COPAL ELECTRONICS PG-35L User manual

①ThetypeofpressuremediaforPG-35Lshouldbeusedliquidandgasthatdon'tcorrodeforSUS316L.
②Forstability,usearegulateddirectcurrentpowersupply.
Surgeabsorbingdevices(diodes,varistors,etc.)arenecessaryifinductiveloadssuchasrelaysorsolenoidsareconnectedtothesame
circuitasthePG-35L.
IfusingaDCpowersupplyunitsuchasaswitchingpowersupply,theFGterminalshouldbeearthed.Donotwireinparalleltohigh
tensioncablesorpowerlines,orusecableductswhichcontainhightensioncablesorpowerlines.
③Becarefulnottocrimpanywiresduringhandling,orputanypressureonthedisplayareaofthemainbodywhileassemblingpiping.
④UsepHneutraldetergentstocleanthebody.Donotusesolventssuchasthinners.
⑤Thisproductisdustproofanddripproof(IP65ofIECstandards)andisnotsuitableforuseinenvironmentsrequiringhigherstandards.
Also,donotusethisproductinanenvironmentwithapossibilityofproductbeingcoveredbyliquidsotherthenwater(Suchasoil,
solvent,andetc.)andoutdoor.
⑥Donotusepointedobjectssuchaspenstopressthesettingbuttonsonthe displaypanel,asthismaypushholesinthesetting
buttonsanddamagethem.
⑦Do not insert wires, etc. in the pressure port, as this may damage the
internaldiaphragmandcausemalfunctioning.
⑧gaskettype:
Do not touch or scratch the edge of the fitting, as this may damage the
sealingandcauseleakage.
⑨ThePG-35Ldonothaveanexplosionproofstructure.Donotuseitforthe
detectionofflammablegases.
⑩Whenanalogoutputissuppliedtoanoise-sensitivedevice,alow-passfilter
isrequestedinacustomer'scircuit.
⑪Countermeasuresfornoiseinterference:
Please connect either the shield wire or the metal part of the product to
frameground(FG)ofthepowersource.
⑫Incaseawireextensionisneeded,pleaseuseashieldedwire.
Thankyouforpurchasinga
NIDECCOPALELECTRONICSCORP.product.
Inordertousetheproductcorrectlyandmostappropriately,
pleasecompletelyreadthismanualbeforeuseandkeepit
forfuturereference.
INSTRUCTION MANUALVer.1.1
ImportantInformationandWarnings
Nishi-ShinjukuKimurayaBidg.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,JapanPhone.:(03)3364-7055
Formoredetailedinformationpleaseaskforthenearestdistributororthefollowingsalescenter.
PG-35L
CEmarking
(CompliancewithEMCStandard)
HIGH VACUUM CORRESPONDENCE
SMALL SIZE PRESSURE GAUGE
Powersupplyunit
Surgeabsorbingcircuit +V
FG←Theshieldwire
PG35L
FG
DCoutputACinput

1
Specifications
Input/OutputCircuitDiagrams(WireColorsConformtoIECStandards)
NPNOpenCollectorOutputModel PNPOpenCollectorOutputModel
Model
Type
Ratedpressurerange
Maximumpressure
Break-downpressure
Acceptablemedia
Operatingvoltage
Currentconsumption
Switch
outputs
Outputmode
Outputmode
Analogoutput
Hysteresis
Repeatability
Response
Shortcircuitprotection
Gaugepressure
LiquidsorgasesthatdonotcorrodeSUS316L
Pressurerange Pin(L)〜Pin(H)
1±0.2V
4±0.2V
Outputvoltageaccuracy Vzero(upper)/Vspan(Lower)
(Vzero:Pin=0、Vspan:Pin=0〜Pin(H))
-100〜100kPa
0〜100kPa
0〜-100kPa
3±0.2V
2±0.2V
1±0.2V
4±0.2V
R
G
V
R
G
V
-100〜1000kPa
0〜1000kPa
1.36±0.2V
3.64±0.2V
10.8〜30VDC(includingripple)
50
mAmaximum
0〜300countssetting(adjustable)
±0.2%FS±1digit
Approx.5ms(DigitalFillter:F-0)
Exists
Outputvoltage1〜5V/Pin(L)〜Pin(H),Outputimpedance:10kΩ,Resolution:1/204
OnlyR/Gmodeisavailableon103R.
