manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Continal
  6. •
  7. Thermostat
  8. •
  9. Continal Quantum dial-RF User manual

Continal Quantum dial-RF User manual

Call us today on 0333 800 1750 Visit our website www.continal.co.uk
0333 800 1750

www.continal.co.uk

info@continal.co.uk

UNDERFLOOR HEATING
Linking guide
Quantum dial-RF
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Contents
1. Oine mode
2. Online mode
3. Factory reset
Learn to link your Quantum dial-RF thermostat with your Quantum wiring centre-RF, either
oine or online using the Quantum hub and the Smart Home app.
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Network LED statuses:
(LED is lit steady) - wiring centre is added
to the ZigBee network and paired with the
Quantum coordinator.
(LED is blinking) - wiring centre is not
connected to the network, but it is ready for
pairing with the Quantum coordinator for
the ZigBee network.
Checking the address of the wiring centre.
To check the address of the wiring centre in the ZigBee network, press the Pair
button. The wiring centre number is indicated by the number of LEDs at the zones
(this number is known as the control box number on the Quantum thermostat.)
1. Linking in oine mode
Quantum coordinator
5 sec
To begin linking in oine, hold the button for 5 seconds on the Quantum coordinator on the
Quantum wiring centre-RF. This is located in the top right hand corner as shown below.
The wiring centre set up is now complete. In order for the rest of the set up to work correctly, do not
touch the wiring centre until all the thermostats are connected.
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Installing Quantum dial-RF thermostats
Power up sequence
Linking to the wiring centre
Insert batteries into the Quantum dial-RF thermostat, then use the overlay sticker (initial process
only) to set up the correct zones. (Picture shows the dierence.)
The Quantum dial thermostat-RF has joined the network
once the LED is solid red.
Press the SYNC button for 3
seconds until it ashes red.
1 2
123
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Set the group number
No group = position 1.
Set the zone number
Zone 1 = position 1 – zone 2 = position 2 and so on.
Set the wiring centre number
1WC = position 1 – 2WC position 2 and so on.
Repeat the process with the remaining Quantum thermostats.
123
123
123
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
2. Linking in Online mode
To begin set up in online mode, rst remove the Quantum
Coordinator. If the system has been set up in Oine mode
previously, both the wiring centre and thermostats will
need to be factory reset (Page 7 of this document).
Power on your Quantum hub
Ensure the Quantum hub is connected to the internet and
you have downloaded the Salus Smart Home app on to your
mobile phone or tablet. (See the Quantum hub quick guide.)
5 sec
Complete the linking process
Once the process has been complete, do not disconnect the
wiring centre from the mains for at least 30 minutes. After
this time the thermostats will memorise the locations and will
automatically re-connect if the mains are disconnected.
Connect to the wiring centre
Open your Salus Smart Home app on your mobile device and follow the steps below.
1 2 43
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Name your
wiring centre.
Connect the Quantum thermostat
Open your Salus Smart Home app on your mobile device and follow the steps below to
connect your thermostat. (Thermostats should be connected individually.)
Power on Quantum dial-RF thermostat as seen below
The Quantum dial thermostat-RF has joined the network
once the LED is solid red.
Name the room.
1 2 3
32
1 2 43
Press the SYNC button for 3
seconds until it ashes red.
1
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
Once all the above
steps are complete,
you can now repeat
the process to
add any additional
thermostats to the
system. Once all your
thermostats have
been connected, your
Salus Smart home app
should resemble the
image.
Apply the
thermostat
to the correct
zone.
The thermostat can
be set to default
programme with 2
on times or click no
and set the desired
program.
Set the
desired time
format.
5 6 7
8 9
10 11
Call us today on 0333 800 1750
UNDERFLOOR HEATING
Visit our website www.continal.co.uk
3. Factory reset
Quantum dial-RF thermostat
• Press the menu button
• Ensure all thermostats are reset
• Hold the pair button until G1 & G2 red lights come on and go o again
• Hold the circle button on the Quantum coordinator until the light changes to orange
• Press the Quantum coordinator button again for 5 seconds until it ashes red
• Use a small pin to press the “reset button”
Press the reset button for 5 seconds, then the thermostat will completely reset and remove itself
from the ZigBee network.
Quantum wiring centre-RF
The wiring centre is now reset. Remove the coordinator if connecting to Quantum hub.
If a factory reset is required, each Quantum thermostat will need to be factory reset separately to
the Quantum wiring centre.
1 2
Call us today on 0333 800 1750 Visit our website www.continal.co.uk
Rev: 12/22 © 2022 Continal Group Ltd. All rights reserved. E & OE.
[email protected]
www.continal.co.uk
0333 800 1750
UNDERFLOOR HEATING

Other Continal Thermostat manuals

Continal 39001-TS User manual

Continal

Continal 39001-TS User manual

Continal Quantum dial thermostat-RF User manual

Continal

Continal Quantum dial thermostat-RF User manual

Continal 39003-tsrf User manual

Continal

Continal 39003-tsrf User manual

Continal 39003-tsrf User manual

Continal

Continal 39003-tsrf User manual

Continal Quantum dial thermostat-RF User manual

Continal

Continal Quantum dial thermostat-RF User manual

Popular Thermostat manuals by other brands

Genebre GE-SMART user manual

Genebre

Genebre GE-SMART user manual

Field Controls EvenAir T32 Installation and user manual

Field Controls

Field Controls EvenAir T32 Installation and user manual

Sensi 1F96U-42WF Series Setup guide

Sensi

Sensi 1F96U-42WF Series Setup guide

Pentair Nuheat element quick start guide

Pentair

Pentair Nuheat element quick start guide

Heatit HEATITZ-WAVE Installer manual

Heatit

Heatit HEATITZ-WAVE Installer manual

Aube Technologies RLV4305 owner's manual

Aube Technologies

Aube Technologies RLV4305 owner's manual

Daikin EKWCTRDI1V3 User reference guide

Daikin

Daikin EKWCTRDI1V3 User reference guide

Honeywell T8400C1099 owner's guide

Honeywell

Honeywell T8400C1099 owner's guide

Siemens RDG Application guide

Siemens

Siemens RDG Application guide

jablotron TP-82N quick start guide

jablotron

jablotron TP-82N quick start guide

BBT Thermotechnik MT 10 manual

BBT Thermotechnik

BBT Thermotechnik MT 10 manual

Nexans N-COMFORT TR+ user manual

Nexans

Nexans N-COMFORT TR+ user manual

Saswell SAS900MTK-0 operating instructions

Saswell

Saswell SAS900MTK-0 operating instructions

Lennox icomfort Touch Thermostat Homeowner's manual

Lennox

Lennox icomfort Touch Thermostat Homeowner's manual

CTC Union 71157P user manual

CTC Union

CTC Union 71157P user manual

Honeywell WebStat T7350 installation instructions

Honeywell

Honeywell WebStat T7350 installation instructions

DELTA DORE DELTA 8000 TAP RF installation instructions

DELTA DORE

DELTA DORE DELTA 8000 TAP RF installation instructions

tado° Smart Radiator Thermostat Welcome guide

tado°

tado° Smart Radiator Thermostat Welcome guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.