www.cls-led.com www.cls-led.com
- 9 - - 10 -
“hYb” = Hybrid
“aNa” = Analog (onstant urrent Reduction)
“DiG” = Digital (Stochastic Signal ensity Modulation)
Control resolution 8 Bit.
1 DMX channel per output.
0% 100%
SSDM
0% 100%
Hybrid 0% 5% 100%
CCR
To adjust the Patch Value of an output channel
enter the corresponding page and change the
value. The Patch value can be adjusted from 0
– 4. To return to the main menu press the menu
button.
-Page X: X
Use Up/Down
button
Press the Menu button
to return
Page 7:
Press the Menu button
to enter or return
Page 6:
Use Up/Down
button
Press the Menu button
to return
To adjust the Static Value of an output channel
enter the corresponding page and change the
value. The Static value can be adjusted from 0 –
255. To return to the main menu press the menu
button.
-Page X: X
Use Up/Down
button
Press the Menu button
to return
To adjust the current of an output channel enter
the corresponding page and change the value. The
current can be adjusted from 350 – 1000mA in
steps of 50mA. To return to the main menu press
the menu button.
-
Page X: X
Use Up/Down
button
Press the Menu button
to return
..
Entering this page will result in a test loop on the
outputs of the LDC-41. This enables the user to
test the connections without the need of an DMX
controller. To end the test sequence and return to
the main menu press the menu button.
"YES" = Will copy the DMX values
"No" = Return without recording
Current firmware version on the LDC-41.
Test sequencePage 22:
Press the Menu button
to enter or return
X
Page 21:
Press the Menu button
to enter or return
-
Page 20:
Use Up/Down
button
Press the Menu button
to return
After all changes are made the setting need to be
stored before they become active. To store the
settings go to the store page and press and hold
the menu button for 3 seconds. The settings are
stored and you will return to the status display.
Status display
Page 23:
Hold the Menu button
for 3 seconds to store
When you have made changes but you don’t want
to store them you can cancel the settings. Go to
the cancel page and press and hold the menu
button for 3 seconds. The settings are not stored
and you will return to the status display.
Status displayPage 24:
Hold the Menu button
for 3 seconds to cancel