Continal 39003-tsrf User manual

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Quantum digital
thermostat-RF
The Quantum digital thermostat-RF is stylish, modern, wireless and packed full of app-
controlled features. Recharging is simple via the micro USB port.
Easy to set up and control, this self-learning thermostat can be operated remotely via your
smart device or manually through its intuitive interface.
Contents
1. Before you start
2. LCD icon description
3. Button description
4. Compatibility with other Continal devices
5. First power-up sequence
6. Linking
7. Full menu structure
8. Operating in oine mode
9. Short description of admin settings
10. Error codes
11. Product compliance and safety

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
1. Before you start
Symbols explanation:
S – Volt-free contact
T – Temperature sensor
S1, S2 Terminals:
- Air or oor temperature sensor
- External volt-free contact to connect any
ON/OFF switch or occupancy sensor
S1
S2
T
S
Wall mounting
The ideal position to mount the thermostat is 1.5m above oor level and away from heat sources.
The Quantum digital thermostat-RF should not be exposed to sunlight or any extreme conditions
(including draughts).
123
Mounting: To wall mount the thermostat, use the accessories supplied. (1) The wall plate can be
mounted by using either the supplied (2) self-adhesive mounting tape or (3) the mounting screws.
Once in place, just attach the thermostat (both thermostat and plate have built-in-magnets).
Wiring diagram

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
2. LCD icon description
1. Menu / Settings description + clock
2. AM / PM
3. Temperature unit
4. Heating indicator (animated when demand)
5. Cooling indicator (animated when demand)
6. RF connection indicator
7. Internet connection indicator
8. Occupancy sensor
9. Key lock function
10. Standby mode icon
2
8
9
10111214
15
20
19
18
17
16
1
3
4
5
6
7
13
11. Current temperature / setpoint temperature
12. Holiday mode
13. Temporary override mode
14. Settings icon
15. Status indicator
16. External / oor temperature sensor indicator
17. Schedule programme number
18. Schedule mode icon
19. Day indicator / SET information
20. Current humidity value

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
3. Button description
4. Compatibility with other Continal devices:
Button Function
1) Menu button / return button.
2) In the main screen: press and hold for 3 seconds to change the thermostat
operating mode (schedule mode / permanent mode / temporary override mode).
3) In the settings screen: press and hold for 3 seconds to go back without saving the
changes.
4) In the pairing screen (in system type menu): press and hold for 3 seconds to see
other pairing options.
“Down” button (decrease value / move the menu in the ‘down’ direction).
“Up” button (increase value / move the menu in the ‘up’ direction).
1) Press and hold for 3 seconds to power up.
2) “Ok / tick” button (conrm parameter value / go to the next menu / save settings).
3) Main screen: press and hold for 3 seconds to enter standby mode.
4) Settings screen: press and hold for 3 seconds to go back to the main screen & save all
your changes.
5) During pairing process – hold button for 3 seconds to power o or reboot the
thermostat.
+
In the main screen - press and hold these buttons together for 3 seconds to lock /
unlock the thermostat keypad).
The Quantum digital thermostat-RF can work in online or oine mode.
*Mode selection is available on rst use.
Download the Salus Smart Home app on your iOS or Android device.
Salus Smart
Home app
Online mode
Offline mode
Quantum hub connected.
You can congure and use all
your devices in the Salus Smart
Home app.
Quantum hub not connected.
You can use your devices locally.
This works using the ZigBee
network.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
5. First power-up sequence
6. Linking
Please note: For easy installation, please make sure you have already added your other devices to
the ZigBee network, such as wiring centres etc.
To power on, hold
the button for 3
seconds. The display
will show all icons.
The thermostat will
display the software
version.
Now, choose your
language by using the
or buttons. Conrm
your language using the
button.
123
Refer to the Quantum digital thermostat-RF linking quick guide for instructions on how to link the
Quantum digital thermostat-RF. This can be found at www.continal.eu/quantum
7. Full menu structure
Admin settings:
• Temperature scale
• Display temperature resolution
• Heat control algorithm
• Cool control algorithm
• S1 / S2 input
• Minimum setpoint
• Maximum setpoint
• Valve protection
• Minimum turn-o time
• Optimisation feature
• Comfort warm oor
• Pin code
• Device information
• Factory reset
Schedule settings:
• Disable
• MO-FR+SA-SU
• MO-SU
• Single days
User settings:
• Time / date
• Holiday mode
• Thermostat calibration
• Show / hide display humidity
• Show / hide display floor
• Standby temperature setpoint
• Heat / cool
• Reset user settings

