (4), using the
cutout template supplied with the delivery (for the cutout template
see Appendix 1).
2. The minimum distance of the supply-air unit from the ceiling is
10 mm (see Figure 1.1). The minimum installation height from the
floor is 1,8 m. The diuser must be installed in a place where children
can’t touch it without supervision.
3. Remove the two fixing screws (3) of the perforated cover (2) and pull
the cover away from the rear part (1).
4. Push the collar of the rear part inside the supply air duct and fix the
rear part to the wall, using four screws (4), Ø max 5 mm.
5. Connect the supply cable of the supply air unit (MMJ) and the control
cable of the thermostat (KLMA) to the terminals of the electronic
part of the supply air unit as shown on Figure 2.
6. Check that all the connections are correct. Push the perforated cover
back onto the rear part and fix it properly using the fixing screws of
the cover.
7. Mark the power switch and temperature drop function switch clearly.
Connection
1. Connect supply voltage (230V) to terminals N and L of the electronic
part of the supply air unit as shown on Figure 2.
2. Connect the grounding to the separate ground terminal in the supply
air unit as shown on Figure 2.
3. Connect the supply air unit of the ECO series to the thermostat by
means of the KLMA cable as shown on Figure 2.
4. You can activate temperature drop function by connecting terminals
Z1 and G0 in the thermostat as shown on figure 5.
5. When two or more forced-air heaters are controlled with one regulat-
ing unit, the G pole of the power unit in only one supply air unit is
connected. The poles G0 and A2 are again connected from all con-
trolled power units. The supply air devices must be connected in the
same phase in the distribution box.
Note! Connection may be performed only by
a person with necessary professional skills.
WARNING! 230V voltage inside the unit.
U = 230V
In= 2,4 A
IA= 3,7 A
3
2
4 1
NNLL
L
N
GO
G A2
Z1 G A2
G0 A1
24 VAC
230 VAC
ECO
Thermostat
ECO
Air-forced Heater
ECO1 distance from the ceiling
Min. 10 mm
Cabling modes of the ECO heating system
An all-pole switch must be used on the connection cable. All-pole switch with at least 3mm contact opening shall be used.
Figure 1
Figure 1.2
Figure 2
Figure 3
12.13
ECOT REGULATOR
Z1G0 G A1 A2
ECO Supply Air Unit
G G0 A2
KLMA
3x0.8+0.8
L N
MMJ
3xX,XS
USE TYPE C CIRCUIT BREAKERS
ECOT REGULATOR
Z1G0 G A1 A2
ECO Supply Air Unit
G G0 A2
KLMA
3x0.8+0.8
L N
MMJ
3xX,XS
ECO Supply Air Unit
G G0 A2
L N
MMJ
3xX,XS
KLMA
2x0.8
ECOT REGULATOR
Z1G0 G A1 A2
ECO Supply Air Unit
G G0 A2
KLMA
3x0.8+0.8
L N
MMJ
3xX,XS
ECO Supply Air Unit
G G0 A2
L N
MMJ
3xX,XS
KLMA
2x0.8
ECO Supply Air Unit
G G0 A2
L N
MMJ
3xX,XS
KLMA
2x0.8
Figure 3
climecon.fi
© Climecon 2
Installation guide ECOT, thermostat
Commissioning
1. Make sure that the connections are made correctly.
Turn on the 230V supply voltage coming to the supply air
unit. The display (7) will show the room temperature and
the LED (6) will light up. The factory setting of the ther-
mostat is 21ºC (central point of the setting area) and if
the room temperature is lower, the led will turn red and
the heating will be switched on, otherwise a green led will
be illuminated.
2. When the value of the thermostat is changed (± 3ºC from
the value of the central point) with the control knob (4),
you can see the new setting value on the display (7).
3. Changing the central point of the setting area to e.g. 24ºC.
Open the cover (2) of the thermostat and turn the tem-
perature control knob (4) up (extreme position). Remove
jumper S3 and install it back to its position. The new
central point of the setting area will now be 24ºC.
4. The factory set accuracy of temperature adjustment is
± 0.5ºC. If you need to change the accuracy to ± 1ºC,
remove jumper S2.
5. Temperature drop from the setting value of 3ºC...10ºC
is adjusted from the knob (8). The value of temperature
drop is visible on the display (7).
6. After you have made all the necessary changes, reinstall
the cover (2) and the system is ready for use.
Installation of the thermostat:
1. Bring the cable intended for the thermostat unit (KLMA)
from the supply air unit either to the instrument box
(60 mm spacing between holes) or directly to a surface-
mounted ECO thermostat.
2. Remove the cover (2) of the thermostat from the rear part
(1), using e.g. a small screwdriver (clips at the upper and
lower edge of the thermostat).
3. Fix the rear part of the thermostat either to the instrument
box or directly on the wall, using screws (3).
4. Connect the cables to the terminal block (5) as shown on
Figure 2.
5. If the temperature drop function is taken into use, connect
it as shown on Figure 5.
6. After all the connection work, check the connections and
reinstall the cover of the thermostat.
Parts of ECO thermostat
1. Rear part
2. Cover
3. Fixing screw (to a wall, 2 pcs)
4. Temperature control knob
5. Terminal block
6. Signal LED
7. Temperature display
8. Control knob for changing the setting
value of temperature drop
9. Jumpers S2 and S3
2
1
4
3
5
6
7
8
9
Z1
GO (0V)
CLOSED = DROP
OPEN= NO DROP NPN CONDUCTS= DROP
NPN DOES NOT
CONDUCT= NO DROP
0V = DROP
10V = NO DROP
ECO-thermostat ECO-thermostat ECO-thermostat
Z1
GO (0V)
Z1
GO (0V)
+
0/10V
-
Figure 4
Figure 5
Figure 6
1.
2.
Temperature drop alternatives of ECO thermostat
climecon.fi
© Climecon 3
Installation instructions ECO1
2x
1
3
5
2
4
Note! Connection work may be performed only by a person with necessary professional skills.
climecon.fi
© Climecon 4
Service instruction ECO1
1
3
5
2
4
6
Note! Connection work may be performed only by a person with necessary professional skills.
Warning! 230V voltage inside. Turn o the supply voltage before maintenance.
Note! Check also the condition of the supply air filter of the air handling unit.
1
02x

