manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pyronix
  6. •
  7. Security Sensor
  8. •
  9. Pyronix KX15DC-WE User manual

Pyronix KX15DC-WE User manual

Other Pyronix Security Sensor manuals

Pyronix KX10DTP User manual

Pyronix

Pyronix KX10DTP User manual

Pyronix KX18DC User manual

Pyronix

Pyronix KX18DC User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix XDH10TT-WE User manual

Pyronix

Pyronix XDH10TT-WE User manual

Pyronix KX15DD User manual

Pyronix

Pyronix KX15DD User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix Kudos DT User manual

Pyronix

Pyronix Kudos DT User manual

Pyronix Kudos User manual

Pyronix

Pyronix Kudos User manual

Pyronix XDH10TTAM User manual

Pyronix

Pyronix XDH10TTAM User manual

Pyronix KX15DT1 User manual

Pyronix

Pyronix KX15DT1 User manual

Pyronix KX15DQ User manual

Pyronix

Pyronix KX15DQ User manual

Pyronix HIKVISION SMOKE-WE User manual

Pyronix

Pyronix HIKVISION SMOKE-WE User manual

Pyronix XDL15TT-AM User manual

Pyronix

Pyronix XDL15TT-AM User manual

Pyronix PCX 46 APP Owner's manual

Pyronix

Pyronix PCX 46 APP Owner's manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix KX10DP-WE User manual