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
8. Operating in oine mode
Conrm by pressing
the button.
Use the or
buttons to set the
temperature.
123
Setting temperature change (manual mode)
The thermostat will
go back to the main
screen.
Setting time / date
Setting the time / date manually can only be done in oine mode. In online mode the Quantum
digital thermostat-RF will automatically synchronise the current time and date.
Go to the user
settings.
Press the button to
enter the main menu.
123
Select the time / date
option.
Use the or
buttons to set the
time.
Select the clock
settings.
45
Use the or
buttons to set the
date.
6

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Enter the schedule
settings.
12
3
Programming mode
Separate schedules
for weekdays and
weekends.
There are 3 possible schedules to choose from.
456
The next programme
will appear, this will
be the lower comfort
temperature. Repeat
steps 4 and 5 for the
next schedules required.
There can be 3 time
periods set within the
schedule. To skip set
periods use --:--. Once
the nal schedule has
been added hold for 3
seconds to save and exit.
Press the button to
enter the main menu.
Seven separate
schedules for single
days.
One schedule for the
whole week.
Programming example shown is for the whole week.
Use the or
buttons to set the
time. Press the
button to conrm.
Use the or
buttons to set
the temperature
setpoint. Press the
button to conrm.
After setting the program, the calendar icon will show on the display.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
4
Holiday mode
Select yes to activate
holiday mode.
Holiday mode will maintain a temperature setpoint for a specic amount of time.
8
Press any button
while in holiday
mode.
To disable holiday
mode, select yes and
press the button
to conrm.
Go to the user
settings.
Press the button to
enter the main menu.
123
Choose the holiday
mode option.
Use the or
buttons to set the
duration (in days).
Press the button
to conrm.
Use the or
buttons to set
the temperature
setpoint. Press the
button to conrm.
7
When holiday mode
is active, this is
shown by the plane.
The thermostat will
show how long is
left on the top of the
display.
To turn o holiday
mode.
45 56

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
3
Display humidity
Select the display
humidity option.
The Quantum digital thermostat-RF has a built-in hygrometer (humidity sensor).
The humidity value can be displayed or hidden.
Go to the user
settings.
Press the button to
enter the main menu.
12
Use the or
buttons to show or
hide the humidity
indication. Press the
button to conrm.
44

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
4
Display oor temperature
The oor
temperature is
displayed with one
degree of accuracy.
Display oor temperature is a function available when using the Quantum oor sensor.
Go to the user
settings.
Press the button to
enter the main menu.
123
Choose the display
oor temperature
option.
Use the or
buttons to show
or hide the oor
temperature. Press
the button to
conrm.
45

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
4
Reset user settings (back to default)
The user settings has
been successfully
reset.
Go to the user
settings.
Press the button to
enter the main menu.
123
Choose the reset
user setting.
Conrm the reset by
selecting yes.
45
Temperature scale: Set the temperature scale to Celsius or Fahrenheit.
Display temperature resolution: Determines the resolution of the displayed temperature
(0.5°C or 0.1°C).
Heat control algorithm: This function defines how to control the room temperature. Choose ITLC for
underfloor heating.
S1 / S2 input: An external temperature sensor or an occupancy sensor can be connected to the S1 / S2
input of the Quantum digital thermostat-RF. Additionally, by connecting a NO type of ON / OFF voltage-
free contact, you can use this input as a one-touch rules trigger (programmed in the Salus Smart Home
app).
Valve protection: This function activates all actuators once a week for 5 minutes (in summer, this
function helps to prevent the actuators sticking).
Min turn-off time: Minimum switch-off time (the thermostat will not send the signal for heating more
often than specified in this parameter).
9. Short description of admin settings

