4.Conguration
4.1 Programming mode
ToconguretheP1000,thereadermustbedisconnectedandreconnected(forabout
2seconds).NowtheMastertranspondercanconguretheP1000’ssettings.Please
seethecongurationschemas// markings.
RemembertoshowtheMasterTransponderwithin10secondstoallowyoutochange
theP1000’sconguration(timeout).
Thefollowingcongurationsonlyworkafterpowero/onasdescribed.
4.2 Settings
These settings can split the outputs, invert the outputs, and set the timeout.
Usetheenclosedcongurationscheme.
4.2.1 OC Split(1ashontheyellowLED)
Fromthefactory,theloadedtagsenablebothoutputs(userspace1to80).This
settingdividestheuserlocations.User1to40activatesoutput2(yellowwire)and
user space 41 to 80 activates output 1 (white wire).
Show master transponder for toggle ( = split, = combined).
4.2.2 OC1 and OC2 inverted(2or3ashesontheyellowLED)
ThesefunctionsinverttheP1000’soutputs(2ashesforoutput1and3ashesfor
output 2).
(= inverted, = not inverted).
5