Control Data Corporation 5R2A5 User manual

CONTROL
DATA®
DISK
STORAGE
UNIT
5R2A5
6ENERAL
DESCRIPTION
OPERATION
INSTALLATION
AND
CHECKOUT
THEORY
OF
OPERATION
MAINTENANCE
CONTROL
DATA
C
OR
P0
RATION
CUSTOMER
ENGINEERING
MANUAL

REVISION
RECORD
REVISION
DESCRIPTION
01
Preliminary
edition.
(3—1—71)
A
Manual
released.
This
edition
supercedes
all
previous editions.
(7—28—71)
B
Incorporates
Engineering
Change
Orders
PE29151, PE29419, PE29440,
and
Technical
Corrections
(9—17—71)
affecting
pages
ii,
iii,
viii,
1—3,
2-4,
2—7, 2—8, 2—9,
3-2,
3—7,
3—8,
3—9,
4—12, 4—13, 4—22,
4—23,
4-24,
4—25,_4-26,_4-28,_4—30,_6-1,_6—2,_6—18,_6—19,_6-20,_6-21,_6—31,_6—32,_6—32.1,_6—41,
Comment
Sheet.
C
Incorporates
Engineering
Change
Order
PE29476/Field
Change
Order
PE29479
affecting
pages
(10- 1-71)
Ii,
iii,
iv,
6-24,
6-29, 6-30, Comment
Sheet.
D
Incorporates
Engineering/Field
Change
Order
PE29504
affecting
pages
ii,
Iii,
iv,
6-30,
6-33,
6-34,
(12-17-7
1)
Comment
Sheet.
E
Incorporates
Field
Change
Order
PE29502
affecting
pages
II,
Iii,
iv,
6-7,
Comment
Sheet.
(2—25-72)
F
Incorporates
Technical
Corrections
affecting
pages
II,
lii,
lv,
vii,
viii,
Ix,
3-1, 6-3, 6-4,
6-5,
(4-13-72)
8-6,
6-7, 6-8,
6-9,
6-10, Comment
Sheet.
G
Incorporates
Engineering
Change
Order
PE3
1156/Field
Change
Order
PE3ll57
and
Technical
(9—7—72)
Corrections
affecting
pages
ii,
iii,
iv,
6-5,
6—6,
6-25,
6—27.
H
Incorporates
Engineering
Change
Order
PE3
1283/Field
Change
Order
PE3
1297
affecting
pages
(12—21—72)
ii,
ill,
iv,
6—25, 6—27.
J
Incorporates
Engineering
Change
Order
PE3
1317
documenting
BR2A5A,
60
lIz
units
and
Technical
(2—2—73)
Corrections
affecting
pages
ii,
lii,
iv,
viii,
ix,
1-3,
2-4,
2—5,
2-7,
3-3,
3-6,
4-26,
6-1,
6-2,
6-5,
6—15,
6—18, 6—19,
6—20, 6—21,
6-22,
6—23,
6—29,
6—30,
6-31,
6—32,
6—34,
6-37, 6-39,
6—42,
6-43,
6-44, 6-49.
Page
6-32.1
deleted.
K
Incorporates Engineering/Field
Change
Order
PE3
1594
and
Technical
Corrections
affecting
pages
(3-10—74)
ii,
iii,
iv,
viii,
4—23,
4—24,
4—26, 6—24,
6—48,
6-48.1.
L
Technical
changes
affecting
pages; ii.
iii.
Iv.
6-50.
6-51.
6-53.
(8—16—74)
Publication
No.
70614600
©
1971. 1972, 1973,
1974
by
Control
Data
Corporation
Printed
in
the
United
States
of
America
Address
comments
concrning
this
manual
to:
Control
Data
Corporation
Technical
Publications
Department
7801
Computer
Avenue
Minneapolis,
MN
55435
or use
Comment
Sheet
In
the
back
of
this
manual.
0
11
70614600
L

