Craftmade Targas TG48 User manual

page 1
PRINTED IN CHINA
READ THESE INSTRUCTIONS AND
SAVE THEM FOR FUTURE USE
Installation Guide
For Models:
TG48
TG52
net weight of fan: 14.8 lb (6.7 kg) TG48
14.99 lb (6.8 kg) TG52
Targas
Table of Contents:
Safety Tips. pg. 2
Unpacking Your Fan. pg. 3
Parts Inventory. pg. 3
Installation Preparation. pg. 4
Hanging Bracket Installation. pg. 4
Fan Assembly. pgs. 5 - 7
Wiring. pg. 8
Wiring-Wall Control. pg. 8
Canopy Assembly. pg. 9
Shade Installation. pg. 9
Wall Control Operation. pg. 9
Testing Your Fan. pg. 10
Troubleshooting. pg. 11
Parts Replacement. pg. 11
Warranty. pg. 11

SAFETY TIPS.
WARNING: To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin
the fan installation or before servicing the fan or installing accessories.
1. READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE
INSTRUCTIONS.
CAUTION: To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.
2. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.
If you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the
instructions, please use a qualified electrician.
3. Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven (7) feet (2.13
meters) of clearance between the floor and the fan blade tips. The fan should be mounted so that the tips of the blades are at
least thirty (30) inches (76 centimeters) from walls or other upright structures.
4. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16
kilograms). The outlet box must be supported directly by the building structure. Use only CETL or CUL (Canada) or ETL or UL
(USA) listed outlet boxes marked "FOR FAN SUPPORT."
WARNING: To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of
15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of
lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING: To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept
only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one house
wire to connect to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.
5. Electrical diagrams are for reference only.
6. After installation is complete, check that all connections are absolutely secure.
7. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The
wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the
outlet box.
WARNING: To reduce the risk of electrical shock or fire, do not use this fan with any solid state speed control device or control fan speed
with a full range dimmer switch. [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.]
8. Do not operate the reverse switch until the fan has come to a complete stop. [Note: If using remote control with reverse capability,
reverse fan blade direction only when on LOW speed.]
9. Do not insert anything between the fan blades while they are rotating.
WARNING: To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation. Do not insert objects
into the path of the blades.
WARNING: To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
10. Do not use water or detergents when cleaning the fan or fan blades.A dry dust cloth or lightly dampened cloth will be suitable for
most cleaning.
WARNING: To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER than those provided
with this fan will void the warranty.
WARNING: This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in
personal injury, damage to the fan or damage to other property.
CAUTION: Do NOT tamper with or attempt to repair LED component of fixture.The light source is designed for this specific application
and should not be serviced by untrained personnel. If any servicing is required, call our customer service department.
11. Light kit is dimmable to 10% with select dimmers.
NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This
equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and
situations that may occur. It must be understood that common sense and caution are necessary factors in the installation and operation
of this fan.
page 2

page 3
1. Unpacking Your Fan.
Carefully open the packaging. Remove items
from Styrofoam inserts. Remove motor housing
and place on carpet or Styrofoam to avoid
damage to finish. Do not discard fan carton or
Styrofoam inserts should this fan need to be
returned for repairs.
Check against parts inventory that all parts have
been included.
2. Parts Inventory.
a. canopy. 1 piece
b. hanging bracket. 1 piece
c. downrod and hanging ball (with pin and clip).
1 piece
d. yoke cover. 1 piece
e. canopy cover (in hardware pack). 1 piece
f. motor housing. 1 piece
g. LED light kit (preassembled to motor).
1 piece
h. shade. 1 piece
i. wall control and plate. 2 pieces
j. blade. 3 pieces
k. blade plate. 3 pieces
l. hardware packs
IMPORTANT REMINDER: You must
use the parts provided with this fan for
proper installation and safety.
w/wall
control
k
j
ac
e
h
f
d
i
b
l
g

