Product name : Disinfectant Solution Generator
Model Name : CS-A0250AW, CS-A0250WH
Components : Product, USB cable, User Manual
Weight : 246g
Dimension : H (262mm), D (70mm)
Rated Voltage : DC 5V 1A
Power Consumption : 5W
Capacity : 250ml
Charging time : 3 to 4 hours
Function : Sterilization & Deodorization
Operation mode : 2 modes
- Low : 3 minutes / 4ppm
- High : 6 minutes / 6ppm
(Concentration value may differ depending on the
water quality)
Spray
Water container
Main body
Operation button
(Disinfectant Solution
Generator)
(Generation / Stop making
sterilized water)
Components
USB cable
User manual

Caution for Use
Safety Precautions
1. Please fully charge the product for 3 to 4 hours with
the USB cable enclosed before using the product for
the first time.
2. How to clean the water container
- Fill the water container with 200ml of water.
- Operate the product once.
- Dispose the water.
3. Please use tap water only
4. Please fill at least 200ml of water when using the
product.
5. Battery Indicator : If the LED light keeps blinking in red
and a buzzer alarms, it means the battery is only 20%.
6. USB cable : DC5V, 1~2A (USB micro 5-pin)
Use the USB cable enclosed.
Do not touch the connection part of USB
cable with wet hand as there is a risk of
electric shock.
Check if water leaks during the operation.
Do not use the product without water.
Do not place any heavy object on top of the
product and please place it on a flat surface.
* If the product makes abnormal sound, smells, heat, or smoke,
immediately stop the uses and contact CUCKOO customer center.

Safety precautions
Prohibition
1.Do not drink (it is not drinking water)
2.Do not spray on the face
3.Do not spray on a person’s face (respiratory organs) or a pet
4.Do not use as water for humidifiers
5.Do not use for medical purposes on pets (Do not use for pet skin disease
or wipe tears)
6.Do not use in a place where it is high humidity, wetness, or easily freezing
7.Do not keep in a place where it is direct sunlight, high temperature,
firearms, or high humidity.
8.Use common tap water with temperature between 5 ℃ and 35℃
9.Do not use underground water, contaminated water, or purified water
10.Using with non-specified power and voltage may cause a malfunction
11.Do not use in confined space and make sure to use in well-ventilated place
12.Do not use around heaters and firearms
13.Do not store in a water bottle or in a refrigerator. It can be confused with
drinking water.
14.Do not disassemble or modify the instrument.
15.Be sure to install the product horizontally and do not move the product
while it is operating
16.Be cautious about discoloring or deforming when used in textiles, leather,
or metal.
17.Wear a mask when using.
18,Be cautious about inhaling into the eyes and respiratory organ when
spray into the air
19.This device is not intended for use by people who lack physical, sensory
or mental abilities, or lack experience and knowledge, who cannot use the
device safely without supervision or instruction. (Be cautious not to let
children play with devices.)
20.It may cause the deterioration of the device when store the long period
21.Do not use foreign substances other than water. It may causes the failure.
Risks
1.After using disinfectant solution, rinse with dry or clean water.
2.If the customer disassembles, repairs, modifications, or assembles
this product, they will not receive ‘After Service’ for free.
3.If you soak device into the water, it will cause breakdown and damage.
4.Keep out device from children, infants, or pets.
5.Do not use in chemical storage or a place where the gas is generated
6.Do not use the device while plug, wires, or USB cable is damaged
7.Do not leave the device in the vehicle (in high temperature)
8.Make sure to check leakage before carrying it in your bag
9.Do not drink or inhale on purpose. (If you have inhaled or drunk a
significant volume, make sure to be treated by a doctor)
10.Don't spray it on your eyes. If disinfectant solution has gotten into the
eye, rinse immediately with plenty of water and seek medical attention if
necessary.
11.Wash your hands after using. Avoid contact with sensitive or injured skin.
12.There is an air outlet in the neck of the sprayer, which may cause leakage
if it is flipped over or tilted excessively.
13.Do not store disinfectant solution in a water bottle or in a refrigerator.

www.cuckoo.co.kr / Service inquiry 1588-8899
Precautions during use
1. Make sure to use tap water.
When operating the product with no water or purified water, a buzzer alarms
and the red-colored and blue-colored lamp flickers 5 times. This is an alert for
the absence of water or incorrect use of water so make sure to use tap water.
2. Charge it for at least 1 hour prior to use.
When reusing the product while it is completely discharged, it must be charged
for at least 1 hour before it can properly operate (time needed for a full charge
when it is completely discharged: 3-4 hours).
3.
Clean the electrode part about once a month (to remove scale).
After using it for over a specific period of time, scale adheres to the electrode
part, which reduces the sterilization capability. Make sure to remove scale on
the electrode part about once a month (refer to "Product Management Method"
on how to clean scale).
4. Do not operate the product for 3 or more
consecutive times.
Do not operate the product for 3 or more consecutive times in the
non-sprayed state. It may cause a malfunction.
5. Do not turn the spray by force.
When locking the spray on the water container, do not turn with an excessive
force. The part on which the spray location is fixed may be worn.
To use the product for a long period of time without
a malfunction, make sure to read the
"User Manual" prior to use.

