manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cooper Lighting
  6. •
  7. Light Fixture
  8. •
  9. Cooper Lighting METALUX 2AC 232T8 User manual

Cooper Lighting METALUX 2AC 232T8 User manual

Other Cooper Lighting Light Fixture manuals

Cooper Lighting LINEA LV800P User manual

Cooper Lighting

Cooper Lighting LINEA LV800P User manual

Cooper Lighting HALO H2570 User manual

Cooper Lighting

Cooper Lighting HALO H2570 User manual

Cooper Lighting Sure Lites AEL1SD User manual

Cooper Lighting

Cooper Lighting Sure Lites AEL1SD User manual

Cooper Lighting Quiet Ceiling Series QCT-1975BK User manual

Cooper Lighting

Cooper Lighting Quiet Ceiling Series QCT-1975BK User manual

Cooper Lighting AMETRIX Cove User manual

Cooper Lighting

Cooper Lighting AMETRIX Cove User manual

Cooper Lighting Metalux WS Series User manual

Cooper Lighting

Cooper Lighting Metalux WS Series User manual

Cooper Lighting Combolight MLU313 User manual

Cooper Lighting

Cooper Lighting Combolight MLU313 User manual

Cooper Lighting Metalux T5 User manual

Cooper Lighting

Cooper Lighting Metalux T5 User manual

Cooper Lighting Ametrix Wall/Ceiling Lighting User manual

Cooper Lighting

Cooper Lighting Ametrix Wall/Ceiling Lighting User manual

Cooper Lighting Halo Cascade I H2574 User manual

Cooper Lighting

Cooper Lighting Halo Cascade I H2574 User manual

Cooper Lighting METALUX 214T5 User manual

Cooper Lighting

Cooper Lighting METALUX 214T5 User manual

Cooper Lighting COMBOLIGHT LV3060IS User manual

Cooper Lighting

Cooper Lighting COMBOLIGHT LV3060IS User manual

Cooper Lighting Exterior Wall Luminaire 694-WP-RB User manual

Cooper Lighting

Cooper Lighting Exterior Wall Luminaire 694-WP-RB User manual

Cooper Lighting HALO L1702 User manual

Cooper Lighting

Cooper Lighting HALO L1702 User manual

Cooper Lighting METALUX SM-ASY User manual

Cooper Lighting

Cooper Lighting METALUX SM-ASY User manual

Cooper Lighting Metalux 132T8 User manual

Cooper Lighting

Cooper Lighting Metalux 132T8 User manual

Cooper Lighting T4 E11 User manual

Cooper Lighting

Cooper Lighting T4 E11 User manual

Cooper Lighting Quiet Ceiling Series QCT-1876-SH-BK User manual

Cooper Lighting

Cooper Lighting Quiet Ceiling Series QCT-1876-SH-BK User manual

Cooper Lighting Combolight LV470 User manual

Cooper Lighting

Cooper Lighting Combolight LV470 User manual

Cooper Lighting Halo L5063870 User manual

Cooper Lighting

Cooper Lighting Halo L5063870 User manual

Cooper Lighting LUMARK M4 User manual

Cooper Lighting

Cooper Lighting LUMARK M4 User manual

Cooper Lighting G Series User manual

Cooper Lighting

Cooper Lighting G Series User manual

Cooper Lighting Halo H1BSMLRG User manual

Cooper Lighting

Cooper Lighting Halo H1BSMLRG User manual

Cooper Lighting AMETRIX SRR User manual

Cooper Lighting

Cooper Lighting AMETRIX SRR User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