C
PUBLICATION
NO.
PUBLICATION
TITLE
MANUAL
STATUS
CHECK
SHEET
70614600
Sheet
1
of
2
BR2A5
Disk
Storage
Unit
Maintenance
REVISION
Manual
PAGE NUMBER REV
Cover
-
Title
Page
-
ii
L
iii
L
iv
L
v
A
vii
F
viii
K
ix
J
Section
1
-
1-1
A
1-2
A
1-3
J
Section
2
-
2-1
A
2-2
A
2-3
A
2-4
J
2-5
J
2-6
A
2-7
J
2-8
B
2-9
B
2-10
A
Section
3
-
3-1
F
3-2
B
3-3
J
3-4
A
3-5
A
3-6
J
3-7
B
3-8
B
3-9
B
PAGE
NUMBER
REV
Section
4
-
4-1
A
4-2
A
4-3
A
4-4
A
4-5
A
4-6
A
4-7
A
4-8
A
4-9
A
4-10
A
4-il
A
4-12
B
4-13
B
4-14
A
4-15
A
4-16
A
4-17
A
4-18
A
4-19
A
4-20
A
4-21
A
4-22
B
4-23
K
4-24
K
4-25
B
4-26
K
4-27
A
4-28
B
4-29
A
4-30
B
4-31
A
4-32
A
PAGE NUMBER
REV
4-33
A
4-34
A
4-35
A
4-36
A
4-37
A
4-38
A
4-39
A
4-40
-
A
4-41
A
4-42
A
4-43
A
4-44
A
4-45
A
Section
5
-
Section
6
-
6-1
J
6-2
J
6-3
F
6-4
F
6-5
J
6-6
G
6-7
F
6-8
F
6-9
F
6-10
F
6-11
A
6-12
A
6-13
A
6-14
A
6-15
J
6-16
A
6-17
A
6-18
J
PAGE
NUMBER
REV
6-19
J
6-20
J
6-21
J
6-22
J
6-23
J
6-24
K
6-25
Fl
6-26
A
6-27
H
6-28
A
6-29
J
6-30
J
6-31
J
6-32
J
6—33
D
6-34
J
6-35
Al
6-36
Aj
6-37
Ji
6—38
A
6-39
J
6-40
A
6-41
B
6-42
J
6-43
J
6-44
J
6-45
A
6-46
A
6-47
A
6-48
K
6-48.
1
K
6-49
J
•
6-50
L
70614600
L
111

PUBLICATION
NO.
PUBLICATION
TITLE
MANUAL
STATUS
CHECK
SHEET
70614600
Sheet
2
of
2
BR2A5
Disk
Storage
Unit
Maintenance
Manual
REVISION
L
PAGE
NUMBER REV
6-51
L
6-52
6-53
L
6-54
A
6-55
A
6-56
A
6-57
A
6-58
A
PAGE
NUMBER
REV
6-59
A
Sec7,8,
9,
10
-
Cmt
Sht
-
Return
Env
-
BackCover
-
C
C
C
iv
70614600
L

PREFACE
Customer
engineering
material
for
the
CONTROL
DATA®
BR2A5
Disk
Storage
Unit
is
contained
in
three
separate
manuals
and
provides
all
information
needed
to
install,
operate,
and
maintain
the
unit:
Publication
No.
70614600
General
Description,
Operation,
Installation
and Checkout,
Theory
of
Operation,
Maintenance
Publication
No.
70614700
Diagrams,
Maintenance
Aids,
Wire
Lists
Publication
No.
70614800
Illustrated
Parts
List
70614600
A


