RUSH NT
INSTALLATION GUIDE-RECESSED
4 Option 2
CORONET, Inc.
55 Shepherds Lane
Totowa, NJ 07512
T 973 345 7660
F 973 345 8705
CORONET, Inc. reserves the right to make any design changes for continuous improvement which will not
affect the overall appearance or performance. All fixtures to be wired by a certified electrician only. WWW.CORONETLED.COM 2/2
!Risk of fire and electrical shock. In accordance with national local building and electrical codes, CORONET lighting fixtures must
be installed by a qualified electrician. Disconnect power at electrical panel before servicing.
56
7 Continuous Rows 8
Install the fixture by screwing through the flange into the ceiling. After screwing
the fixture into the ceiling, anchor the flange of the fixture properly (hardware by
others).
Spackle up to the side of the fixture covering the flange and screws.
Sand to create a smooth finish.
Note: Clean up any sand or plaster inside the fixture.
Finish installing the fixture and power it on to make sure everything works properly.
Align the two fixtures using the alignment pins.
Warning: Keep hands clear of connection.
Connect the two fixtures and use the provided 8-32 set screws to secure the
connecting brackets in place. Lens may need to be removed to access holes
for set screw.
CEILING
DRYWALL SCREW CEILING
SMOOTH FINISH
9
Follow steps 1-6 to install the fixture into the ceiling correctly.
INDIVIDUAL FIXTURES ARE NOT INTENDED FOR CONTINUOUS RUNS.
ADDITIONAL SUPPORTS TO THE STRUCTURE MAY BE REQUIRED.
*CHECK WITH YOUR LOCAL BUILDING CODE FOR THOSE REQUIREMENTS.
GENERAL INSTALLATION CONSIDERATIONS - See submittal drawings for job specific data.
Operating Temperature........................-40°C to 50°C
Operating Voltage.......................................110VAC-277VAC, 50Hz-60Hz
Weight.................................................................... lb/ft
Dimensions........................................................See submittal drawings
·Installation by a certified electrician only.
·Read and understand the installation instructions before attempting to install or use the fixture.
·Only use fixtures with voltage for which it is rated. Do not exceed the specified voltage and current input.
·Do not use the fixture if the housing, lens, or power cable is damaged.
·Ensure that the main power supply is off before installing or wiring the fixture.
·Method of wire connection to be determined by local electrical codes and regulations.
·The external flexible cable of this luminaire cannot be field replaced; if the cord is damaged, contact Coronet.
·The light source contained in this luminaire shall only be replaced by the lighting manufacturer or his service agent or a similar qualified person.