CRESTRON CNWMBG2-34A Wall-Mount Wired Panel
REMOTE CONTROL SYSTEMS
2 DOC. 8002B
Specifications subject to change without notice.
Eachunique panel or component on the CRESNET II network requires the setting of an identity code (ID CODE).ID CODES are
two-digithexadecimal numbers, from 10 toFE. The ID CODE ofthe panel should be set tomatch the ID CODE specifiedin the
NET.IDstatement of the CRESNET II SIMPL-C program referencing the panel (refer to syntax section). To set an ID CODE,
removethe panel fromthe electrical box anddisconnect power.
Accessible through the back plate are two miniature circuit-mounted rotary switches, identified as H and L. These 16-
position hexadecimal switches can be set to 0 through F. Using a small screwdriver, rotate the arrow in the center of the
switch marked H to point to the first (or most-significant) digit or letter of the specified ID CODE. Set the switch marked L to
the second (least-significant) digit or letter of the specified ID CODE.
The 4-pin connector marked NET should be wired to the CRESNET II network. Network termination points are available at
the control system power supply. Network units may also be daisy-chained together. Refer to the latest revision of the
CRESNET II reference manual section on CNPWS power supplies (Doc 8017 or Doc. 8091) for wire gauge specifications and
connectiondetails.
Thepanel drawing on the previous page showsthe location of the SIMPL-C button numbersand their corresponding button
positions.Buttons or bargraphs which arenot used need not beassigned a signal name.
REQUIRES:
CRESNET II Workshop Version 4.00 or later.
CRESNET II Operating System SR30160.OPS or later.