11
ENGLISH
Information requirment for electric local space heaters
Model identifier(s): SPH01-04TP / Art.No: 36-7861
Item Symbol Value Unit Item
Heat output Type of heat input, for electric storage
local space heaters only (select one)
Nominal heat output Pnom 0.4 kW manual heat charge control, with
integrated thermostat No
Minimum heat output
(indicative) Pmin 0.4 kW
manual heat charge control with
room and/or outdoor temperature
feedback
No
Maximum continuous
heat output Pmax, c 0.4 kW
electronic heat charge control with
room and/or outdoor temperature
feedback
No
Auxiliary electricity
consumption --- --- --- fan assisted heat output No
At nominal heat
output elmax N/A kW Type of heat output/room temperature
control (select one)
At minimum heat
output elmin N/A kW single stage heat output and no
room temperature control No
In standby mode elSB 0.00034 kW Two or more manual stages, no
room temperature control No
with mechanic thermostat room
temperature control No
with electronic room temperature
control No
electronic room temperature control
plus day timer No
electronic room temperature control
plus week timer Yes
Other control options (multiple
selections possible)
room temperature control, with
presence detection No
room temperature control, with open
window detection Yes
with distance control option No
with adaptive start control No
with working time limitation Yes
with black bulb sensor No
Contact details CLAS OHLSON AB, SE-793 85 INSJÖN, SWEDEN
Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode Ecodesign requirements, from 7 January 2013 Result - Remark Verdict
Off mode Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
0 P
Standby mode Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any
condition providing only a reactivation function,
or providing only a reactivation function and a
mere indication of enabled reactivation function,
shall not exceed 0.50 W.
/ N/A
The power consumption of equipment in any
condition providing only information or status
display, or providing only a combination of reacti-
vation function and information or status display
shall not exceed 1.00 W.
0.34 P
Seasonal space heating energy efficiency
Description Value
Seasonal space heating energy efficiency in active mode-ηS,on 40 %
F(1) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and a negative contribution
to seasonal space heating efficiency for commercial local space heaters due to
adjusted contributions for options for the heat output, expressed in %;
0 %
F(2) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, the values of which are mutually exclusive, cannot be added to
each other, expressed in %;
7 %
F(3) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort the values of which can be added to each other, expressed in %;
1 %
F(4) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %; 0 %
F(5) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by energy consumption of a permanent pilot flame,
expressed in %.
0 %
Seasonal space heating energy efficiency-ηS38 %
Verdict P