CONTENTS
1.
GENERAL
DESCRIPTION
Introduction
1-1
Equipment
Specifications
1-2
2.
OPERATION
Controls
and
Indicators
Operating
Instructions
DSU
Power
Application
Disk
Pack
Installation
Disk
Pack
Removal
3.
INSTALLATION
AND
CHECKOUT
Uncrating
Space
Allocation
Leveling
and
Aligning
Cabling
and
Connections
Cabinet
Intracabling
Input/Output Cables
Power
Cables
Ground
Bond
Cabinet
Accessories
Input
Power
Requirements
Environment
Initial
Checkout
and
Startup
Procedure
4.
THEORY
OF
OPERATION
Functions
First
Seek
Direct
(Forward/Reverse)
Seek
Return
to
Zero
Seek
(RTZS)
Read/Write/Erase
Assemblies
Power
Supply
AC
/DC
Distribution
Power-On
Sequence
Power-Off
Sequence
Logic
Chassis
Deck
Assembly
Drive
Motor
Assembly
Hysteresis
Brake
Assembly
Spindle
Assembly
Actuator
Transducers
Track
Servo
Disk
Cleaner
Assembly
Blower
System
Disk
Pack
6.
MAINTENANCE
Maintenance
Tools
Maintenance
Materials
Preventive
Maintenance
General
Preventive
Maintenance
Index
Inspect
Actuator Assembly
Clean
Front
Cover
Glass
Change
Primary
Filter
Check
Power
Supply
Outputs
Inspect
and
Clean
Read/Write
and
Servo
Heads
Clean
Shroud
and
Spindle
Clean
Pack
Cleaning
Brushes
Clean
and
Lubricate
Lockshaft
Replace
Absolute
Filter
2-1
2-8
2-8
2-9
2-10
3-1
3-2
3-2
3-2
3-2
3-4
3-6
3-6
3-6
3-6
3-7
3-7
4-
1
4-12
4-13
4-21
4-22
4-23
4-23
4-23
4-25
4-27
4-28
4-29
4-29
4-31
4-31
4-33
4-39
4-40
4-41
4-44
4-45
6-1
6-2
6-2
6-2
6-3
6-3
6—3
6-4
6-5
6-6
6-7
6-7
6-8
6-8
70614600
F
vii

C
Corrective
Maintenance
CDC
Pack
Cleaning
Procedure
Read/Write
and
Servo
Heads
Check
Head/Arm
Adjustment
Head/Arm
Removal
Replacement
Adjacent
Track
Erase
Check
Tuned
Amplifier
Check
and
Adjustment
Drive
Belt
Removal
and
Replacement
Drive
Motor
Removal
and
Replacement
Drive
Motor
Pulley
Removal
And
Replacement
Hysteresis
Brake
or
Felt
Removal
and
Replacement
Spindle
Lock
Pawl
Check
Adjustment
Pack-On
Switch
Check
and
Adjustment
Removal
and
Replacement
Ground
Spring
Check
and
Adjustment
Spindle
and
Lockshaft
Assembly
Lockshaft
Removal
and
Replacement
Spindle
and
Lockshaft
Assembly
Removal
and
Replacement
Index
Sensor
Assembly
Sensor
Stop
Check
and
Adjustment
Index to
Burst
Check
and
A
djustment
Index
Transducer
Removal
and
Replacement
Transducer
Output
Check
Shroud
Adjustment
Disk
Cleaner
Assembly
Check
Adjustment
Removal
and
Replacement
Head
Select
Preamplifier
Card
Removal
and
Replacement
Heads
Loaded
Switch
Check
Removal
and
Replacement
Velocity
Transducer
Check
Removal
and
Replacement
Carriage
Alignment
DC
Offset
Check/Adjustment
Track
Servo
Amplitude
Adjustment
Power
Amplifier
Check!
Adjustment
Velocity
Gain
Check
Adjustment
Fine
Position
Gain
Check!
Adjustment
Integrator
Gain
Check/
Adjustment
Servo/Filter
Balance
Check!
Adjustment
Troubleshooting
6-57
Track Pulse
Troubleshooting
Access Troubleshooting
6-9
6-9
6-9
6-10
6-14
6-19
6-20
6-23
6-25
6-27
6-27
6-29
6-29
6-29
6-29
6-29
6-30
6-30
6-31
6-31
6-32
6-34
6-34
6-35
6-37
6-38
6-38
6-39
6-39
6-39
6-41
6-41
6-42
6-42
6-43
6-43
6-43
6-44
6-46
6-47
6-48.
1
6-48.
1
6-50
6-50
6-53
6-55
C
C
C
C
C
C
C
C
6-57
6-58
viii
70614600
K
C