ArtFox Beam 15R extreme manual

ArtFox

ArtFox Beam 15R extreme manual

GLG multispot 330 user manual

GLG

GLG multispot 330 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
08/26/2008 2:48:16 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF080359
MOUNTING DATA
LAMP CONFIGURATIONS
CEILING COMPATIBILITY
DESCRIPTION
The accord(TM) redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accord(TM) provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, accord(TM) increases the comfort level while providing
significant energy savings.
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and
other applications.
A ... Construction
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end
plates are securely attached with
screws for strength and rigidity
and the elimination of gaps. Four
auxiliary fixture end suspension
points are provided. KOs for
continuous row wiring. Large
access plate for supply connection.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
C ... Ballast Access
Ballast can be removed from
below without tools.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
E ... Reflectors
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
F ... Shielding
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
G ... Air Return
Optional Air Return model
provides air flow through air slots
in the housing.
2AC
232T8
T8 LAMPS
2' x 4' Recessed
Troffer Series
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
23-3/4"
[603 mm]
3-1/4"
[83mm]
AB C D FE
48" [1219mm]
8" [204mm]
Access Plate
23-3/4"
[603mm]
4-13/16" [123mm]
1-1/2" [204mm]
23-3/4" [603mm]
3-1/4"
[83mm]
11-3/4" [298mm]
G
Grid/Lay-in
Standard
F
Drywall Frame
Kit
Ceiling Trim
Type** Type
Exposed Grid G
ConcealedT G orT
Slot Grid G orT
Flange ***
EB Ballast & STD Lamps @ 277V
232 (58)
Luminaire Efficacy Rating
LER =FL80 LPW
Catalog Number: 2AC-232
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $2.90
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
E N E R G Y D ATA
Input Watts:
COOPER LIGHTING - METALUX®
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 08/26/2008 2:48:16 PM
Specifications and Dimensions subject to change without notice.
ADF080359
PHOTOMETRICS
ORDERING INFORMATION
SHIPPING INFORMATION
2AC
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Luminance Data
Average Average Average
Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm
45 2186 2425 2628
55 2115 2513 2830
65 1996 2651 2902
75 1743 2524 2574
85 1331 1939 1857
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candlepower
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2AC-232-UNV-EB81
Electronic Ballast
(2) F32T8/835 Lamps
3100 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 84.9%
Test Report:
2AC-232-UNV-
EB81.IES
LER = FL80 LPW
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.90
1613 1613 1613
1605 1610 1616
1585 1594 1604
1550 1568 1585
1501 1530 1557
1439 1482 1520
1365 1424 1476
1279 1357 1424
1183 1281 1365
1079 1197 1297
966 1106 1220
847 1006 1133
722 898 1021
589 782 856
452 634 663
315 456 465
187 280 277
81 118 113
0 0 0
101 101 101 101 99 99 99 99 94 94 94 90 90 90 87 87 87 85
92 87 83 80 89 85 82 79 82 79 76 78 76 74 75 73 72 70
83 75 69 64 81 74 68 63 71 66 62 68 64 60 65 62 59 57
75 66 58 53 73 64 57 52 62 56 51 59 54 50 57 53 49 47
69 58 50 44 66 57 49 44 54 48 43 52 47 42 51 46 42 40
63 51 43 38 61 50 43 37 49 42 37 47 41 36 45 40 36 34
58 46 38 33 56 45 38 32 44 37 32 42 36 32 41 36 31 30
54 42 34 29 52 41 34 28 40 33 28 38 32 28 37 32 28 26
50 38 30 25 48 37 30 25 36 30 25 35 29 25 34 29 25 23
46 35 28 23 45 34 27 23 33 27 22 32 26 22 31 26 22 21
44 32 25 20 42 32 25 20 31 25 20 30 24 20 29 24 20 19
1279 20.6 24.3
2127 34.3 40.4
3942 63.6 74.9
5266 84.9 100.0
5266 84.9 100.0
SAMPLE NUMBER: 2AC-232-UNV-L8841-EB82-U
Voltage(1)
UNV=Universal
Voltage 120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
Shielding
Blank=Frosted Acrylic
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
NOTES: (1) Products also available in non-US voltages and frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice.
Consult your Cooper Lighting Representative for availability and ordering information.
Lamps
L8835=T8 Lamp, 17W
and 32W, 3500K
L8841=T8 Lamp, 17W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
BallastType
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.Total
Harmonic Distortion < 20%
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
HPT8 Ballast
Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
No. of Ballast
1 or 2
No. of
Ballast
1 or 2
No. of Ballast
1 or 2
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
32=32WT8 (48")
Series
AC=Accord Series
Width
2=2' Width
Rating
Blank=
Standard
NY=NewYork
Rated
ATW-SW4=
Chicago
Rated
Type
A=Air (optional)
=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8_DI M
.sbl82232-CA2
Catalog No. Wt.