691
LIGHTING INVERTERS
COOPER LIGHTING
COOPER LIGHTING - SURE-LITES®
• Input 120 or 277VAC
1 phase 2 wire
• Custom voltages available
• Electronic and magnetic
ballast compatible
• Generator compatibility
• Forced air cooling only
during emergency
operation, no filters
required
• 90 minute runtime standard;
other runtimes available
upon request
• 98% efficient PWM/IGBT
technology with micro-
processor control
• User programmable with
password protection
• Self-Testing and Self-
Diagnostic with Event, Test
and Alarm Logs
• RS232 communications port
• UL 924 listed
LIFEWAY II
SINGLE PHASE
CSERIES
1.5-16.7 KVA
HID, Fluorescent and
Incandescent
ON-LINE POWER
INVERTER SYSTEMS
DIMENSIONS DESCRIPTION
The Sure-Lites Lifeway II C
Series is a single phase
inverter that provides
uninterrupted power. This
pulse width modulated
inverter utilizes IGBT
technology and has a 2
millisecond transfer time. The
unit’s operating efficiency is
98%, well above a typical fast
transfer inverter. The C Series
inverter is UL 924 Listed and
meets NFPA 101 requirements
by providing 90 minutes of
illumination for emergency
egress lighting. Other run
times and voltages are
available. Please consult your
Cooper Lighting
Representative.
A
BC
Height Width Depth
ABC
47" 30" 25"
SPECIFICATION DATA
Input Voltage 120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages.
Input Frequency 60Hz, ±3%
Input Protection Input Circuit Breaker
Input Harmonic Distortion <10%
Input Power Factor 0.5 lag/lead
Output Voltage 120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages.
Static Voltage Load current change ±2%, battery discharge ±12.5%
Dynamic Voltage ±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3
cycles
Output Harmonic Distortion <3% THD for linear load
Output Frequency 60 Hz. ±0.05Hz during emergency mode
Load Power Factor 0.5 lag to 0.5 lead
Inverter Overload 125% for 5 minutes
Output Protection Optional Distribution Circuit Breakers
Battery 10 Year Valve-regulated Sealed Lead Calcium (standard)
Environmental
Altitude <10,000 feet without derating
Operating Temp. System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating,
20° to 30°C (68° to 86°F), includes battery performance wich can be affected by
temperature. Contact factory for details.
Storage Temp. -20° to 70°C (Electronics Only)
Humidity <95% (non-condensing)
LIFEWAY II SINGLE PHASE C SYSTEM PART NUMBER / RATING / MECHANICAL SPECIFICATIONS
Part Pwr Rtg Pwr Rtg Effic. Audible Heat Loss UPS Cabinet Dimensions UPS Battery Battery Battery Battery Cabinet Dimensions No. of Total Total
Number kVA kW @ full load Noise BTU Width Height Depth Weight Voltage Current Run Width Height Depth Battery No. of System
% db@1m in/cm in/cm in/cm lb/kg VDC Amperes Minutes in/cm in/cm in/cm Cabinets Cabinets Weight (lb/kg)
ISC015 1.5 1.5 98 45 75 30/77 47/120 25/64 250/114 48 39 90 na2na2na2na21 546/249
ISC022 2.25 2.25 98 45 100 30/77 47/120 25/64 265/121 72 38 90 na2na2na2na21 709/323
ISC030 3.0 3.0 98 45 160 30/77 47/120 25/64 295/134 96 38 90 na2na2na2na21 887/403
ISC037 3.75 3.75 98 45 200 30/77 47/120 25/64 305/139 120 37 90 na2na2na2na21 1045/475
ISC048 4.8 4.8 98 45 245 30/77 47/120 25/64 315/143 144 40 90 na2na2na2na21 1203/546
ISC060 6.0 6.0 98 45 300 30/77 47/120 25/64 350/159 180 40 90 30/77 47/120 25/64 1 2 1670/759
ISC080 8.0 8.0 98 45 400 30/77 47/120 25/64 375/171 240 39 90 30/77 47/120 25/64 1 2 2087/949
ISC100 10.0 10.0 98 45 500 30/77 47/120 25/64 435/198 144 82 90 30/77 47/120 25/64 2 3 2631/1195
ISC125 12.5 12.5 98 45 660 30/77 47/120 25/64 465/211 180 82 90 30/77 47/120 25/64 2 3 3105/1409
ISC167 16.7 16.7 98 45 840 30/77 47/120 25/64 530/241 240 80 90 30/77 47/120 25/64 2 3 3954/1795
ORDERING INFORMATION
SAMPLE NUMBER: ISC037120120
Series
ISC=Single
Phase C
Voltage Input
120
277
ISC
KVA Rating Voltage Output
120
277
015=1.5
022=2.25
030=3.0
037=3.75
048=4.8
060=6.0
080=8.0
100=10.0
125=12.5
167=16.7
Options
See page 693 for options