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Optimisation feature: Optimum start and optimum stop functions are an energy saving feature that
makes the thermostat more cost-effective (in combination with the ITCL control algorithm).
Comfort warm floor: This function helps to keep the floor warm, even if the room is warm enough
and there is no need to turn on the heating. You can select 3 levels of warmth. Please note it is not an
economy feature, as your heating system may be on even if there is no heating demand from the room
thermostat. The comfort feature is designed to keep your floor warm all the time.
Device information: In this menu you can check: Software version, RF range value, paired devices or also
activate identification mode.
Factory reset: Here you can reset your device to factory settings. After a successful reset, the device will
be removed from ZigBee network and you will need to add / pair your device again.
Error
code
Display
description Error description Troubleshooting
1. TRV hardware
problem.
TRV paired with
thermostat - TRV
hardware error.
Reinstall the TRV head or replace it. If necessary
contact Coninal.
2. Floor sensor
overheated /
overcooled.
Floor is overheated (in
heating mode).
Floor is overcooled (in
cooling mode).
Set the heating medium temperature or change
oor sensor MAX /
MIN temperature setpoint in the S1/S2 input
admin setting parameter.
Set the cooling medium temperature or change
oor sensor MAX /
MIN temperature setpoint in the S1/S2 input
admin setting parameter.
3. Floor sensor
defect. Floor sensor is broken.
If oor sensor is connected to S1/S2 input, check
the wiring.
If oor sensor is not connected, check the S1/S2
input parameters settings.
4. Floor sensor
defect. Floor sensor is shorted.
If oor sensor is connected to S1/S2 input, check
the wiring.
If oor sensor is not connected, check the S1/S2
input parameters
settings.
Check oor sensor wire insulation for any
damages. Sensor resistance for
25°C=10kΩ.
10. Error codes