page 4
3. Installation Preparation.
ON
OFF
ON
OFF
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION: Be sure outlet box is properly grounded and that a
ground wire (GREEN or bare) is present.
Install hanging bracket to outlet box using original screws,
spring washers and flat washers provided with new or
original outlet box.* If installing on a vaulted ceiling, face
opening of hanging bracket towards high point of ceiling.
Arrange electrical wiring around the back of the hanging
bracket and away from the bracket opening.
*Note: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the
fan.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver, adjustable
pliers or wrench, stepladder, wire cutters, and rated
electrical tape.
downrod
installation
flushmount
installation
To prevent personal injury and damage, ensure that
the hanging location allows the blades a clearance
of 7 feet (2.13m) from the floor and 30in. (76cm)
from any wall or obstruction.
The 48in fan is suitable for room sizes up to 225
square feet (20.9 square meters).
The 52in fan is suitable for room sizes up to 400
square feet (37.2 square meters).
7 feet
(2.13 m) (76 cm)
30
inches
blade edge
12ft. - 20ft.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
Vaulted ceiling
angle is not to
exceed 20 degrees.
12ft. - 15ft.
12ft. - 15ft.
(3.66m - 4.57m)
(3.66m - 4.57m)
48in fan
52in fan
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling.The
hanging length can be extended by purchasing
a longer downrod (0.5in./1.27cm diameter).
Other installation, such as flushmount, is not
available for this fan.
hanging bracket
spring washers
outlet box screws
flat washers

page 5
Remove 6 screws and washers from yoke plate
(located on top plate on top of motor housing)
and set aside. Lift yoke plate and top plate to
remove from motor housing and set aside.
Time Saver: Washers can be set on each blade
plate screw prior to installing blades.
WARNING: To reduce the risk of serious bodily
injury, DO NOT use power tools to assemble the
blades. If overtightened, blades may crack and
break.
Locate 9 decorative blade plate attachment
screws and washers in one of the hardware
packs. Hold blade plate up to blade, aligning
posts in blade plate with holes in blade as
shown in diagram. Insert 3 blade plate
attachment screws (along with washers) with
fingers first and then tighten screws securely
with a Phillips screwdriver. Repeat for the
remaining blade plates.
Locate 9 blade attachment screws/washers in
hardware pack. Slide blade through one of the
narrow, rectangular openings on center band,
aligning holes in blade with holes in blade arm
(located inside motor housing). Insert 3 blade
attachment screws/washers with fingers first
and then tighten screws securely with a Phillips
screwdriver. Repeat procedure for each
remaining blade.
Re-attach top plate and yoke plate to yoke
using washers and screws previously removed.
Be sure that semicircular cutout on top plate and
yoke plate aligns over yoke set screws for a proper
fit. (Also make sure that reverse switch aligns
properly with hole for reverse switch in top
plate--see drawing.) Tighten screws to secure
top plate and yoke plate.
["Fan Assembly" continued on next page.]
5. Fan Assembly.
blade
blade plate attachment
screws and washers
blade
top plate
yoke
center band
on motor housing
yoke plate
blade attachment
screws/washers
blade
arms
hole for reverse switch
reverse switch
blade plate

page 6
5. Fan Assembly. (cont.)
Remove hanging ball from downrod provided by
loosening set screw on hanging ball. Remove pin
and clip. Lower hanging ball and remove stop pin.
Slide hanging ball off of the downrod. [Refer to
diagram 1.]
Loosen yoke set screws and nuts at top of motor
housing. [Refer to diagram 2.]
Tip: To prepare for threading electrical wires
through downrod, apply a small piece of
electrical tape to the ends of the electrical
wires--this will keep the wires together when
threading them through the downrod. [Refer to
diagram 2.]
Determine the length of downrod you wish to
use. Thread safety cable and electrical wires
through threaded end of downrod and pull extra
wire slack from the upper end of the downrod.
[Refer to diagram 2.]
Thread downrod into the motor housing yoke
until holes for pin and clip in downrod align with
holes in yoke--make sure wires do not get twisted.
Re-insert pin and clip that were previously
removed. Tighten yoke set screws and nuts
securely. [Refer to diagram 2.]
Locate canopy cover in hardware pack. Slide yoke
cover, canopy cover and canopy over downrod.
[Refer to diagram 3.] (Note: Canopy cover must be
turned with shiny side toward the motor
housing.)
Thread safety cable and wires through hanging
ball; then slide hanging ball over downrod--the
top of the downrod should be noted as having a
set screw hole; use this hole when setting the set
screw. Insert stop pin into top of downrod and
raise hanging ball. Be sure stop pin aligns with
slots on the inside of the hanging ball.Tighten set
screw securely. [Refer to diagram 4.]
WARNING: Failure to tighten set screw on
hanging ball completely could result in the fan
becoming loose and possibly falling.
["Fan Assembly" continued on next page.]
diagram 1
NOTE: The important safety precautions and instructions
appearing in the manual are not meant to cover all
possible conditions and situations that may occur. It must
be understood that common sense and caution are
necessary factors in the installation and operation of this
fan.
set screw
hanging ball
stop pin
pin
clip
diagram 3
canopy
motor
housing
yoke cover
downrod
set screw hole
hanging
ball
stop pin
diagram 2
yoke set
screw
and nut
clip
downrod
wiring safety cable
pin
diagram 4
canopy cover

