MICROTERM
CICP1100 Single Door Intelligent Controller
The Microterm (CICP1100) has 2 inputs, 1
tamper alarm and 3 outputs, and is housed
in a steel enclosure.
Microterm is a single-door intelligent controller designed to be
installed at or near the protected door. The Microterm is capable
of controlling all access control functions for one door, including
two-reader support. The two-reader configuration is generally
used for in-reader and out-reader applications. It is possible
to use the Microterm’s 2-reader configuration on two separate
doors with certain limitations. This distributed processor-based
panel will operate as a standalone unit in the event server
communications is interrupted. The Microterm is programmed
via CIC CardAccess® software program. Once programmed, the
controller does not require continuous server communications, as
it automatically stores system transactions in its internal memory.
The Microterm (CICP1100) has 2 inputs, 1 tamper alarm and 3
outputs, and is housed in a steel enclosure.
The Microterm accepts industry standard Wiegand output devices
and supports virtually all card/reader technologies. Proximity,
Biometric, Magnetic Stripe, Barcode, Wiegand, Barium Ferrite,
Keypad and Smart Readers are easily connected and controlled.
The Microterm can store multiple card (bit) formats in its internal
memory, making it a cost-effective retrofit panel. Supporting
multiple bit formats allows existing card populations and readers
to remain in place. An optional standby battery is available,
providing 4-6 hours standby power. The Microterm includes a
lithium battery for up to one year of data protection.
Up to 63 CIC Intelligent Controllers (Microterm, Miniterm,
Smarterm or Superterm) can be intermixed on the same
communications network. (A maximum of 31 Microterms
are permitted on each network.) Multiple communication
networks (ports) can be connected to the CardAccess®server for
maximum system expansion. Controller communication choices
include: hardwire (repeat or multi-drop mode), LAN/WAN,
dial-up or fiber optics for maximum flexibility. The Microterm
supports RS232 and RS422 communication formats for optimal
system configuration.
This Intelligent Controller is UL Listed for UL294 (Access
Control System Unit), UL1076 (Proprietary Burglar Alarm Unit)
and UL1950 (Information Technology Equipment).**
Continental Instruments, A Napco Security Group Company •355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 •FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
Microterm Capacities
Cards 1400 standard
Readers (5-wire) 1 or 2 (Wiegand output)
Keypads (5-wire) 1 or 2 (Wiegand output)
Keypads (7-wire) 1 X-Y Matrix type
Readers
w/Keypad
1 5-wire Reader with 1 X-Y Matrix Keypads
Standard
Inputs
2 (Supervised)
Expanded
Inputs
N/A
Standard
Outputs
3 Form C rated at 3A@24VDC/VAC
Expanded
Outputs
N/A
Transaction
Buffer
1000 Standard (exp. to 30,000)
Time Schedules 128
Access Groups 1000
Holidays 50
Reader Power 100mA@5VDC
Battery Backup
4-6 hours (optional)
Enclosure
Size 7.5”H x 7.5”W x 2”D, 2lbs.
UL Listings UL294, UL1076, UL1950**
** UL1950 replaced with EN60950 in Q2/2003
Continental Instruments, A Napco Security Group Company •355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 •FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
CardAccess® and CI SQL 3000™ are trademarks of Continental/NAPCO. © Continental Instruments/NAPCO, 2003.
Door Contact
Electric
Door Strike
Door Lock
Power Supply
RS422 to Panels
Continental
Instruments llc
Re
q
uest to Exi
t
M
o
ti
o
n D
e
t
ec
t
o
r
Door Contact
C
ard Reader
Request
to Exit
B
u
Doo
r
Lock
A or B
G
D
G
G
G
Request
to Exit
G
H
G
NOTE: Request to Exit motion detectors will require
an additional 12VDC power cable. Exit devices are
typically mounted on the egress side of door.
C
ardAccess
3000
D
a
t
abase
a
n
d
C
ommunication
s
S
erve
r
C
I
C
E1
9
4
0
PL-
1
Pollin
g
Line Converte
r
R
S
2
3
2 to R
S
42
2
Required if server is not located
within 5
0
RS422 Re
p
eat Mode Communications Networ
k
4
000
' max. distance between controllers.
U
p
to 63 controllers on a Re
p
eat Mode Network
.
p
erter
m
Su
p
p
p
erter
m
Su
p
p
RS
42
2
x
. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4
000'
R
S
42
2
Max. 4000'
R
S
2
32
Max.
50'
nit
e
r
m
M
i
i
m
arter
m
Sm
m
C
CICP1100 Single Door Intelligent Controller
Continental Instrument’s Controllers can connect to the
CardAccess Server via hardwire (shown below), LAN/WAN
dial-up modem or fiber optics. See the CIC Configuration
Guide for additional detailed system information.
Microterm Components
QTY. Part No. Description
1CICP1100
Stand-alone single- or two-door controller
with standard 1,400 card capacity, 2 alarm
inputs, tamper alarm, 3 relay outputs and
printer output. Unit ships complete in a steel
enclosure.
1Standard
12VDC Wallmount Power Supply included.
1Standard
15-conductor wiring Harness included.
1 Optional CICP1100BAT-2
CICP1100BAT-2 Battery Standby - Input
120VAC, Output 12VDC to temporary power
the Microterm only in the event of a power
failure.
Typical Door Configuration
See Continental Instruments Configuration Guide for
additional detailed system wiring information.
A431A