FIGURES
2-1
Controls
and
Indicators
3-1
Cabinet
Intracabling
Diagram
3-2
System
Intercabling
4-
1
Input/Output
Signal
Gating
4-2
Select
Sequence
4-3 Block
Diagram
4-4 Servo
Circuit
Block
Diagram
4-5
Typical Servo
Signal
Relationships
4-6
Fine
Position
Servo
Signals
4-7
Power
Supply
-
AC/DC
Distribution
4-8
Power
Supply
-
Sequencing
4-9
Deck
Assembly
4-10
Spindle
Assembly
4-11
Actuator
Assembly
Elements
4-12
Head
Loading
4-13
Head/Arm
Assembly
Motion
4-14
Index/Sector
Detection
4-15
Velocity
Detection
4-16
Track
Servo
Dectection
4-17
Track
and
EOT
Pulses
4-18
Blower
System
6-1
Cabinet
Filters
6-2
Pack
Cleaning
Brushes
6-3
Head
Identification
6-4
Head
Adjustment
Trace
6-13
6-5
Head/Arm
Assembly Adjustment
6-15
6-6
Head/Arm
Replacement
6-16
6-7
Head/Arm
Installation
or
Removal
6-17
Symmetry
Adjustment
6-20
Read
Oscillator
Output
Waveform
6-21
Symmetry
Strobe
Relation
6-22
Main
Deck
Underside
6-24
Motor
and
Brake
Assembly
6-26
Index
Sensor
6-33
Index
to
Burst Period
6-36
Detector
Trace
6-37
Index
Transducer
Trace
6-38
Disk
Cleaner
Adjustment
6-40
Read/Write
Head
Cable
Connections
6-42
6-18
Velocity
Transducer
Replacement
6-45
6-19
Carriage
Alignment
6-47
6-20
Power Amplifier
Adjustment
6-49
6-21
Velocity
Gain
Adjustment
6-51
6-22
Fine
Position
Gain
Adjustment
6-52
6-23
Integrator
Gain
Adjustment
6-55
6-24
Servo
Filter
Balance
Adjustment
6-56
TABLES
2-1
4-2
Servo
Circuit
Functions
4-17
6-i
Read/Write
Head
Replacement
3-5
Data
6-18
4-4
I
6-8
6-9
6-9.1
6-10
6-li
6-12
6-13
6-14
6-15
6-16
6-17
2-7
3-3
3-4
4-2
4-2
4-3
4-15
4-16
4-21
4-24
4-26
4-30
4-32
4-34
4-36
4-38
4-40
4-40
4-42
4-43
4-44
6-4
6-8
6-12
2-1
Controls
and
Indicators
3-1
Input/Output Connector
Pin
Assignments
4-1
Input/Output
Lines
70614600
J
ix

