manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Continental Instruments
  6. •
  7. Controllers
  8. •
  9. Continental Instruments CICP1400UL User manual

Continental Instruments CICP1400UL User manual

SUPERTERM-4
CICP1400UL 4-Door Intelligent Controller
The four-reader Superterm (CICP1400UL) supports
4 readers and has 16 inputs, 1 tamper alarm and 9
outputs. A locking steel enclosure, power supply and
battery are included.
Superterm-4 is an expandable intelligent controller capable of
supporting all access control functions for one to four doors. This
distributed processor-based panel will operate as a standalone
unit in the event server-communications are interrupted. The
Superterm is programmed via Continental Instruments (CIC)
CardAccess®software program, a Windows-based access control
and security management solution. Once programmed, the
controller does not require continuous server communications,
as it automatically stores system transactions in its internal
memory. The Superterm’s memory is field expandable, allowing
for greater cardholder populations and/or a larger transaction
buffer. The controller’s Flash EPROM firmware is easily
upgraded when additional features or system enhancements
are required. All Continental Instrument’s controllers feature
extensive multi-stage lightning/transient protection on-
board for maximum reliability even in harsh environments.
The Superterm accepts industry standard Wiegand output devices
and supports virtually all card/reader technologies. Proximity,
Biometric, Magnetic Stripe, Barcode, Wiegand, Barium Ferrite,
Keypad and Smart Readers are easily connected and controlled.
The Superterm can store multiple card (bit) formats in its internal
memory, making it a cost-effective retrofit panel. Supporting
multiple bit formats allows existing card populations and readers
to remain in place.
Up to 63 CIC Intelligent Controllers (Microterm, Miniterm,
Smarterm or Superterm) can be intermixed on the same
communications network. Multiple communication networks
(ports) can be connected to the CardAccess®server for maximum
system expansion. Controller communication choices include:
hardwire (repeat or multi-drop mode), LAN/WAN, dial-up or
fiber optics for maximum flexibility. Continental Instruments
supports RS232, RS422 and RS485 communication formats for
optimal system configuration.
In addition to memory and power expansion capabilities, the
Superterm will accept up to 3 input/output expansion boards.
The Superterm can be ordered with the expansion boards pre-
installed at the factory. The boards can also be ordered separately
and field installed within the Superterm enclosure. The boards
are mounted to the inside of the hinged enclosure cover. The
Alarm Expander Board provides 16 supervised inputs while
the Relay Expander Board provides 16 relay outputs and 8
unsupervised inputs.
Continental Instruments, A Napco Security Group Company •355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 •FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
Superterm-4 Capacities
Cards 20,000 standard (exp. to 145,000)
Readers (5-wire) 4 (Wiegand output)
Keypads (5-wire) 4 (Wiegand output)
Keypads (7-wire) 4 X-Y Matrix type
Readers
w/Keypad
4 5-wire Readers with 8 or 4 X-Y Matrix Keypads
Standard
Inputs
16 (Supervised)
Expanded
Inputs
48 Additional inputs (Supervised)
Standard
Outputs
9 Form C rated at 3A@24VDC/VAC
Expanded
Outputs
48 Additional Form C rated at 3A@24VDC/VAC
Transaction
Buffer
1000 Standard (exp. to 30,000)
Time Schedules 128
Access Groups 1000
Holidays 50
Reader Power 800mA@5VDC, 500mA@12VDC
Battery Backup 4-6 hours included
Enclosure Size 21.5”H x 21.25”W x 7”D, 48lbs.
UL Listings UL294, UL1076, UL1950**
**UL1950 replaced with EN60950 in Q2/2003
A standard on-board power supply provides 800mA @5VDC
or 500mA@12VDC for reader power. An additional 3A
@12VDC is available with the optional expanded power
supply. The Superterm can be ordered with a factory installed
expanded power supply. The expanded power supply can also
be ordered separately and field installed within the Superterm
enclosure. The expanded power supply includes a 12AH
standby battery, an upgrade to the standard 7AH battery.
The standard 7AH and expanded 12AH batteries provide 4-6
hours standby. In addition to the rechargeable standby battery,
each Superterm includes a lithium battery for up to one year of
data protection.
The Superterm-4 is UL Listed for UL294 (Access Control
System Unit), UL1076 (Proprietary Burglar Alarm Unit) and
UL1950** (Information Technology Equipment).
Typical Door Configuration
See Continental Instruments Configuration Guide for
additional detailed system wiring information.
Continental Instruments, A Napco Security Group Company •355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 •FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
CardAccess®and CI SQL 3000™are trademarks of Continental/NAPCO. © Continental Instruments/NAPCO, 2003.
Door Contact
Electric
Door Strike
Door Lock
Power Supply
RS422 to Panels
Continental
Instruments llc
Re
q
uest to Exi
t
M
o
ti
o
n D
e
t
ec
t
o
r
Door Contact
C
ard Reader
Request
to Exit
B
u
Doo
r
Lock
A or B
G
D
G
G
G
Request
to Exit
G
H
G
NOTE: Request to Exit motion detectors will require
an additional 12VDC power cable. Exit devices are
typically mounted on the egress side of door.
C
ardAccess
3000
D
a
t
abase
a
n
d
C
ommunication
s
S
erve
r
C
I
C
E1
9
4
0
PL-
1
Pollin
g
Line Converte
r
R
S
2
3
2 to R
S
42
2
Required if server is not located
within 5
0
RS422 Re
p
eat Mode Communications Networ
k
4
000
' max. distance between controllers.
U
p
to 63 controllers on a Re
p
eat Mode Network
.
p
erter
m
Su
p
p
p
erter
m
Su
p
p
RS
42
2
x
. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4000'
R
S
2
32
Max.
50'
nit
e
r
m
M
i
i
m
arter
m
Sm
m
C
CICP1400UL Four Door Intelligent Controller
Continental Instrument’s Controllers can connect to the
CardAccess Server via hardwire (shown below), LAN/WAN
dial-up modem or fiber optics. See the CIC Configuration
Guide for additional detailed system information.
Superterm-4 Components
QTY. Part No. Description
1CICP1400UL
or
CICP1400ULEXP
Four (4) reader controller with stan-
dard 20,000 card capacity, 16 super-
vised alarm inputs, tamper alarm, and
9 relay outputs. Unit ships complete
in a locked steel enclosure including a
7AH standby battery for memory and
system operation.
Same as above, with expanded power
supply. Required if more than one Re-
lay Expander Board (CICP1800RB) is
used or additional 12VDC is needed. A
12AH Battery is included.
1Standard 14VAC Power Supply via step-
down transformer mounted inside
enclosure. 10’ power line cable with
110VAC plug is included.
1Standard 7 AH Battery Backup included.
1 Optional CICEXPPWS 12V Linear Expanded Power
Supply provides 3A @ 12VDC
Auxiliary Power. 12AH Battery is
included.
1 Optional CICP1800MB2-1 Memory Board - 2MB (up to 145,000
cardholders).
Up to 3
Optional*
CICP1800RB Relay Expander Board - 16 output
relays, 8 alarm inputs (Unsupervised).
Up to 3
Optional*
CICP1800AB Alarm Expander Board - 16 alarm
inputs (Supervised). UL Listed.
Note: *A maximum of 3 Expansion Boards in any combination may be added to the Superterm
enclosure.
A458