-100〜100kPa
200kPa
300kPa
-100〜1000kPa
1500kPa
2000kPa
PG-35L
102R 103R
TwooutputsNPN/PNP:Transistoropencollector
Switchrating:30VDC100mAmaximum
Residualvoltage:1.2Vmaximum(NPN)/2.2Vmaximum(PNP)at100mA.
Display
Operationdisplay
Operating
conditions
Thermalerror
Fittingparttypes
Materialsatpressurereceivingarea
NetWeight
Accessories
Negativepressuredisplay
Displayaccuracy
IPprotection
Operatingtemperature
Operatinghumidity
Insulationresistance
Dielectricstrength
Vibrationresistance
Shockresistance
EMC
Full3digitLEDdisplay(displaycycle:4timespersecond)
−LEDislit
±1%FS
SW1LED(green)andSW2LED(red)lightupwhenswitchoutputsareON
MeetsIP65(pressuregaugemainbody)ofIEC
−10〜50℃(storage−20〜70℃)
35〜85%RH
50MΩminimumatDC125Vbetweenbundledleadsandpressureport
OneminuteatDC125Vbetweenbundledleadsandpressureport(1mAmaximumleakage)
10〜500HZ1.5mmmaximum/
98.1
m
/
S
2
,threedirections,twohourseach
490m/s,threedirections,threetimeseach
SUS316L
150±30g(incl.2mcable)
O-ring(G1/4:P15)
R1/4,G1/4,
gasketfitting9/16-18UNF
±3%FS(0〜50℃)
Encloseliquid
Usablepressureinvacuum
Nonexistence
Above1.4×10-4Paabs
EMI:EN5501Group1,ClassB/1998
EMS:EN61326-1/1997:Thepermissiblechangeofdisplaycounts,setvalueofswitchoutput
andzero/spanvoltageofanalogoutputduringthetestnotexceed
±5%FS.
±
(brown)
(gray)
(black)
Switchoutput1
(white)Switchoutput2
(blue)
Powersupply
D.C10.8〜30V
SensorSensor
Display
LED
Sensor
Sensor
Sensor
Display
LED Powersupply
D.C10.8〜30V
COM COM
Shield
Analog
output
(brown)
(black)
Switchoutput1
(white)
Switchoutput2
(gray)
(blue)
Analog
output
loadload
load load
Shield FGterminal
FGterminal

OperatingProcedures
InitialSettingsMode
2
FunctionNames
Setmagnification
(elevenselections)
Setanalogoutput
(threeselections)
Setswitchoutput
(eightcombinations)
Initial
Settings
Mode
Setting1
Setting2
Hysteresis
(0〜300digits)
DigitalFilter
(F-0〜F-3)
Pressthe and
buttons
simultaneously
Pressthe button
(morethanone
second)
Pressthe and
buttons
simultaneously
Pressthe button
(morethanone
second)
kPa
+/− SW1 SW2
COPAL ELECTRONICS
Pressthe and buttons
simultaneouslytoenterthe
InitialSettingsMode.
Note:Values forthe102R,
forthe103Raresetprior
todelivery.
Pressthe buttontomove
Pressthe buttonfor
morethanonesecond
toreturntothe
OperationsMode.
Pressthe buttontomove
tothenextdigit.Thevalue
ofthedigitmaybesetwhen
theLEDbelowthedigitflashes.
TheLEDofanitemflasheswhen
selectedusingthe button.
Usethe and buttontoset
thevalueofeachdigit.
Third
digit
Multiplierfactor
Analogoutput Switchoutput
1:Rmode
2:Gmode
3:Vmode
1〜4:SeparateMode
5〜8:WindowComparatorMode
First
digit
Second
digit
Operations
Mode
Pressure
Settings
Mode
1:×1
2:×0.0102
3:×10.2
4:×7.501
5:×102
6:×0.01
7:×10
8:×0.145
9:×0.000145
A:×0.001
b:×0.2953
kPa
+/− SW1 SW2
COPAL ELECTRONICS
−LED(red) Full3digitLED
SW1LED(green)
SW2LED(red)
Displayunit
Upbutton
Downbutton
Modebutton
Whenthepowerisswichedon,theOperationsModeisautomaticallyselected.Settingsremainineffectafterswitchingoffthepower.
