STANDARD OPEN FIXTURE INSTALLATION
1. Unscrew two screws from cover plate or cone located at xture base. (FIG. 2) Remove plate or cone cover
to gain access to the wiring compartment.
2. Pull electrical service leads through the pole with sufcient length to reach through and into the wiring
compartment of the xture. The service leads should pass through the large, circular openings in the
mounting plate to avoid cutting or pinching the leads.
3. Connect service leads to the appropriate position with the terminal block. (FIG. 3)
a. Three-terminal block (2-wire service): Connect line service lead to terminal that is connected to black
factory-installed wire. Connect neutral service wire to terminal that is connected to white factory-installed
wire.
b. Three-terminal block (3-wire service, 2 lines, 1 ground): Connect 1 line service lead to terminal that is
connected to black factory-installed wire. Connect other line service lead to terminal that is connected to
white factory-installed wire. Connect ground service lead to terminal that is connected to green
factory-installed wire.
c. Three-terminal block (3-wire service, 1 line, 1 neutral, 1 ground): Connect line service lead to terminal
that is connected to black factory-installed wire. Connect neutral service wire to terminal that is connected
to white factory-installed wire. Connect ground service wire to terminal that is connected to green
factory-installed wire.
d. No terminal block (3-wire service, 2 lines, 1 ground): Connect 1 line service lead to black
factory-installed wire. Connect other line service lead to white factory-installed wire. Connect ground
service lead to green factory-installed wire.
e. No terminal block (3-wire service, 1 line, 1 neutral, 1 ground): Connect line service lead to black
factory-installed wire. Connect neutral service wire to white factory-installed wire. Connect ground service
wire green factory-installed wire.
4. For xtures with asymmetric light patterns, locate the word “streetside” on the overhang plate and rotate
the xture on the pole such that the word “streetside” is facing the street.
5. Secure the xture to the pole top by tightening the three square head bolt in the xture base.
Recommended tightening torque: 120-140 in-lbs.
6. Reattach plate or cone cover to xture base and secure with two cover retaining screws.
7. The xture is now ready to energize.
STANDARD FIXTURE WITH LENS INSTALLATION
1. Loosen the captive cover retaining screws or spring latches and open the hinged top cover of the xture.
(FIG. 1)
2. Remove two nuts and screw on LED assembly (FIG. 4) and lift LED assembly to side.
3. Remove two acrylic refractor panels by lifting them up and out of the slotted corner posts.
4. Unscrew two screws from cover plate at xture base. (FIG. 2) Remove plate cover to gain access to the
wiring compartment.
5. Pull electrical service leads through the pole with sufcient length to reach through and into the wiring
compartment of the xture. The service leads should pass through the large, circular openings in the
mounting plate to avoid cutting or pinching the leads.
ADH121960
— continued
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
P: 770.486.4800 F: 770.486.4801
www.cooperlighting.com
TraditionaireTM LED
Decorative Luminaire
Sheet 1 of 2
1/7/2013 IMI-780
SAFETY: This xture must be wired in accordance with the National Electrical Code
and applicable local codes and ordinances. Proper grounding is required to insure
personal safety. Carefully observe grounding procedure under installation section.
WARNING: Make certain power is OFF before starting installation or attempting any
maintenance. Risk of re/electric shock. If not qualied, consult an electrician.
• RISK OF ELECTRIC SHOCK—Disconnect power at fuse or circuit breaker before
installing or servicing.
• RISK OF BURN—Disconnect power and allow xture to cool before servicing.
• RISK OF PERSONAL INJURY— Fixture may become damaged and/or unstable if
not installed properly. Tighten all xture components to their recommended torque
values. Do not lift pole into place by securing lifting device to lighting xture.
INSTALLATION INSTRUCTIONS
IMPORTANT: READ BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
