CPG 351SRCPG12NL User manual

User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
Cooking Performance Group . www.cookingperformancegroup.com
3182799
REVISED 04/2022
Countertop
Step-Up Ranges

. www.cookingperformancegroup.com
2
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
Contents
............................................2
........................................3
.............................................3
....................................4
.....................................7
...................................9
Congratulations on your purchase of Cooking Performance Group commercial cooking equipment! At
Cooking Performance Group, we take pride in the design, innovation, and quality of our products. To
ensure optimal performance, we have outlined the following instructions and guidelines in this manual
carefully for your review. Cooking Performance Group declines any responsibility in the event users do not
follow the instructions or guidelines stated here.
*Note: Dimensions do not include 3¼" depth for external regulator.
Specifications
351SRCPG12NL 351SRCPG24NL 351SRCPG36NL
Dimensions*
# of Burners 2 4 6
BTU per Burner 30,000 BTU 30,000 BTU 30,000 BTU
Total BTU 60,000 BTU 120,000 BTU 180,000 BTU
W.C. In 6 NG 10 LP 6 NG 10 LP 6 NG 10 LP
Combustible
Clearances
Floor Clearance 4" 4" 4"
Gas Connection

www.cookingperformancegroup.com 3
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
Safety Precautions
CAUTION:
•
NOTICE:
•
•
WARNING:
•
•
•
Gas Pressure
•
•

. www.cookingperformancegroup.com
4
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
Installation Instructions
NOTE: Installation must be performed by a licensed service technician.
1.
2.
3.
1.
2.
3.
4.
INSTALLATION
GAS CONNECTION
24” Step-Up Countertop Range/Hot Plate
w/ 4 High-Output Burners
Item: 351SRCPG24NL
Gas Type: Natural BTU: 120,000
Orice Size: #43
Manifold Pressure: 6”WC
Serial #:
Lancaster, PA
4003027
Conforms to ANSI STD
Z83.11b-2009 (R2011)
Conforms to CSA STD
1.8b-2009 (R2011)
NSF Tested by ETL
MADE IN CHINA
Intended for commercial use only.

www.cookingperformancegroup.com 5
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
NOTE: These units are factory equipped to be used with a Natural Gas connection. However,
they are eld convertible to Liquid Propane Gas. A licensed installer is required to complete the
following procedure. Orices necessary for LP (propane) are provided in a bag tied to the valve
on the front panel. (If you plan to operate the unit at an elevation above 2,000 ft. please see the
below Gas Elevation Guide to nd the proper orice needed for installation.)
1.
2.
3.
4.
5.
6.
GAS CONVERSION
Fig. 1
Fig. 2
Fig. 5
Fig. 4Fig. 3

. www.cookingperformancegroup.com
6
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
NOTE: If operating this unit at an elevation above 2,000 ft a new orice must be used.
Please consult the below table and nd the correct orice for your application.
GAS ELEVATION GUIDE
EXHAUST SYSTEM
UNDER 2,000 FT. 2,000-4,000 FT. 4,000-6,000 FT. 6,000-8,000 FT. 8,000-10,000 FT.
NG LP NG LP NG LP NG LP NG LP
351SRCPG12NL #43 #52 #44 #53 #45 #53 #46 #54 #48 #54
351SRCPG24NL #43 #52 #44 #53 #45 #53 #46 #54 #48 #54
351SRCPG36NL #43 #52 #44 #53 #45 #53 #46 #54 #48 #54
1.
2.
3.
4.

www.cookingperformancegroup.com 7
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
Operating Instructions
•
•
•
•
•
•
•
•
•
•
•
•
•
CAUTION:
WARNINGS:

. www.cookingperformancegroup.com
8
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
1.
2.
1.
2.
1.
2.
3.
4.
5.
LIGHTING INSTRUCTIONS
LIGHTING MAIN BURNER
MAIN BURNER AIR SUPPLY
LIGHTING PILOT
NOTE: For efcient burner operation, a proper balance of gas volume and primary air supply must be
maintained which will result in complete combustion. Insufcient air supply results in a yellow streaming
ame. Primary air supply is controlled by an air shutter on the front of the burner.
NOTE: The pilot light on the appliance has been set at the factory. A screwdriver may be required for the
rst lighting to adjust the ame for your elevation.

www.cookingperformancegroup.com 9
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
1.
2.
3.
4.
1.
2.
3.
DAILY CLEANING
WEEKLY CLEANING
NOTE: Clean the regulator at least once a month. Also make sure the vent opening is open and not
blocked in any way. Failure to do so will cause variations in pressure. Your unit will not function as well and
it could shorten the life of the product
Cleaning & Maintenance
•
•
WARNING:
Recommended Cleaning Agents
#999SUNBRIGHT
Sunbright
#999KNOCKOUT
Knockout
Blast
#147GRIDDLKLN
Griddle Kleen
This manual suits for next models
2
Table of contents
Other CPG Range manuals

CPG
CPG 351S24(L/N) User manual

CPG
CPG 351CPGSPR18 User manual

CPG
CPG 351RCPG12NL User manual

CPG
CPG HP212 Installation instructions

CPG
CPG 351S24(L/N) User manual

CPG
CPG 351CPGSPR18L User manual

CPG
CPG 351IDCPG19A User manual

CPG
CPG 351S24 Series User manual

CPG
CPG 351WOKR13L User manual

CPG
CPG 351RCPG12NL User manual