page 7
5. Fan Assembly. (cont.)
With the hanging bracket secured to the outlet box and
able to support the fan, you are now ready to hang your fan.
Grab the fan firmly with two hands. Slide downrod through
opening in hanging bracket and let hanging ball rest on the
hanging bracket.Turn the hanging ball slot until it lines up
with the hanging bracket tab.
WARNING: Failure to align slot in hanging ball with tab in
hanging bracket may result in serious injury or death.
Tip: Seek the help of another person to hold the stepladder
in place and to lift the fan up to you once you are set on the
ladder.
Find a secure attachment point (wood ceiling joist highly
recommended) and secure safety cable. It will be necessary
to use a heavy duty wood screw, washer and lock washer
(not supplied) with the safety cable loop. If necessary, adjust
the loop at the end of the safety cable.The loop at the end
of the safety cable should just fit over the threads on the
wood screw. Test safety cable by pulling on loose end with
pliers. If the safety cable slips, the loop must be adjusted
tighter. Extra cable slack can be left in ceiling area.
hanging bracket tab
safety cable
wood screw
and washer
safety cable loop
wood
ceiling
joist
motor housing
hanging ball slot

page 8
6.Wiring.
7.Wiring - Wall Control
Remove existing wall switch.Wire the wall
control as shown in diagram at right.
Connect BLACK/WHITE wire from wall control
to BLACK (AC IN L)wire in outlet box. Connect
BLACK wire from wall control to BLACK (AC IN
N) wire from fan (inside the outlet box).
Connect BLUE wire from wall control to BLUE
wire from light in the outlet box. Connect
GREEN/YELLOW ground wire from wall control to
ground wire in the outlet box. Use wire connectors
provided when making connections.
*Wrap each wire connector separately with
electrical tape as an extra safety measure.
Gently push wires and taped wire connectors
into outlet box.
Attach wall control to outlet box and secure
with screws from original wall switch. Attach
plate (included) to wall control using 2 screws
provided with the wall control.
plate
wall control
plate
screw
outlet box
BLACK
(AC IN N
from fan)
BLACK
BLUE
GREEN/
YELLOW
BLACK
(AC IN L) BLACK/WHITE
green/
bare
ground
BLUE
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
WARNING: Turn off circuit breakers to current fixture
from breaker panel and be sure operating light switch is
turned to the OFF position.
CAUTION: Be sure outlet box is properly grounded and
that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to below, please use a qualified electrician.
Note: Excess lead wire length from the fan can be
cut to the desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect BLACK and BLUE wire from fan to BLACK wire
from ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from
ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together from fan
to BARE/GREEN wire from ceiling with wire connector
provided.
If you intend to control the fan light with a separate
light switch, connect BLUE wire from fan to the BLACK
(or RED) supply from the independent switch.
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
*
from ceiling
from fan
ground
(green or bare)

page 9
9. Shade Installation.
Locate slots on shade and align with nodules on
underside of motor housing. Gently push up on
shade and turn to the RIGHT (clockwise) until it
slides completely into place.
Pull down gently on shade to make sure shade is
secured completely.
10.Wall Control Operation.
shade
8. Canopy Assembly.
slots
The wall control is operational for fan and
light (dimmer).
LOW speed
MEDIUM LOW speed
MEDIUM speed
HIGH speed
turns fan OFF
Move slide knob
up or down for
LIGHT brightness
Locate 2 screws on underside of hanging bracket
and remove screw closest to the open end of the
hanging bracket. Partially loosen the other screw.
Lift canopy to hanging bracket. Place rounded part
of slotted hole in canopy over loosened screw in
hanging bracket and push up.Twist canopy to lock.
Re-insert screw that was removed and then tighten
both screws securely.
Slide canopy cover up to canopy, aligning rounded
part of slotted holes in canopy cover with
screwheads in bottom of canopy.Turn canopy cover
to the right (clockwise) until it stops.
screw
canopy
hanging bracket
screw
canopy cover