Other Climecon Heater manuals

Climecon ECO4 User manual

Climecon

Climecon ECO4 User manual

Climecon ECO-C User manual

Climecon

Climecon ECO-C User manual

Climecon Climecon ECO4 User manual

Climecon

Climecon Climecon ECO4 User manual

Climecon ECO2 User manual

Climecon

Climecon ECO2 User manual

Climecon ECO-W User manual

Climecon

Climecon ECO-W User manual

Popular Heater manuals by other brands

IRSAP Dedalo manual

IRSAP

IRSAP Dedalo manual

Master DC 61 User and Maintenance Book

Master

Master DC 61 User and Maintenance Book

JOCCA 1590 instruction manual

JOCCA

JOCCA 1590 instruction manual

Klarstein BORNHOLM CURVED SMART manual

Klarstein

Klarstein BORNHOLM CURVED SMART manual

S&P 3MCN User instructions

S&P

S&P 3MCN User instructions

Kohler Veil S600P Installation and Homeowners Guide

Kohler

Kohler Veil S600P Installation and Homeowners Guide

Lotus RI - 4 EM Instructions for installation and use

Lotus

Lotus RI - 4 EM Instructions for installation and use

Elcon BH-1500 manual

Elcon

Elcon BH-1500 manual

Sawo Altostratus Series manual

Sawo

Sawo Altostratus Series manual

Dyna-Glo BF10PTDG-4 manual

Dyna-Glo

Dyna-Glo BF10PTDG-4 manual

Kerbl SunnyBoy 22258 Instructions for use

Kerbl

Kerbl SunnyBoy 22258 Instructions for use

Toyotomi KS-47B Operation and maintenance instructions

Toyotomi

Toyotomi KS-47B Operation and maintenance instructions

VEAB Heat Tech ROBUST-F Installation and user instructions

VEAB Heat Tech

VEAB Heat Tech ROBUST-F Installation and user instructions

Dimplex BS 120 Instructions for use

Dimplex

Dimplex BS 120 Instructions for use

PRODUX PRO 29848 manual

PRODUX PRO

PRODUX PRO 29848 manual

Econo Heat OMNI OWH-500 Installation, operation and service instructions

Econo Heat

Econo Heat OMNI OWH-500 Installation, operation and service instructions

Fondital Alcor FA Installation and maintenance manual

Fondital

Fondital Alcor FA Installation and maintenance manual

EQUATION DL01C-1 EQ Assembly, Use, Maintenance Manual

EQUATION

EQUATION DL01C-1 EQ Assembly, Use, Maintenance Manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.