manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Comnet
  6. •
  7. Transceiver
  8. •
  9. Comnet FDX50M2 User manual

Comnet FDX50M2 User manual

Mechanical Installation Instructions
Figure 1: Dimensions are for a ComNet™surface mount unit.
FDX50M2
Installation Considerations
This fiber-optic link is supplied as
aStandalone module. Units should be
installed in dry locations protected
from extremes of temperature and
humidity.
Standalone Module:
The unit is provided with a mounting
plate with a hole for two No. 6 pan
head screws (3-mm or 3.55-mm).
Attach the module to a solid piece
of wood using two No. 6 pan head
wood screws with a minimum
penetration intothe wood of
3/4 inch. (Screws not supplied)
See figure 1.
1. Determine where the module will be
installed, and ensure that there is
adequate space at both ends for
making the various cable
connections and for reading the
diagnostic LEDs.
2. Attach the module to a flat surface
using two mounting screws.
(Not Supplied)
INS_FDX50M2_REVA
01/20/09
Page 1
Power Sources - The product should only be operated from the recommended power source.
Use only a UL Class 2 indoor/dryor Class 3 outdoor/wet power supply.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should beinstalled in a restricted access location; available through the use
of a lock and key or other means of security. Access should be limited to service personnel who
have been instructed about the reasons for the restrictions to the location. Any and all
precautions should be taken and controlled by the authority responsible for the location.
Mechanical Installation Instructions
Figure 1: Dimensions are for a standard ComNet™one slot module.
Rack Module:
The unit is designed to be installed in the ComNet 19-inch (483-mm) EIA standard card-cage rack, the C1-US,
C1-EU, or the C1-CH. Follow these guidelines to install rack cards after performing module setup procedures.
C1-US, C1-EU, or the C1-CH Card Cage Racks
CAUTION: Although the units arehot-swappable and maybe installed without turning power off to the rack,
ComNet recommends that the power supply be turned off and that the rack power supply is disconnected
from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the
edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel.
Seating may requirethumb pressureon the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card
is seated against the front of the rack.
FDX51M2
Installation Considerations
This fiber-optic link is supplied as
aStandalone/Rack module.
Units should be installed in dry
locations protected from extremes
of temperature and humidity.
Standalone Module:
The unit is provided with a mounting
plate with holes for two No. 6 pan
head screws (3-mm or 3.55-mm).
The type of screws must be suitable
for the surface where a module will
be mounted. (Screws not supplied)
See figure 1.
1. Determine where the module will be
installed, and ensure that there is
adequatespace at both ends for
making the various cable
connections and for reading the
diagnostic LEDs.
2. Attach the module to a flat surface
using two mounting screws.
(Not Supplied)
.156 [3.96 mm]
.313 [7.95 mm]
INS_FDX51M2_REVA
01/27/09
Page 1
FDX51M2
2FIBER RS232/422 DATA LINK
2MULTIMODE
OPTICAL FIBERS
BLACK WITH WHITE STRIPE
BLACK
INSTALLATION INSTRUCTIONS
Communication Networks
3Corporate Drive • Danbury, CT 06810 • USA
Tel: 203-796-5300 • Toll Free: 1-888-678-9427
www.comnet.net
GND
+OUT
-OUT
-IN
+IN
OUT
IN
}RS422 OUT
RS232
OUT
IN
GND
}RS422 IN
}
LEDS: RED = “No Activity”
GRN = “Activity”
NOTE: RED DOES NOT MEAN “Error”
INS_FDX51M2_REVA
01/27/09
Page 2
Power Sources - The product should only be operated from the recommended power source.
Use only a UL Class 2 indoor/dryor Class 3 outdoor/wet power supply.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should beinstalled in a restricted access location; available through the use
of a lock and key or other means of security. Access should be limited to service personnel who
have been instructed about the reasons for the restrictions to the location. Any and all
precautions should betaken and controlled by the authority responsible for the location.

Other Comnet Transceiver manuals

Comnet FDX4DM1A User manual

Comnet

Comnet FDX4DM1A User manual

Comnet FDX60M1A-M User manual

Comnet

Comnet FDX60M1A-M User manual

Comnet FVT1014 User manual

Comnet

Comnet FVT1014 User manual

Comnet FVR15M2 User manual

Comnet

Comnet FVR15M2 User manual

Comnet FDX721SHR User manual

Comnet

Comnet FDX721SHR User manual

Comnet FDX55M1 User manual

Comnet

Comnet FDX55M1 User manual

Comnet FDC24NL[SFP] Series Owner's manual

Comnet

Comnet FDC24NL[SFP] Series Owner's manual

Comnet MLS II User manual

Comnet

Comnet MLS II User manual

Comnet ComNet FVT15M2 User manual

Comnet

Comnet ComNet FVT15M2 User manual

Comnet FDX54 User manual

Comnet

Comnet FDX54 User manual

Comnet FDX4DS1 Series User manual

Comnet

Comnet FDX4DS1 Series User manual

Comnet FDX72 1 Series User manual

Comnet

Comnet FDX72 1 Series User manual

Popular Transceiver manuals by other brands

Delta Electronics LCP-155B4MSRx Series Specification sheet

Delta Electronics

Delta Electronics LCP-155B4MSRx Series Specification sheet

Adeunis RF FIELD TEST DEVICE - sigfox RC2 user guide

Adeunis RF

Adeunis RF FIELD TEST DEVICE - sigfox RC2 user guide

Clegg MARK 3 owner's manual

Clegg

Clegg MARK 3 owner's manual

Cypress WiFi3309701 user manual

Cypress

Cypress WiFi3309701 user manual

Clarion JC-212 Service manual

Clarion

Clarion JC-212 Service manual

Lathem AirTime user manual

Lathem

Lathem AirTime user manual

3Com 1000BASE-SX GBIC installation guide

3Com

3Com 1000BASE-SX GBIC installation guide

Hirschmann Mini-OTDE Description and operating instructions

Hirschmann

Hirschmann Mini-OTDE Description and operating instructions

Nokia RH-27 Series troubleshooting guide

Nokia

Nokia RH-27 Series troubleshooting guide

Radio Shack MTX-103 owner's manual

Radio Shack

Radio Shack MTX-103 owner's manual

Mobile Create MPT-H1 instruction manual

Mobile Create

Mobile Create MPT-H1 instruction manual

Guntermann & Drunck A1990030 installation guide

Guntermann & Drunck

Guntermann & Drunck A1990030 installation guide

Kenwood TK-7108H Service manual

Kenwood

Kenwood TK-7108H Service manual

Technisonic Industries Limited TDFM-136B Quick reference guide

Technisonic Industries Limited

Technisonic Industries Limited TDFM-136B Quick reference guide

Yaesu FT-450 manual

Yaesu

Yaesu FT-450 manual

Icarus Sky connect installation manual

Icarus

Icarus Sky connect installation manual

STE BK77 Operating and service manual

STE

STE BK77 Operating and service manual

Phottix Strato TTL instruction manual

Phottix

Phottix Strato TTL instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.