page 10
11.Testing Your Fan.
It is recommended that you test fan before
finalizing installation. Slide the knobs to “O”
(OFF) position in wall control. Restore power
from circuit box.Test light and dimmer
function and then test fan speeds. If fan
and/or light do (does) not function, please
refer to "Troubleshooting" section to solve
any issues before contacting Customer
Service.
Turn fan completely off before moving the
reverse switch. Set reverse switch to
recirculate air depending on the season:
- LEFT position in summer (diagram 1)
- RIGHT position in winter (diagram 2)
A ceiling fan will allow you to raise your
thermostat setting in summer and lower
your thermostat setting in winter without
feeling a difference in your comfort.
Important: Reverse switch must be set
either completely LEFT or completely RIGHT
for fan to function. If the reverse switch is set
in the middle position (diagram 3), fan will
not operate.
diagram 1 diagram 2 diagram 3
reverse switch
motor housing

page 11
Troubleshooting. Warranty.
WARNING: Failure to disconnect power supply
prior to troubleshooting any wiring issues may
result in serious injury.
Parts Replacement.
Problem: Fan fails to operate.
Solutions:
1. Check power to fan.
2. Check to be sure fan is wired properly.
3. Check to be sure wall control is wired properly.
Problem: Fan operates but light fails.
Solutions:
1. Check to be sure wires in canopy are wired
properly.
2.Verify that wall control is wired properly.
Problem: Fan wobbles.
Solutions:
1. Use the balancing kit provided in one of the
hardware packs. If no blade balancing kit is provided,
please call Customer Support, 1-800-486-4892, to
request one.
2. Check to be sure set screw(s) on motor housing
yoke is (are) tightened securely.
3. Check to be sure set screw on hanging ball is
tightened securely.
PWLI1908
For parts and information, please refer to
"Parts Inventory" on page 2.
Craftmade Customer Support:
1-800-486-4892
www.craftmade.com
CRAFTMADE™ LIFETIME LIMITED WARRANTY:
CRAFTMADE warrants this fan to the original household
purchaser for indoor use under the following provisions:
1-YEAR WARRANTY: CRAFTMADE will replace or repair any
fan which has faulty performance due to a defect in
material or workmanship.Contact Craftmade Customer
Service at 1-800-486-4892 to arrange for return of fan.
Return fan, shipping prepaid, to Craftmade. We will repair
or ship you a replacement fan, and we will pay the return
shipping cost.
5-YEAR WARRANTY: CRAFTMADE will repair or replace, at
no charge to the original purchaser, any fan motor that fails
to operate satisfactorily when failure results from normal
use.
RETURN FAN MOTOR ONLY, shipping prepaid, to Craftmade
Industries.We will repair or ship purchaser a replacement
motor and Craftmade will pay the return shipping cost.
6-YEAR to LIFETIME LIMITED WARRANTY: CRAFTMADE will
repair the fan, at no charge for labor only to the original
purchaser, if the fan motor fails to operate satisfactorily
when failure results from normal use. Parts used in the
repair will be billed to the purchaser at prevailing prices at
time of repair.
The purchaser shall be responsible for all costs incurred
in the removal, reinstallation and shipping of the product
for repairs.
This warranty does not apply when damage from
mechanical, physical, electrical or water abuse results in
causing the malfunction. Deterioration of finishes or other
parts due to time or exposure to salt air is specifically
exempted under this warranty.
Neither Craftmade nor the manufacturer will assume any
liability resulting from improper installation or use of this
product. In no case shall the company be liable for any
consequential damages for breach of this, or any other
warranty expressed or implied whatsoever.This limitation
as to consequential damages shall not apply in states
where prohibited.
This manual suits for next models
1
Table of contents
Other Craftmade Lighting Equipment manuals