Comm Box ZTP0015 User manual

CommBox ZTP0015
Room Movement Sensor (RMS)
Instruction Manual
COMMBOX Pty Ltd abn: 431 583 817 05 Telephone +61 2 9938 4811 Fax: +61 2 9905 6153
PO Box W105, Warringah Mall, NSW 2100, Australia w w w . c o m m b o x . c o m . a u
AUSTRALIA, CHINA, MALAYSIA, SINGAPORE, KOREA, SOUTH AFRICA
To the InstallerR
Thank ou for choosing CommBox Room
Movement Sensor (RMS)
The RMS uses passive infra-red technolog
to detect movement in a room. It is
intended to be used with the CommBox
range of control s stems to automaticall
shut down equipment in the room after a
period of time when no movement is
detected, so saving energ and
maximising projector lamp life.
Before commencing installation, please
read these instructions carefull to get the
best results from our RMS.
For your safety
Please ensure that an wiring used to
connect RMS to other equipment is kept
clear of mains wiring and follows
applicable local wiring codes. Under no
circumstances ma an RMS be connected
directl to power mains wiring.
Make sure that the power suppl ou are
using meets our local safet regulations
and that its voltage does not exceed 15
volts DC. Unregulated power supplies can
output voltages that are well above what is
shown on their label.
The RMS is intended for indoor use onl .
Mounting
Choose a location on a wall that is
preferabl 3 to 4 metres from the floor, not
adjacent to heating or air conditioning
outlets or opposite windows and where
people moving in the room can be “seen”
b the RMS.
Remove the cover b placing a small flat-
bladed screwdriver in the bottom of the
case and gentl prise the cover off.
D N T T UCH THE PYR SENS R
INSIDE WITH Y UR FINGERS!
You ma remove the circuit board to
facilitate mounting the base to the wall. To
do this, lift the white plastic tab at the
lower side and push the board up until it
clears the ke hole slot at the top. At this
point the board ma be lifted out of the
base.
When replacing the board, to achieve
optimum coverage, adjust the position of
the board in the base to match the height
of the RMS above the floor. Moving the
board higher will lower the beam angle.
Please refer to the Mounting Height scale
on the right-hand side of the board.
After wiring, refit the cover with its lens.
The cover must be in place in order to test
the RMS.
This product
conforms to the
EMC directive
89/336 CCE
Ke hole
slot
Cable
access
knockout
Mounting
height
pointer
Mounting
hole
knockout
P ro
sensor
White plastic
tab
Wiring
Connect the terminals as shown in the
diagram to the control panel or access
port.
You do not need to connect the tamper
switch terminals.
Option links
Tamper switch
Alarm + -
N/C 12v
Blue-Wh GND
Orange +12v
Blue Sensor
PCB0241C
DC In
PIR RS232 Port 2 RS232 Port 1
IR Otput 1 IR Output 2
Progm Port IRBus
+12V GND
Data
RS232 Port
Pin 4 - TxD
Pin 5 - GND
Pin 6 - CTS
PIR Port
Pin 5 - GND
Pin 4 - Sense
Pin 6 - +12V
Command
S stems P/L
Joe Panel
SK9
SK8
SK7 SK6 SK5 SK1
SK2SK4 SK3
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
Joey
ption Links
For the purpose of detecting room
occupanc , we are not as concerned
about false alarms as we would be if
this were a securit s stem. In fact,
not detecting room movement (when
people are in the room) would be more
of a problem.
For this reason, Long Range and
Short Pulse Count links should be
fitted. Similarl , having the LED
activate is a benefit.
So for our application, fit all 3 links.
Testing
With the cover fitted, appl power and
wait at least 30 seconds. After this time, if
there is no movement, the LED should go
out. Once this has happened, an
movement should cause a couple of rapid
flickers and the LED should lock on for
about 5 seconds.
Walk around the room and check that our
movement can be reliabl detected. If
range seems to be inadequate, check the
position of the PCB in the base. A higher
position lowers the angle of the detection
beam.
Programming your control panel
to recognise the RMS and perform
actions
In CommBox Control S stem editor, select
Device ptions under the Handset menu.
The Inactivity Timeout option allows ou to
choose the number of minutes after either
the last ke is pressed or the RMS sensor
detects movement. When that time expires
with no movement detected or ke pressed,
the actions ou choose under Edit Actions will
occur.
After ou have selected the time, click Edit
Actions. You can treat this just like the
programming of an other ke .
For more information
Please refer to the control panel’s manual for
more information.
www.commands stems.com.au
For Support please call:
+61 02 9938 4811

Popular Security Sensor manuals by other brands

Tatsuta Electric Wire & Cable AD-AS-1C-SR Operation manual

Tatsuta Electric Wire & Cable

Tatsuta Electric Wire & Cable AD-AS-1C-SR Operation manual

Fike FIK-2351 Installation and maintenance instructions

Fike

Fike FIK-2351 Installation and maintenance instructions

B.E.G. KNX RC-plus next 230 KNX Operating and mounting instructions

B.E.G.

B.E.G. KNX RC-plus next 230 KNX Operating and mounting instructions

Leedarson Multi-Sensor quick start guide

Leedarson

Leedarson Multi-Sensor quick start guide

ESYLUX PROTECTOR WD 9 V manual

ESYLUX

ESYLUX PROTECTOR WD 9 V manual

BEA WIZARD SMR user guide

BEA

BEA WIZARD SMR user guide

Pyronix KX15DC-WE manual

Pyronix

Pyronix KX15DC-WE manual

MTI Industries Safe-T-Alert SA-10XL user manual

MTI Industries

MTI Industries Safe-T-Alert SA-10XL user manual

GL Sciences LD239 user guide

GL Sciences

GL Sciences LD239 user guide

Isolite RWL-C EXIT installation instructions

Isolite

Isolite RWL-C EXIT installation instructions

Browan MerryIoT Sensors Quick installation guide

Browan

Browan MerryIoT Sensors Quick installation guide

Inficon TEK-Mate operating manual

Inficon

Inficon TEK-Mate operating manual

Bluetech LD Series operating instructions

Bluetech

Bluetech LD Series operating instructions

Watts H2iQ Series Installation and operation manual

Watts

Watts H2iQ Series Installation and operation manual

SECURITY SENSOR ZEBRA-24.60 user manual

SECURITY SENSOR

SECURITY SENSOR ZEBRA-24.60 user manual

TEUFELBERGER OP 8MM E2E P Manufacturer's information and instructions for use

TEUFELBERGER

TEUFELBERGER OP 8MM E2E P Manufacturer's information and instructions for use

RTI Scatter Probe manual

RTI

RTI Scatter Probe manual

Di-soric LA Series operating instructions

Di-soric

Di-soric LA Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.