This manual suits for next models

1

Other Continental Instruments Controllers manuals

Continental Instruments CICP1400 User manual

Continental Instruments

Continental Instruments CICP1400 User manual

Continental Instruments CICP1800T User manual

Continental Instruments

Continental Instruments CICP1800T User manual

Continental Instruments CICP1200 User manual

Continental Instruments

Continental Instruments CICP1200 User manual

Continental Instruments CICP1300 User manual

Continental Instruments

Continental Instruments CICP1300 User manual

Continental Instruments CICP1800 User manual

Continental Instruments

Continental Instruments CICP1800 User manual

Continental Instruments CICP1100 User manual

Continental Instruments

Continental Instruments CICP1100 User manual

Popular Controllers manuals by other brands

Siemens SIRIUS MCU 3RK4353-3.R58-0BA0 operating instructions

Siemens

Siemens SIRIUS MCU 3RK4353-3.R58-0BA0 operating instructions

Mitsubishi QD51 Programming manual

Mitsubishi

Mitsubishi QD51 Programming manual

Sunricher SR-2202T2 US manual

Sunricher

Sunricher SR-2202T2 US manual

Danfoss Old ICAD 600 series Instruction

Danfoss

Danfoss Old ICAD 600 series Instruction

Jupiter J100 Hardware manual

Jupiter

Jupiter J100 Hardware manual

mbj CTR-52 operating instructions

mbj

mbj CTR-52 operating instructions

Honeywell 9782 Series Operator's manual

Honeywell

Honeywell 9782 Series Operator's manual

WellMark Top Gun 2001PR Series Installation, operation & maintenance instructions

WellMark

WellMark Top Gun 2001PR Series Installation, operation & maintenance instructions

SOMFY animeo KNX Master Control W2 Instruction

SOMFY

SOMFY animeo KNX Master Control W2 Instruction

Mercoid EDA series Installation and operating instructions

Mercoid

Mercoid EDA series Installation and operating instructions

Danfoss VLT 2800 instruction manual

Danfoss

Danfoss VLT 2800 instruction manual

GReddy e-01 instruction manual

GReddy

GReddy e-01 instruction manual

Bogart Engineering SC-2030 Technical manual

Bogart Engineering

Bogart Engineering SC-2030 Technical manual

Rosslare AC-225E Hardware installation manual

Rosslare

Rosslare AC-225E Hardware installation manual

Green Air Products THC-1 Quick start instructions

Green Air Products

Green Air Products THC-1 Quick start instructions

Hathorn H7 Operator's manual

Hathorn

Hathorn H7 Operator's manual

Tinycontrol GSMKON-030 manual

Tinycontrol

Tinycontrol GSMKON-030 manual

Siemens SIMATIC S5 Series manual

Siemens

Siemens SIMATIC S5 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.