C
C
CI
C

SECTION
1
GENERAL
DESCRIPTION
4A


GENERAL
DESCRIPTION
INTRODUCTION
The
CONTROL
DATA
®
Disk
Storage
Unit
is
a
high
speed,
random
access,
data
storage
device
that
interfaces
with
a
central
processor
via
a
control
unit.
The
electro-mechanical
Disk
Storage
Unit
(DSU)
positions
its
read/write
heads
to
discrete
positions
or
tracks
over
spinning
disk
surfaces.
Data,
in
the
form
of
magnetized
bits
or
spots,
is
written
on
or
read
from
the
disk
surfaces
by
the
read/write
heads.
The
disk
pack
assemblies
used
by
the
DSU
provide position
feedback
from
specially
recorded
tracks
on
one
surface
of
the
disk
pack.
The
deck
assembly
contains
the
access
mechanism that positions
the
read/write
and
track
servo
heads,
as
well
as
five Silicon
Peripheral
Logic
(SPL)
cards
involved
in
track
detection
and
Read/Write
operations.
This
assembly also
includes
spindle
assembly,
spindle
drive motor,
and
shroud, the
mounting
and
operational
facilities
required
by
the
disk pack.
The
shroud
surrounds
the disk
pack
and
thereby minimizes
the
possibility
of
damage
to
the
read/write
heads
and
disk
surfaces
caused
by
ingestion
of
dust.
A
hinge-mounted
logic
chassis
assembly
is
the mounting
point
for
the
main
complement
of
the
logic
cards
used
by
the
deck:
five
cards
are
mounted
on
the
deck
assembly.
Cards
for
the
cabinet
are
mounted
in
four
rows
(A
through
D).
This
assembly
also
contains
a
maintenance
panel
which
provides
jacks
to
monitor
logic
voltages,
a
switch/lamp
combination
to
analyze
the
unit
status
and
switches
to
control
the
DSU
operational
status.
A
solid-state
power
supply
assembly
provides
±
5,
±
20,
±
36,
and
+40-vdc
outputs.
70614600A
1-1

C
C
A
frame
assembly
provides
the
required
mounting-structure
for
the
previously
mentioned
assemblies.
In
addition
to
the
structural
elements,
this
assembly
contains
the
operator
controls
for
the
deck
and
a
blower
assembly.
The
output
of
the
blower
assembly is
ducted
to
the
deck
assembly
to
provide
positive
pressurization
of
the
disk pack
and
shroud
area.
It
also
provides
cooling
air
to
the
power
supply
and
logic
chassis.
-
EQUIPMENT SPECIFICATIONS
ACCESSING
TIME
C
Maximum
Access
Time
70
ms
Maximum
One-Track
Access
Time
10
ms
Average
Access
Time
35
ms
C
RECORDING
Mode
Double
frequency
Density
(nominal)
1530
bpi
(outer
track)
2220
bpi
(inner
track)
Bit
Rate
(nominal)
2.
50
MHz
Data
Transfer
Rate
312,
500
characters/second
Bits
/Character
8
Character/Track
7,
812
(J
Tracks
/Cylinder
19
Cylinders
/DSU 400
+
6
spares
DSU/System
8
maximum
DATA
CAPACITY
C’
Bits/Track
62,
500
nominal
Bits
/Cylinder
1,
187,
500
nominal
Bits/DSU
475,
000,000
nominal
C
C
L
1-2
70614600
A
C

DISK
PACK
Disks/Disk
Pack
Useable Recording
Surfaces
/Disk
Pack
Disk Surface
Diameter
Recording
Diameters
Disk
Surface
Coating
Disk
Pack
Velocity
READ/WRITE
HEADS
Heads/Unit
Read/Write Track
Width
Erase
Track
Width
Track
Spacing
Read/Write
to
Erase
Gap
PHYSICAL
-
EACH
CABINET
11
19
14
inches
Track
405
(Inner)
8.
760
inches
nominal
Track
0
(Outer)
13.
200
inches
nominal
Magnetic
Oxide
2400
*
2%
rpm
19
0.
004
inch
nominal
0.
0055
inch
nominal
0.
00505
inch
nominal
0. 045
inch
nominal
Height
Width
Depth
Weight
ELECTRICAL
38
inches
(96.
52
cm)
27
1/2
inches (69.85
cm)
37
1/2
inches (95.25
cm)
660
pounds
(299.
38
kg)
Power
Source
Operating
Current
Standby
Current
Surge
Current
208
volt
(±10%)
BR2A5A
60
±0.
6
Hz,
BR2A5B
50
±0.
5
Hz,
three-phase
(two
legs
used)
7
amps
3
amps
22
amps
I
INPUT/OUTPUT
CONNECTIONS
One
connector per
cabinet
located
below
logic
chassis.
Pin
assignment according
to
Table
3-
1.
Connections
according
to
Figure
3-2.
1—3
70614600
J