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
+/− SW1 SW2
COPAL ELECTRONICS

3
MultiplierfactorSetting
AnalogOutputSetting
SwitchOutputSetting
Note:1issetpriortodelivery.
Pressthe
buttonuntil
the−LEDunderthe
thirddigitflashes.
Setthevalueofthethird
digitto4using
and
buttons.
Pressthe buttonformore
thanonesecondtoreturn
totheOperationsMode.
Anexampleofsetting4.
※Changeofmagnificationsettingiseffectiveonlyforpressurereading.Setvaluesforswitchingarenotscaledautomatically.
Themultiplierfactorsettingisdeterminedbythevalueofthethirddigit:thered−LEDshouldbeflashingduringthesetting.
Theanalogoutputsettingisdeterminedbythevalueoftheseconddigit:thegreenSW1LEDshouldbeflashingduringthesetting.
Theswitchoutputsettingisdeterminedbythevalueofthefirstdigit:
theredSW2LEDshouldbeflashingduringthesetting.
Therearefouroperationmodes.Theseareshowninthediagramsbelow.
Note1.IntheSeparateMode,setting1correspondstoSW1,andSetting2correspondstoSW2.
Note2.IntheWindowComparatorMode,theminimumvalueforSW1andSW2correspondstoSetting1andthe
maximumvaluecorrespondstoSetting2.
Valueselected
Valueselected
Valueselected
Pressurerange(-Pr〜+Pr)
Muitiplierfactor 102R 103R
1
2
3
Rmode(Compoundpressureoutput)
Gmode(Positivepressureoutput)
Vmode(Negativepressureoutput)
Mode −Pr 0 +Pr
(Vzero)
1V
1V
1V
5V
5V
5V
Sectionscontaininganobliquestrokearemultiplierfactorthatcannotbeselectedbecauseofresolvingpowerordisplaydigits.
(Valueswillnotbedisplayedautomatically.)
IntheOperationsMode,pressthe
and buttonssimultaneouslyto
entertheInitialSettingsMode.
Pressthe buttonuntilthe
SW1LEDunderthesecond
digitflashes.
Setthevalueofthesecond
digitto1usingthe and
buttons.
AnexampleofsettingtheRmodeinthe102Rrange.
Notes:Vmodefor102Raresetpriortoshipment.R/Gmodefor103Rcanonlybeselected.
kPa
+/− SW1 SW2
COPAL ELECTRONICS
Intheoperationsmode,
pressthe and
buttonssimultaneously
toentertheInitial
SettingsMode.
Pressthe button
untiltheSW2LED
underthefirstdigit
flashes.
Setthevalueofthe
firstdigitto7
usingthe
and buttons.
Pressthe button
formorethanone
secondtoreturnto
theOperationsMode.
Output
Mode
Operation
1
2
3
4
5
6
7
8
SW1output
Separate
H
○
○
L
○
○
A
○
○
B
○
○
H
○
○
L
○
○
A
○
○
B
○
○
Windowcomparator
Note1
Setting1
Note2
Minimum:Setting1
Maximum:Setting2 Minimum:Setting1
Maximum:Setting2
Note1
Setting2
Note2
Separate
Windowcomparator
SW2output
kPa
+/− SW1 SW2
COPAL ELECTRONICS
■WindowComparatorMode
(Anexampleofsettingthevalue7
forthemodeshowninthediagram.)
ON
ON
OFF
OFF
SW1
SW2
Setting
value1 Setting
value2
Hysteresis Hysteresis
SeparateMode WindowComparatorMode
Intheoperationsmode,press
the
and
buttonssimultaneously
toentertheInitialSettingsMode.
Pressthe buttonformore
thanonesecondtoreturnto
theOperationsMode.
Low High
(Hoperation)
OFF
ON
-Pr Pr
HH
P1:SW1 P2:SW2
ON
OFF
-Pr Pr
HH
P1:SW1 P2:SW2
(Loperation)
(Aoperation)
OFF
ON ON
-Pr Pr
HH
P1 P2
P1 P2
(Boperation)
OFF OFF
ON
-Pr Pr
HH
1
2
3
4
5
6
7
8
9
A
b
-99.9〜99.9
-999〜999
-750〜750
-999〜999
-14.5〜14.5
-29.5〜29.5
-100〜999
-1.02〜9.99
-1.00〜9.99
-14〜145
-0.10〜1.00
-29〜295
×1
×0.0102
×10.2
×7.501
×102
×0.01
×10
×0.145
×0.000145
×0.001
×0.2953
P1≦P2 or P1≧P2 P1≦P2−2H
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS

4
PressureSettingsMode
Troubleshooting
+/− SW1 SW2
Pressthe
and buttons
simultaneouslytoenter
thePressureSettingsMode.