This manual suits for next models

1

Other Continental Instruments Controllers manuals

Continental Instruments CICP1300 User manual

Continental Instruments

Continental Instruments CICP1300 User manual

Continental Instruments CICP1800T User manual

Continental Instruments

Continental Instruments CICP1800T User manual

Continental Instruments CICP1800 User manual

Continental Instruments

Continental Instruments CICP1800 User manual

Continental Instruments CICP1400UL User manual

Continental Instruments

Continental Instruments CICP1400UL User manual

Continental Instruments CICP1200 User manual

Continental Instruments

Continental Instruments CICP1200 User manual

Continental Instruments CICP1400 User manual

Continental Instruments

Continental Instruments CICP1400 User manual

Popular Controllers manuals by other brands

LinMot E1250-EC-UC user manual

LinMot

LinMot E1250-EC-UC user manual

Renogy Wanderer Li 30A 12V PWM user manual

Renogy

Renogy Wanderer Li 30A 12V PWM user manual

Erreka ROLL 60C Installation instruction

Erreka

Erreka ROLL 60C Installation instruction

Servomech ATL 50 Installation, operation and maintenance manual

Servomech

Servomech ATL 50 Installation, operation and maintenance manual

Deif AGC 150 installation instructions

Deif

Deif AGC 150 installation instructions

SMC Networks 10-AW Series quick start guide

SMC Networks

SMC Networks 10-AW Series quick start guide

Zamel RZB-03 instruction manual

Zamel

Zamel RZB-03 instruction manual

3Ware 9000 Series specification

3Ware

3Ware 9000 Series specification

FASAR ELETTRONICA FE1052 manual

FASAR ELETTRONICA

FASAR ELETTRONICA FE1052 manual

GE ASTAT XL Series Testing, troubleshooting and servicing instructions

GE

GE ASTAT XL Series Testing, troubleshooting and servicing instructions

Lippert Components 13398-C1 Operation and service manual

Lippert Components

Lippert Components 13398-C1 Operation and service manual

Aruba 6000 series installation guide

Aruba

Aruba 6000 series installation guide

Beta 1498CM/12 Instructions for use

Beta

Beta 1498CM/12 Instructions for use

AMALGAMATED INSTRUMENT RM4-IV Operation and instruction manual

AMALGAMATED INSTRUMENT

AMALGAMATED INSTRUMENT RM4-IV Operation and instruction manual

Intersil ISL8088EVAL1Z Application note

Intersil

Intersil ISL8088EVAL1Z Application note

THORLABS PIA Series user guide

THORLABS

THORLABS PIA Series user guide

Compac DCA Installation & service manual

Compac

Compac DCA Installation & service manual

AUMA SA-UW Operation instructions

AUMA

AUMA SA-UW Operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.