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Error
code
Display
description Error description Troubleshooting
5. Connectivity
lost COORD.
Thermostat lost
contact with the
coordinator or the
Quantum hub.
Check the coordinator / Quantum hub power
supply connection.
Force identication process from the coordinator
/ Quantum hub or thermostat.
6. Connectivity
lost WC.
Thermostat lost
connection with the
wiring centre.
Is the wiring centre turned ON and Status
Network LED solid?
If yes, send the heating signal from thermostat to
the wiring centre
(change setpoint temperature).
7. Connectivity
lost TRV.
Thermostat lost
contact with the TRV
head.
Check TRV head batteries.
Send the heating signal from thermostat and
check if the TRV head is working.
If the LED on the TRV head is ashing, repeat the
pairing procedure with thermostat according to
the manual instructions.
8. Connectivity
lost RX 1.
Thermostat has lost
connection with
the boiler receiver
receiver (RX1 mode).
Is the boiler receiver plugged to the power supply
and the top LED is red?
The Auto / Manual switch has to be set to AUTO
position.
Force identication process from the coordinator
/ Quantum hub side and check if the devices are
within the network.
Send the heating signal from thermostat.
If the top LED is ashing, perform the pairing
procedure according to the boiler receiver
manual instruction.
9. Connectivity
lost RX 2.
Thermostat has lost
connection with
the boiler receiver
(RX2 mode).
Is the boiler receiver plugged to the power supply
and the top LED is red?
The Auto / Manual switch has to be set to AUTO
position.
Force identication process from the coordinator
/ Quantum hub side and check if the devices are
within the network.
Send the heating signal from thermostat.
If the top LED is ashing, perform the pairing
procedure according to the boiler manual
instruction.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Error
code
Display
description Error description Troubleshooting
10-17. Connectivity
lost zone 1 - 8.
Wiring centre has
lost connection with
the thermostat of the
given zone:
e.g. 11 = with zone 1;
12 = with the
zone 2 etc. Error is
displayed on all
thermostats.
Check the thermostat power supply.
Send the heating signal from thermostat.
If necessary, reinstall the thermostat.
18. WC / CB lost
connectivity.
Wiring centre has lost
connection with the
coordinator / Quantum
hub.
Error is displayed on all
thermostats.
Is the wiring centre turned ON and status
network LED solid?
Force identication process from the
coordinator / Quantum hub side and check if
wiring centre is within the network.
If LED of the network status is ashing, pair the
wiring centre with the system in accordance to
the manual instruction and pair all thermostats
with wiring centre.
19.
WC / CB lost
link boiler
receiver .
Wiring centre has lost
connection
with the boiler receiver
operating in
RX1 mode.
Error is displayed on all
thermostats.
Is the wiring centre turned on? Status network
LED should be solid.
Force identication process from the
coordinator / Quantum hub side and check if
devices are within the network.
If the LED of the AUTO / MANUAL receiver switch
is ashing, follow the boiler receiver manual
instruction for pairing.
20. Connectivity
lost COORD.
TRV head has lost
connection with
coordinator / Quantum
hub.
Check TRV head batteries (replace if necessary).
Check if the coordinator / internet Quantum hub
is connected to the power supply.
Force identication process from the
coordinator / Quantum hub side and check if
devices are within the network.
Send the heating signal from thermostat.
21. TRV low
battery.
Low battery level in the
TRV head. Replace the TRV head batteries.
22. Unpaired TRV
within range.
TRV head pairing error
or head is
incompatible with the
system.
Remove TRV head from the system and repeat
the pairing procedure with the thermostat.
23. Thermostat
rejected WC.
Thermostat was
rejected by the wiring
centre.
Perform the thermostat’s pairing procedure
again.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Error
code
Display
description Error description Troubleshooting
24. Connectivity
lost.
Thermostat has lost
connection with the
nearest 230V powered
device.
Check the power supply of the nearest 230V
device. If there is problem with RF signal
range, install the ZigBee network repeater
and pair the thermostat with the receiver
again (wiring centre, TRV head etc.)
25 - 28. Connectivity lost
zone 9 - 12.
Wiring centre has
lost connection with
thermostat of the given
zone:
e.g. 26 = with zone 9; 27
= with zone 10;
28 = with zone 11,
29 = with zone 12. Error
is displayed on all
thermostats.
Check the thermostat’s power supply.
Send the heating signal from thermostat.
If necessary, reinstall the thermostat.
29. TRV gear defect.
TRV head has a problem
with the internal gear
mechanism.
Reinstall the TRV head or replace it.
If necessary, contact Continal.
30. TRV failed
adaptation.
Adaptation error of the
TRV head assembled on
the radiator valve
insert.
Check assembly of the TRV head on radiator
valve insert and reinstall the TRV head.
Check the compatibility of the TRV head and
radiator valve insert; replace the valve insert
if necessary.
31. Thermostat low
battery.
Thermostat’s battery
level is low
(error is displayed only in
the Smart Home app).
Replace the thermostat’s batteries.
32. Connectivity lost
boiler receiver
The boiler receiver has
lost connection with
thermostat (error is
displayed only in the
Smart Home app.)
Check the thermostat’s power supply.
Force identication process from the
coordinator / Quantum hub side and check if
devices are within the network.
Send the heating signal from thermostat side
and check if boiler receiver is turning ON.
If the top LED is ashing, perform the pairing
procedure according to the boiler receiver
manual instruction.
Pair thermostat with the boiler receiver
again according to the thermostat’s manual
instruction.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Want more information?
0333 800 1750
www.ufh.co.uk
Product compliance
This product complies with the essential requirements and other relevant provisions of Directives
2014/30/ EU, 2014/35/EU, 2014/53/EU and 2011/65/EU.
868.0-868.6MHz; <13dBm
Safety information
Use in accordance with national and EU regulations. The Quantum 39003-TSRF must be kept dry
and is for indoor use only. Installation must be carried out by a qualied person in accordance
with national and EU regulations. Disconnect your equipment before cleaning it with a dry cloth.
11. Product compliance and safety