(TheSW1LEDflashes.)
TheLEDofanitemflashes
whenselectedusingthebutton.
Pressthe buttontoselect
betweenswitchoutput1setting
(SW1),switchoutput2setting
(SW2),orthehysteresissetting.
Setthevalue
usingthe
andbuttons.
Pressthe buttonfor
morethanonesecond
toreturntotheOperations
Mode.
■Ifthefollowingerrormessagesaredisplayed,followtheproceduresinthetable.
Displayandproblem Cause Solution
E
-
1
E
-
2
E
-
3,E
-
4
999 Flashing
Flashingofthepressurevalue
Blackoutofthedisplay
Disablethekeyoperation
Outputcurrentisexceeding100mA. Turnoffthepowerandverifytheload
connectedswitchoutput1and2.
PressMbuttonandreturntheappliedpressuretothe
atmosphericpressureandtryzero-pointadjustmentagain.
Pleasecontactus.PleaseusearegulatedDCpower
supplyandmeasuresforthepowerlinenoise.
Normalstate
Normalstate
Normalstate(SeeNon-displaymode.)
Normalstate(SeeKeyprotectionmode.)
Pressurewasappliedatthezeropoint
adjustment.
Failureoftheinternalcircuit.
Pressurevaluesexceedthedisplayrange.
Pressurevaluesexceedtheratedpressure
range.(110%FS)
Non-displaymode
Keyprotectionmode
Note:+50%F.S.issetpriortodelivery.
Anexampleofsetting60kPaforswitchoutput1(SW1LEDisflashing)with102R.
Tosetswitchoutput1theSW1LEDshouldbeflashing.(Tosetswitchoutput2theSW2LEDshouldbeflashing.)
Note:20digitsissetpriortodelivery.
Anexampleofsettingahysteresisvalueof8.0kPawiththe102R(kPa).
Hysteresissetting Switchoutput2
setting
Switchoutput1
setting
Tosethysteresisthe−LEDshouldbeflashing.
TosetDigitalFilterallLEDshouldbenotflashing.Anexampleofsetting2.5sresponsetimebyDigitalFilter.
Pressthebuttonuntil
theSW1LEDflashes.
Setthevalueto60.0
usingthe and
buttons.
Pressthe buttonfor
morethanonesecond
toreturnto
theOperations
Mode.
Pressthe and buttons.
Pressthe buttonuntil
the−LEDflashes. Setthevalueto8.0
usingthe and
buttons.
Pressthe buttonfor
morethanonesecondto
returntotheOperations
Mode.
Note:F-0issetpriortodelivery.
Pressthe and buttons.
Pressthe buttonuntil
allLEDdonotflashe. SetthevaluetoF-3
usingthe and
buttons.
Pressthe buttonfor
morethanonesecondto
returntotheOperations
Mode.
F-0:ResponseTime=5ms
F-1:ResponseTime=25ms
F-2:ResponseTime=250ms
F-3:ResponseTime=2.5s
Digitalfiltersetting
+/− SW1 SW2
Pressthe and buttons
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
SwitchOutputSetting
Hysteresissetting
DigitalFiltersetting

5
Tubeatatmosphericpressureintake
Piping
Non-DisplayMode
ZeropointAdjustment
Others
Useawrenchonahexagonoffittingpart.Donotholdthemainbodywhentightening.
If there is any possibility that the sensor may become wet with oil or water, which may
enterthecasethroughtheairintake,connectasilicontube,orsimilar,totheintakeand
positiontheendofthetubeinasuitablysafeplace.Besurenottobendthetubeorblock
theendofthetube.
Exampleofatubewith
externaldiameterofφ4
andinternaldiameter
ofφ2.5
PressingtheandbuttonssimultaneouslyintheOperationsMode
displays onthescreen.Onesecondlaterthischangetothan
theandbuttonsarereleased.(Ifthepressureportisopenedtothe
atmosphere.)
<Non-Display[Temporary]Mode>
・When the keys are not operated for more than 10 seconds during Operation Mode,the system will automatically select Non-Display
[Temporary]Modeandthedisplaywillturnoff.