WARNING: Make certain power is OFF before starting installation or attempting any maintenance.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufciently for user’s purpose, please contact
your nearest representative. NOTE: Specications and dimensions subject to change without notice.
Cupula Cover
Cupula Housing
Cone or Plate Cover
Captive Cover
Retaining Screws (2)
or Spring Latches (2)
Wiring Compartment
Fixture Base
FIG. 1
Cone or Plate
Cover Screws (2)
FIG. 2
Terminal Block (L1)
Terminal Block (N)
Terminal Block (L2)
FIG. 3
6. Connect service leads to the appropriate position with the terminal block. (FIG. 3)
a. Three-terminal block (2-wire service): Connect line service lead to terminal that is connected to black
factory-installed wire. Connect neutral service wire to terminal that is connected to white factory-installed
wire.
b. Three-terminal block (3-wire service, 2 lines, 1 ground): Connect 1 line service lead to terminal that is
connected to black factory-installed wire. Connect other line service lead to terminal that is connected to
white factory-installed wire. Connect ground service lead to terminal that is connected to green
factory-installed wire.
c. Three-terminal block (3-wire service, 1 line, 1 neutral, 1 ground): Connect line service lead to terminal
that is connected to black factory-installed wire. Connect neutral service wire to terminal that is connected
to white factory-installed wire. Connect ground service wire to terminal that is connected to green
factory-installed wire.
d. No terminal block (3-wire service, 2 lines, 1 ground): Connect 1 line service lead to black
factory-installed wire. Connect other line service lead to white factory-installed wire. Connect ground
service lead to green factory-installed wire.
e. No terminal block (3-wire service, 1 line, 1 neutral, 1 ground): Connect line service lead to black
factory-installed wire. Connect neutral service wire to white factory-installed wire. Connect ground service
wire green factory-installed wire.
7. For xtures with asymmetric light patterns, locate the word “streetside” on the overhang plate and rotate
the xture on the pole such that the word “streetside”
is facing the street.
8. Secure the xture to the pole top by tightening the three square head bolt in the xture base.
Recommended tightening torque: 120-140 in-lbs.
9. Reattach plate or cone cover to xture base and secure with two cover retaining screws.
10. Replace the two previous acrylic refractors panels.
11. Reattach LED assembly to xture with previous screws and nuts. Close the cover and secure with
two cover retaining screws or secure spring latches.
12. Secure the xture to the pole top by tightening the three square head bolt in the xture base.
Recommended tightening torque: 120-140 in-lbs.
13. The xture is now ready to energize.
STANDARD OPEN FIXTURE INSTALLATION
When specied, the Traditionaire xture is furnished with a rotatable photocontrol receptacle that allows
the photocontrol to be properly positioned with the use of a straight blade screwdriver.
1. Lift off cupola roof. (FIG. 1)
2. Remove the shorting cap (when furnished) and loosen the two at head screws.
3. Rotate the cupola until the window in the cupola is facing in a northerly direction. Line up the north
arrow of the photocontrol receptacle with the window in the cupola. Retighten the screws and install
the photocontrol. (FIG. 5)
4. Replace the cupola roof.
CAUTION: THE RECEPTACLE HAS A BUILT-IN STOP WHICH ALLOWS 350° ROTATION. DO NOT ATTEMPT TO
ROTATE BEYOND THIS STOP AS YOU WILL DAMAGE THE RECEPTACLE.
ADH121960
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
P: 770.486.4800 F: 770.486.4801
www.cooperlighting.com
TraditionaireTM LED
Decorative Luminaire
Sheet 2 of 2
1/7/2013 IMI-780
INSTALLATION INSTRUCTIONS
IMPORTANT: READ BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
WARNING: Make certain power is OFF before starting installation or attempting any maintenance.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufciently for user’s purpose, please contact
your nearest representative. NOTE: Specications and dimensions subject to change without notice.
LED Assembly
Acrylic Refractor (4)
Nut and Screw Set (2)
Cone or Plate Cover
FIG. 4
Cupola Window
to Face North
FIG. 5