Pyronix

Pyronix KX10DP-WE User manual

Pyronix EQUINOX 10/15 User manual

Pyronix

Pyronix EQUINOX 10/15 User manual

Pyronix KX15DT User manual

Pyronix

Pyronix KX15DT User manual

Pyronix XD10TTAM User manual

Pyronix

Pyronix XD10TTAM User manual

Pyronix BREAKGLASS 2000 User manual

Pyronix

Pyronix BREAKGLASS 2000 User manual

Pyronix KX15DQ User manual

Pyronix

Pyronix KX15DQ User manual

Pyronix FPKX15DT2 User manual

Pyronix

Pyronix FPKX15DT2 User manual

Pyronix KX15DTAM User manual

Pyronix

Pyronix KX15DTAM User manual

Pyronix HomeControl+ Installation and operating manual

Pyronix

Pyronix HomeControl+ Installation and operating manual

Popular Security Sensor manuals by other brands

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

Rielta Ladoga MK-RK installation guide

Rielta

Rielta Ladoga MK-RK installation guide

Mirion Technologies ACCURAD PRD user manual

Mirion Technologies

Mirion Technologies ACCURAD PRD user manual

Bosch DS835 installation instructions

Bosch

Bosch DS835 installation instructions

Lamptime ST05C instructions

Lamptime

Lamptime ST05C instructions

Ubiquiti MFI-MSC quick start guide

Ubiquiti

Ubiquiti MFI-MSC quick start guide

Subsite 910R Support

Subsite

Subsite 910R Support

Satel OPAL Pro manual

Satel

Satel OPAL Pro manual

Aleph XC-1XTEU manual

Aleph

Aleph XC-1XTEU manual

Pima LARIS QUAD installation instructions

Pima

Pima LARIS QUAD installation instructions

Solinst 301 user guide

Solinst

Solinst 301 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

RIN1586-2
KX15DC-WE 15m Internal detector
WHITE
3mmABS, 0.4mm HDPE in lens area
868MHz, FM Transceiver Narrow Band
Fully Encrypted Rolling Code
300m Free Space
Low Noise Pyroelectric Sensor
High, Low
Advanced Automatic
15m
24
0.3 - 3.0 m/s
20
CR123A Lithium Battery
Greater than 2 years
2.4m or 4m
Front and RearTamper
-20°C to 50°C
-10°C to 40°C
-10°C to 50°C
Wall and ceiling mounting brackets optional
EN55022 Class B / EN50130-4
Model:
Colour:
Casing:
Transmission Frequency:
Tranmission Method:
Transmission Range:
Detection Method:
Sensitivity:
Temperature Compensation:
Detection Range:
Detection Zones:
Detection Speed:
Detection Angle:
Battery:
Battery Life:
Mounting Height:
Tamper Switch:
Accessories:
Emissions / Immunity:
Pyronix Limited, Secure House, Braithwell Way,
Hellaby, Rotherham, S66 8QY. UK
Customer Support Line : +44(0)845 6434 999
or telephone +44(0)1709 535225
E-mail: customer[email protected]
website: www.pyronix.com
WARRANTY
This product is sold subject to our standard warranty
conditions and is warranted against defects in
workmanship for a period of two years
In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserves the
right to amend specifications, without giving prior
notice.
(batteries
excluded)
This product is approved for use in the Residential,
Commercial and Light Industrial Environment.
.
Coverage Pattern
®
EN50131-2-2:2008
EN50131-5-3:2005+A1:2008
Security Grade 2
Environmental Class II
Suitable for use in systems installed
to conform to PD6662:2010
2
®
KX15DC-WE Specifications
®
KX15DC-WE
15m Digital Curtain Wireless PIR
Storage Temperature:
Certified Operating Temp:
Nominal Working Temp:
2.5V +/- 5% at 25
°C
Low Battery Threshold:
O
20
24 zone edges
6 planes
2m 3m 4m 5m 6m 7m 8m 9m 11m 12m 13m 14m
1m 10m
2m 3m 4m 5m 6m 7m 8m 9m 11m 12m 13m 14m
1m 10m 15m
15m
15m
4m
2.4m
2m 3m 4m 5m 6m 7m 8m 9m 11m 12m 13m 14m
1m 10m
HORIZONTAL COVERAGE
VERTICAL COVERAGE
NOTE: Only the KX15DCHT-WE has
been certified by IMQ.
CASE LID
SCREW FITTING
NOTE: When mounting the
Part number: FPKXBRACKET
WallCeiling
detector, ensure that it is
not tilting backwards.
Installation Wall Mounting
The KX15DC-WE Printed Circuit Board
Learning the KX15DC-WE onto the Enforcer 32-WE Control Panel
Changing The Battery
Optional Bracket Fitting Dimensions Avoiding False Alarms
69mm
(2.72”)
3mm
(0.12")
50mm
(2.2”)
117mm
(4.61”)
Kg = 105g (3.4 oz) without bracket
RINS1586-2
Header On
= HIGH)
Header Off
= LOW
SENSITIVITY
DIGITAL SIGNAL
PROCESSING SELECT
Header On
LED ON
LED OFF
Header Off
ALARM LED
To prevent possible damage to components,
any static charge on your body needs to be
eliminated before touching the inside of the
unit. This can be accomplished by touching
some grounded/earthed metallic conductor
such as a radiator/pipework immediately
before replacing the batteries.
The batteries supplied have been chosen to
provide long service life whilst, for safety
reasons, having limited output current.
Replace only with approved batteries.
Tamper Spring
Alarm LED ON/OFF
Sensitivity Settings
Piro Sensor
DO NOT TOUCH
Learn Button
Battery Header for Rear Tamper
+
-
When you are ready to learn the device to the
control panel receiving equipment, and when the
equipment is in the learn mode follow the
procedure below:
1. Make sure the battery is installed correctly
and the plastic wrapping removed.
2. Press and Hold the Learn button until the
3 LEDs start cycling through the different
colours, then release the Learn button.
3. The device is correctly learnt when the
Green LED flashes.
The three coloured LEDs give a
visual indication of the signal
strength.
Green indicates good signal strength
and is a good location to install.
Red indicates poor signal
strength and the device should not
be installed in that position.
If no LED illuminates then the device
is completely out of range.
RED BLUE GREEN
The blue LED will illuminate when
the device is activated.
For electrical products sold
within the European
Community. At the end of the
electrical products life, it
should not be disposed of
with household waste. Please
recycle where facilities exist.
Check with your Local
Authority or retailer for
recycling advice in your
country.
RED BLUE GREEN
RED BLUE GREEN
RED BLUE GREEN
RED BLUE GREEN
mralA
CR123A
LITHIUM
BATTERY
+-
REAR TAMPER
NVM RESET
CR123A
LITHIUM
BATTERY
+-
1. Avoid placing the detector in direct sunlight.
2. Do not let pets and other animals wander
freely whilst the alarm system is armed.
3. Do not mount the detector near heaters or
radiators.
4. Do not mount the detector near open
windows or air vents.
5. Mount the detector on a stable surface.
6. Do not partially or completely obscure the
detectors field of vision with large objects.
When disposing of the
product, the battery must be
removed and disposed of
separately in accordance
with the local regulations
Please see the Enforcer 32-WE user, programming and quick set
up manuals for further information