・DecimalpointLEDshowninthefigurebelowwillblinkduringNon-Display[Temporary]Mode.
・UsingtheEEPROM,thePG-35Lcanretainpresetvaluesevenifthepoweristurnedoff.
・Ifanerrormessageisdetected,thedisplaywillcomebackandshowtheerrormessage.
・YoucanchangeanyfunctionsduringNon-Display[Temporary]Mode.
・To enable Non-Display[Temporary]Mode,press key for more than 4 seconds. will be displayed and Non-Display
[Temporary]Modewillbeset.After10seconds,displaywillgooff.
・To disable Non-Display[Temporary]Mode,press key for more than 4 seconds. will be displayed and Non-Display
[Temporary]Modewillbecanceled.
(Howtoset)
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
Blink
kPa
+/− SW1 SW2
COPAL ELECTRONICS
<Non-Display[Full-time]Mode>
・InNon-Display[Full-time]Mode,thedisplaywillbeturnedoffandtheKeyswillbelocked.
・DecimalpointLEDshowninthefigurebelowwilllightupduringNon-Display[Full-time]Mode.
・UsingtheEEPROM,thePG-35Lcanretainthepresetvaluesevenifthepoweristurnedoff.
・Ifanerrormessageisdetected,thedisplaywillcomebackandshowtheerrormessage.
・YoucannotchangeanyfunctionsduringNon-Display[Full-time]Mode.
・ToenableNon-Display[Full-time]Mode,press keyformorethan4seconds. willbedisplayedandNon-Display[Full-time]
Modewillbeset.Displaywillturnoffinasecond.
・TodisableNon-Display[Full-time]Mode,press keyformorethan4seconds. willbedisplayedandNon-Display[Full-time]
Modewillbecanceled.
(Howtoset)
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
Lightup

6
OutlineDimensions(Unit:㎜)
KeyProtectionMode
■PG-35LOutlineDimensions
・ToenableKeyProtectionMode,press keyformorethan4seconds. willbedisplayedandthekeyswillbelocked.
・TodisableKeyProtectionMode,press keyformorethan4seconds. willbedisplayedandthekeyswillbeunlocked.
<KeyProtectionMode>
・KeyProtectionModeisusedtolockthefrontpanelkeyinordertopreventpresetvaluesfrombeingaccidentallychanged.
・UsingEEPROM,thePG-35Lcanretainthepresetvaluesevenifthepoweristurnedoff.
(Howtoset)
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
kPa
+/− SW1 SW2
COPAL ELECTRONICS
16
16
□30
(68.7)
(M5screwsincluded)
L=2000±100
COPALELECTRONICS
31.4
Fivecoreshildedcable
kPa
Airintake
2-M4 Depth5
R1/4(PT1/4)
10.5
(32)
G1/4(PF1/4)
(68.2)
(M5screwsincluded)
kPa
COPALELECTRONICS
9/16-18UNF
(71.2)
COPALELECTRONICS
kPa
Fittingpart:G2type Fittingpart:VCtype
Fittingpart:R2type 37

7
Brackets(Option)
ModelNumbers
■PG-35LHoldercoverset(soldseparately)
36 +0.5
0
36 +0.5
0
panelcutdimensions(Panelthickness:1〜3.6㎜)
(Note)Since this product contains small components,
pleasehandlethisproductcarefully.
Productcanbedamagedifanunwantedforceis
applied.
■Accessories(Soldseparately)
Productname
Modelno.
Description
Applicable
model
Holdercoverset
(forprotectionof
gaugesides)
Panelholdercover,
panelholder
ACPG-004
PG-30/35
PG-35L
Pressureranges
102:-100to100kPa
103:-100to1000kPa
Fittingparttypes
R2:R1/4(M5femalescrewsincluded)
G2:G1/4(M5femalescrewsincluded)
VC:Gasketfitting9/16-18UNF
Modelname
PG-35L:Highcorrosionresistanceoillesstype Switchoutputtype
N:NPNopencollector
P:PNPopencollector
Pressurereference
R:Compoundpressure(negativepressure〜positivepressure)
PG−35L−102R−NR2
□40
(□42.6)
COPALELECTRONICS
kPa
Mainbody
Panelholder
Panelholdercover
Holder
coverset
24.7
4.5
(5.7)
This manual suits for next models
2