Product description and benefits
The Disinfectant Solution Generator without chemicals
can sterilize and deodorize our daily lives quickly and
easily with more than 99.9% sterilization power through
sterilized water(HOCI) harmless to the human body
made of tap water.
※Test conditions (testing agency: Korean Environment
& Waterworks Institute)
Experimental group
1. Pour tap water into the Disinfectant Solution
Generator provided, operate the product and spray
it on a beaker to fill 20ml of sterilized water
2. Pour 200ml of prepared test sample into the
sterilized water in the beaker and mix them for
30 seconds to analyze
Control group
1. Pour purified water into the specimen(spray) provided
and spray it on a beaker to fill 20ml of purified water
2. Pour 200ml of prepared test sample into the purifier
water in the beaker and mix them for 30 seconds to
analyze
Product description
Sterilization : Sterilizes more than 99.9% of germs
(Klebsiella pneumoniae and 3 other species)
Deodorization : Removes odor when you wipe it off
with tissue or cloth where it smells
Cleansing : Easy to clean when spot or dirt on the
surface of an object
Removal of residual pesticide : Effective in removing
residual pesticide on the surface of fruits and vegetables
Benefits

How to use Disinfectant
Solution Generator
1. Pour 250ml of tap water
2. Press the power button once, and disinfectant solution
is generated for 3 minutes (LOW-Blue LED On)
3. If pressed power button once more, disinfectant
solution is generated for 6 minutes
(HIGH-Please press power button up to 2 times)
4. During disinfectant solution generation, bubbles are
generated.
5. To turn off disinfectant water generation while it is
being generated, please press power button and hold.
6. When LED lamp turns off, disinfectant solution
generation is completed. User is ok to use it.
1. The period of use for disinfectant solution is up to
24 hours. (at ambient temperature)
2. Discard disinfectant solution that was made previous
day. Please use fresh tap water on the day of its use.
- Over production in high density of disinfectant solution
generation will cause rise in internal pressure which may
result in malfunction of the device.
- Make sure to pour tap water up to 250ml or less marked
on the water container.
(Precautions)
How to use

How to charge Disinfectant
Solution Generator
1.Connect the USB cable
2.Connect the adapter on the connection part at the
bottom of the main body
3.It can be used with adapter connected while being
charged
4.The red LED lamp is off when charge is completed
5.Disconnect the cable and seal it with USB cap
Charge the device when fully discharged with 3 times
buzzer sounds and red LED flickers. With complete
discharged, it will require 3~4 hours to fully charge.
* Make sure to check there is no remaining water on the
USB socket or main body of the device when charging
the device.
The USB cable enclosed is compatible with USB charging
adapters for smartphones, computer and vehicles.
However, the charging time will take longer when charging
with computer USB port
(Precautions)
How to charge

How to manage product
Do not keep water inside of sprayer for a long time.
If it is not using for a long time, completely dry inside of
product and store it in place out of moisture and sunlight.
If the product is stored at low temperature, it may cause
malfunction.
Maintenance and Management
Wipe the exterior of the product with dry cloth. Do not
use any chemical or detergent. Make sure not to let water
go inside the connection part of water container and the
main body. If it is wet, wipe it off and dry it completely.
Exterior cleaning
Do not separate the electrode part from main body or
wipe it off with excessive force. If fur created by
containing water for awhile, be cautious not to put
excessive force on the electrode part and wipe it with
dry cloth before rinsing it with tap water.
Interior cleaning
If white scale is observed on the electrode part, pour
200ml of warm water with 20g of citric acid (purchase
separately) or 100ml of water with 100ml of vinegar and
leave it for over 1 hour to automatically cleanse the
electrode. White scale is a lime contained in tap water.
-Do not use detergent or organic solvent / Do not use
cleansing brush, scrub brush, etc.
-Do not cleaning with other product or dishes
Scale cleaning

Various use
Spray it evenly and wash The surface with clean water
after 5 minutes
1. Furniture, leather, woven goods, etc.
in need of sterilization
Put disinfectant solution water on a soft cotton cloth
and wash it with clean water after 5 minutes
2. Sterilization of pet supplies
Fill the container with disinfectant water, place the
products in and wash it after 5 minutes
3. Sterilization of oral supplementary products
such as braces
Spray it evenly and wash The surface with clean water
after 5 minutes
4. Sterilization of leaves and stems of plants
Spray it evenly and wipe the disinfectant solution water
with a clean cotton cloth after 5 minutes
5. Car and supplies cleaning
Fill the container with disinfectant water, place the
supplies such as comb, brushes, clippers and beauty
products in and wash it with clean water after 5 minutes
6. Daily Supplies
Put Disinfectant Solution water on a colth and wipe the
surface to make it sterilized
7. Livingroom
Spray it evenly on your tablewares and wash out the
Disinfectant Solution water with clean water after
5 minutes
8. Kitchen
Fill the container with disinfectant solution water and
put the supplies in it or spray the solution water and
wash out it with clean water after 5 minutes.
9. Bathroom


If you provide us accurate information including the product model name, conditions of
malfunction and contact details, we will always offer friendly and kind consultation and
speedy service for any difficulties, complaints, suggestions and/or proposals you may have.
After reading the manual, make sure to keep it where those who use the product will be
able to access at all times.
The product warranty is included in the user manual.
Note: Make sure to read the user manual if you wish to be able to use the product for a
long period of time without any malfunction.
This manual suits for next models
1
Table of contents
Popular Ultrasonic Jewelry Cleaner manuals by other brands

Stirling
Stirling mwc109 instruction manual

J D UltraSonics
J D UltraSonics sonicom ATLAS Operating and maintenance

SNOWJOE
SNOWJOE SUNJOE 24V-PP350-CT-RM Operator's manual

Graymills
Graymills HANDI-KLEEN PL36 Operation and maintenance instructions

Kärcher
Kärcher WV 6 operating instructions

Vivanco
Vivanco CDC 07 Instructions for use