Other Cooper Lighting Outdoor Light manuals

Cooper Lighting ALL-PRO FE0650LPC User manual

Cooper Lighting

Cooper Lighting ALL-PRO FE0650LPC User manual

Cooper Lighting MS180 User manual

Cooper Lighting

Cooper Lighting MS180 User manual

Cooper Lighting ALL-PRO AL2550LPCBZ User manual

Cooper Lighting

Cooper Lighting ALL-PRO AL2550LPCBZ User manual

Cooper Lighting HALO FSS153TIB User manual

Cooper Lighting

Cooper Lighting HALO FSS153TIB User manual

Cooper Lighting Lumark Crosstour MAXX User manual

Cooper Lighting

Cooper Lighting Lumark Crosstour MAXX User manual

Cooper Lighting Halo SWL0540W User manual

Cooper Lighting

Cooper Lighting Halo SWL0540W User manual

Cooper Lighting Arbor Post Top User manual

Cooper Lighting

Cooper Lighting Arbor Post Top User manual

Cooper Lighting ALL-PRO AL2050LPCBZ User manual

Cooper Lighting

Cooper Lighting ALL-PRO AL2050LPCBZ User manual

Cooper Lighting HALO HOME FTS20CW User manual

Cooper Lighting

Cooper Lighting HALO HOME FTS20CW User manual

Cooper Lighting All-Pro FES0650LPCW User manual

Cooper Lighting

Cooper Lighting All-Pro FES0650LPCW User manual

Cooper Lighting FE13PC Series User manual

Cooper Lighting

Cooper Lighting FE13PC Series User manual

Cooper Lighting ALL-PRO FES0650LPC User manual

Cooper Lighting

Cooper Lighting ALL-PRO FES0650LPC User manual

Cooper Lighting PWT250PC User manual

Cooper Lighting

Cooper Lighting PWT250PC User manual

Cooper Lighting Streetworks Valet LED User manual

Cooper Lighting

Cooper Lighting Streetworks Valet LED User manual

Cooper Lighting Streetworks TRU Tribute User manual

Cooper Lighting

Cooper Lighting Streetworks TRU Tribute User manual

Cooper Lighting StreetWorks SDL User manual

Cooper Lighting

Cooper Lighting StreetWorks SDL User manual

Cooper Lighting MSL180 User manual

Cooper Lighting

Cooper Lighting MSL180 User manual

Cooper Lighting HALO AL4850LPC Series User manual

Cooper Lighting

Cooper Lighting HALO AL4850LPC Series User manual

Cooper Lighting PQS600R User manual

Cooper Lighting

Cooper Lighting PQS600R User manual

Popular Outdoor Light manuals by other brands

Gainsborough Solar Lying Angel Assembly instructions/Instructions for use

Gainsborough

Gainsborough Solar Lying Angel Assembly instructions/Instructions for use

BEGA 84 061 Installation and technical information

BEGA

BEGA 84 061 Installation and technical information

LED's light OUTDOOR Series installation instructions

LED's light

LED's light OUTDOOR Series installation instructions

Quoizel ALM8406WT installation guide

Quoizel

Quoizel ALM8406WT installation guide

Winsome house Pagoda Solar WH082 instruction manual

Winsome house

Winsome house Pagoda Solar WH082 instruction manual

Inspire MIRASOL YF4246 instruction manual

Inspire

Inspire MIRASOL YF4246 instruction manual

DS Produkte CR-4040C operating instructions

DS Produkte

DS Produkte CR-4040C operating instructions

Pro-Elec PEL01352 manual

Pro-Elec

Pro-Elec PEL01352 manual

Adesso ZODIAC Assembly instruction

Adesso

Adesso ZODIAC Assembly instruction

IMMAX 08490L quick start guide

IMMAX

IMMAX 08490L quick start guide

LIGMAN FORREY 4 FOR-10092 installation manual

LIGMAN

LIGMAN FORREY 4 FOR-10092 installation manual

WAC Lighting dweLED 139 Series installation instructions

WAC Lighting

WAC Lighting dweLED 139 Series installation instructions

Safavieh Furniture FLL4016A manual

Safavieh Furniture

Safavieh Furniture FLL4016A manual

Targetti ZEDGE BOLLARD manual

Targetti

Targetti ZEDGE BOLLARD manual

LIGMAN LD-50021 installation manual

LIGMAN

LIGMAN LD-50021 installation manual

Nemo Studio LUX 09 g.2 Mounting instructions

Nemo Studio

Nemo Studio LUX 09 g.2 Mounting instructions

Quoizel MRL9009SU installation guide

Quoizel

Quoizel MRL9009SU installation guide

Vista Landscape Series installation instructions

Vista

Vista Landscape Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.