SECTION
2
OPERATION


OPERATION
CONTROLS
AND
INDICATORS
The
DSU
contains
a
number
of
panels
and
indicators.
Figure
2-1
locates
the
panels
and
the
indicators
on
a
typical
cabinet
of
the
DSU.
A
functional
description
of
the
controls
and
indicators
is
given
in
Table 2-1.
Descriptions
assume
that
AC
power
is
applied
to
the
unit
by
the
controller.
TABLE
2-1.
CONTROLS
AND
INDICATORS
Control
Or
Indicator
I
Function
Operator
Panel
START
switch/indicator
Switch
energizes
(when
pressed
to
light)
spindle
drive
motor
and
begins
the
First
Seek
sequence
provided
the following
conditions
are
met:
1.
Disk
pack
is in
place
and
cannister
removed.
2.
Front
and
top
covers
are
closed.
3.
Proper
circuit
breakers
are
on.
4.
DC
switch
is
on.
Lights
when
switch is
on
even
if
one
or
more
of
the
above
conditions
is
not
met.
This
allows
operator
to
know
which
units
will
begin
power-on
sequence
when
the
above
conditions
are
met.
Switch
causes
a
power-off
sequence
when
pressed
with
the
indicator
lighted.
70614600
A
2-1

C
TABLE
2-1.
CONTROLS
AND
INDICATORS
(Cont’d)
C
WARTUNG
(MAINTENANCE)
indicator
SCHREIBEN
GESPERRT
(WRITE
LOCKOUT)
switch/indicator
FEHLER
(FAULT)
switch/indicator
BEREIT
indicator
lights
when
Operable
signal
is
being
sent
from
the
DSU
to
the
control
unit.
The
following
conditions
must
be
met
for
the
unit
to
originate
an
Operable
signal:
1.
Heads
loaded.
2.
No
fault
conditions.
3.
Up
to
speed
(spindle
rpm
greater
than
2200)
4.
Logic
Number
plug
installed.
5.
Unit
is
on
line.
6.
COP
signal
from
control
unit
is
at
-30
volts.
WARTTJNG
indicator
lights
when
either
the
logic
chassis
maintenance
panel
DC
switch
is
set
to
OFF
or
the
ON
LINE/OFF
LINE
switch is
set
to
OFF
LINE.
Switch
(when
pressed
to
light)
inhibits
the
ability
of
the
related
DSU
to
perform
a
write
operation.
Switch
removes
the
inhibit
condition
when
pressed
with
the
indicator
lighted.
Lights
when
one
or
more
of
the
following
unwanted
conditions
occur:
1.
More
than
one
head
is selected.
2.
Read
and
Write
Selects
exist
at
the
same
time.
3.
Read
and
Erase
Selects
exist
at the
same
time.
4.
Erase
is
selected
with
no
write
driver.
5.
Erase
is
selected
with
both
write
drivers.
6.
Either
one
or
both
write
drivers are
on
with
no
erase.
7.
Read,
write,
or
erase
is
selected
without
an
On
Cylinder
signal.
BEREIT
(READY)
indicator
Control
Or
Indicator
Function
C,
C
C
C
C
C
2-2
70614600
A
This manual suits for next models
1
Table of contents
Other Control Data Corporation Storage manuals
Popular Storage manuals by other brands

Dell
Dell PowerVault ML6000 Getting started guide

Seagate
Seagate Momentus ST9120414AS product manual

ATTO Technology
ATTO Technology FastStream SC 7500 Technical specification

Addonics Technologies
Addonics Technologies JCCHDIF128 user guide

Sun Microsystems
Sun Microsystems StorEdge 6920 System Regulatory and safety information

Seville Classics
Seville Classics UltraHD UltraGuard WEB347 Assembly instructions