Other Cooper Lighting Indoor Furnishing manuals

Cooper Lighting Paralux III EP3GAX Series User manual

Cooper Lighting

Cooper Lighting Paralux III EP3GAX Series User manual

Cooper Lighting P5 M120 E5SR User manual

Cooper Lighting

Cooper Lighting P5 M120 E5SR User manual

Cooper Lighting Shaper 689 Series User manual

Cooper Lighting

Cooper Lighting Shaper 689 Series User manual

Cooper Lighting Shaper 695-WP-DB Series User manual

Cooper Lighting

Cooper Lighting Shaper 695-WP-DB Series User manual

Cooper Lighting 477 User manual

Cooper Lighting

Cooper Lighting 477 User manual

Cooper Lighting 1433 User manual

Cooper Lighting

Cooper Lighting 1433 User manual

Cooper Lighting IMI-434 User manual

Cooper Lighting

Cooper Lighting IMI-434 User manual

Cooper Lighting Lumiere Westwood 913 User manual

Cooper Lighting

Cooper Lighting Lumiere Westwood 913 User manual

Cooper Lighting Fail-Safe X10 User manual

Cooper Lighting

Cooper Lighting Fail-Safe X10 User manual

Cooper Lighting AMETRIX 1269 User manual

Cooper Lighting

Cooper Lighting AMETRIX 1269 User manual

Cooper Lighting 80-IW User manual

Cooper Lighting

Cooper Lighting 80-IW User manual

Cooper Lighting LV2060ISMulti-Lamp Luminaire LV2060IS User manual

Cooper Lighting

Cooper Lighting LV2060ISMulti-Lamp Luminaire LV2060IS User manual

Cooper Lighting NEO-RAY 7VCR User manual

Cooper Lighting

Cooper Lighting NEO-RAY 7VCR User manual

Cooper Lighting FWE User manual

Cooper Lighting

Cooper Lighting FWE User manual

Cooper Lighting FAIL-SAFE FWS User manual

Cooper Lighting

Cooper Lighting FAIL-SAFE FWS User manual

Cooper Lighting Sure-Lites LPX Series User manual

Cooper Lighting

Cooper Lighting Sure-Lites LPX Series User manual

Cooper Lighting Metalux 2GCAML User manual

Cooper Lighting

Cooper Lighting Metalux 2GCAML User manual

Cooper Lighting Metalux 471 User manual

Cooper Lighting

Cooper Lighting Metalux 471 User manual

Cooper Lighting 698 Series User manual

Cooper Lighting

Cooper Lighting 698 Series User manual

Cooper Lighting MCGRAW-EDISON CAA User manual

Cooper Lighting

Cooper Lighting MCGRAW-EDISON CAA User manual

Cooper Lighting Metalux 410 User manual

Cooper Lighting

Cooper Lighting Metalux 410 User manual

Cooper Lighting Fail-Safe FWS User manual

Cooper Lighting

Cooper Lighting Fail-Safe FWS User manual

Cooper Lighting INVUE IMI-567 User manual

Cooper Lighting

Cooper Lighting INVUE IMI-567 User manual

Cooper Lighting Shaper 687-WP Series User manual

Cooper Lighting

Cooper Lighting Shaper 687-WP Series User manual

Popular Indoor Furnishing manuals by other brands

Whalen BBAVT27-MBC manual

Whalen

Whalen BBAVT27-MBC manual

for Living Lakeville H13-1076 Assembly instructions

for Living

for Living Lakeville H13-1076 Assembly instructions

Office Star Products Work Smart FC8482-2 operating instructions

Office Star Products

Office Star Products Work Smart FC8482-2 operating instructions

Trasman 1770 Jazz Assembly manual

Trasman

Trasman 1770 Jazz Assembly manual

VASAGLE XHSR22 Instruction

VASAGLE

VASAGLE XHSR22 Instruction

OSP Designs 101 operating instructions

OSP Designs

OSP Designs 101 operating instructions

Kanto AVT Series user manual

Kanto

Kanto AVT Series user manual

MARCKERIC 15006 Assembly instructions

MARCKERIC

MARCKERIC 15006 Assembly instructions

modway EEI-3404 manual

modway

modway EEI-3404 manual

Household Essentials 8116-1 instructions

Household Essentials

Household Essentials 8116-1 instructions

OSP Designs MET2230 Assembly instructions

OSP Designs

OSP Designs MET2230 Assembly instructions

Livarno Living 114768 Assembly instruction

Livarno Living

Livarno Living 114768 Assembly instruction

Birlea CORONA 2 DOOR 5 DRW SIDEBOARD Assembly instructions

Birlea

Birlea CORONA 2 DOOR 5 DRW SIDEBOARD Assembly instructions

IKEA BUSSAN manual

IKEA

IKEA BUSSAN manual

AOKE AK2YJRT-ZF3 user manual

AOKE

AOKE AK2YJRT-ZF3 user manual

Fleurco MC03 installation manual

Fleurco

Fleurco MC03 installation manual

Bell'O OD10205-48-WHT Assembly instructions

Bell'O

Bell'O OD10205-48-WHT Assembly instructions

PURPLE LEAF ZY05PRG1117-733A Assembly manual

PURPLE LEAF

PURPLE LEAF ZY05PRG1117-733A Assembly manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.