manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Gateway
  8. •
  9. CyberData SiP Compliant 010846 Manual

CyberData SiP Compliant 010846 Manual

Installation Quick Reference
PoE VoIP Paging Gateway
Sip Compliant
Quick Reference 930097B © 2006 CyberData Corporation ALL RIGHTS RESERVED© 2006 CyberData Corporation ALL RIGHTS RESERVED 930097B Quick Reference
Paging Gateway mounting template
Hole size for Anchor installation: 3/16" (0.1875")
Screws: #6 x 1-1/2" Screw
The PoE VoIP Paging Gateway enables access to existing paging speakers through a VoIP phone system. This gateway
uses a standard paging amplifier and supports paging to multiple zones from a VoIP phone.
Getting started
●Be sure that you have received all the parts described in “Parts list.”
●Download the VoIP Paging Gateway Operations Guide at: www.cyberdata.net—>Support—>Drivers, Utilities &
Manuals—>VoIP Products—>VoIP_Paging_Gateway_Ops_Guide_930098A.pdf
Parts list
Product Specifications
Regulatory Compliance FCC Class A, UL 60950, CE
Power Requirement PoE or +48VDC
Baud Rate 10/100 Mbps
Protocol SiP compliant
Part Number 010846
Dimensions 6.11”L x 4.05”W x 1.15” H
Weight 1.2 lbs.
(1) VoIP Paging Gateway
(2) #6 Mounting Anchors (2) #6 x 1 1/2" Screws
(1) Mounting Template (see the last page)
(1) Mounting Kit
VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
© 2006 CyberData Corporation ALL RIGHTS RESERVED 930097B Quick Reference Quick Reference 930097B © 2006 CyberData Corporation ALL RIGHTS RESERVED
Verifying operations and settings
Contacting CyberData
Front View with LEDs
Back View with Test/ Reset Switch
To announce the Paging Gateway’s current IP
address, press the end of a paper clip into the
Test/Reset switch on the back of the unit. When
the unit beeps after pressing the switch for one
second, release the switch to hear the IP address
announcement.
To restore the Paging Gateway’s factory default
settings, press and hold the Test/Reset switch
while all the indicator lights turn off. Continue to
press the switch until after the indicator lights
turn back on, and then release the switch. All
Paging Gateway settings are restored to the
factory defaults, the unit announces its restored
default IP address, and then announces that it is
rebooting.
●Green Link light indicates network connectivity
●Orange Link light indicates 100Mbps baud rate
●Yellow Link light indicates 10Mbps baud rate
●Blinking yellow Act light indicates network
activity
●Blinking blue Status light indicates the unit is
running
●Green Paging light indicates the unit is paging
Corporate Headquarters
CyberData Corporation
2555 Garden Road
Monterey, CA 93940, USA
Voicemail: 831-373-2601
Fax: 831-373-4193
www.CyberData.net
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
[email protected]
RMA Dept: (831) 373-2601 ext. 136
RMA@CyberData.net
Warranty
CyberData warrants its product against defects in material and
workmanship for a period of two years from the date of purchase. Should
the product fail within the warranty period, CyberData will repair or
replace the product free of charge. This warranty includes all parts and
labor. Should the product fail out-of-warranty, a flat rate repair charge of
one half the purchase price will be assessed. Repair costs for products
that are in warranty, but damaged by improper modifications or abuse,
are charged at the out-of-warranty rate. Products returned to CyberData,
both in and out-of-warranty, are shipped to CyberData at the customer’s
expense. Charges for shipping repaired products to the customer are
paid by CyberData.
For product service, contact the Returned Materials Authorization (RMA)
department. A product will not be accepted for return without an approved
RMA number. Send the product, in its original package, to: CyberData
Corporation, 2555 Garden Road, Monterey, CA 93940, Attention: RMA
“your RMA number”
Typical paging system setup using the Paging Gateway
Mounting (optional) and setting up the PoE VoIP Paging Gateway
Paging Amplifier
VoIP Phone
IP PBX
CyberData PoE VoIP Paging Gateway
Paging Speakers
48VDC
You have the option to use the mounting template
on the last page of this document to mark, and then
drill two 5/32” (0.1875”) holes for the mounting
anchors. Then, install the mounting anchors in the
holes, and position the Paging Gateway mounting
holes over the anchors. Use the two #6 sheet metal
screws to secure the Paging Gateway onto the
mounting surface.
To set up the Paging Gateway:
1. Connect it to your network. To use PoE, plug
one end of an 802.3af Ethernet cable into the
Paging Gateway Ethernet port. Plug the other
end into your network. Or, use a standard
Ethernet cable, and a 48VDC power supply as
directed in Step 3.
2. Connect the Paging Gateway to your paging
amplifier. Plug one end of a modular telephone
cord into the Paging Gateway Line Out port.
Plug the other end into your paging amplifier.
3. When not using PoE, also connect the Paging
Gateway to a 48VDC power supply.
4. Connect the earth grounding wire to the
chassis ground.
Step 1
Step 2
Step 3 (Optional)
Step 4
VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299

Other manuals for SiP Compliant 010846

3

Other CyberData Gateway manuals

CyberData SiP Compliant 010846 User manual

CyberData

CyberData SiP Compliant 010846 User manual

CyberData SiP Compliant 010846 User manual

CyberData

CyberData SiP Compliant 010846 User manual

CyberData VoIP Multicast Gateway User manual

CyberData

CyberData VoIP Multicast Gateway User manual

CyberData SiP Compliant 010846 User manual

CyberData

CyberData SiP Compliant 010846 User manual

Popular Gateway manuals by other brands

Zksoftware Multi Bio 700 manual

Zksoftware

Zksoftware Multi Bio 700 manual

Eurotech Winner Series user manual

Eurotech

Eurotech Winner Series user manual

Watchguard Firebox X1250E Hardware guide

Watchguard

Watchguard Firebox X1250E Hardware guide

Peripheral Electronics PXAMG/PGHGM1 owner's manual

Peripheral Electronics

Peripheral Electronics PXAMG/PGHGM1 owner's manual

Watchguard Firebox SSL Core Hardware guide

Watchguard

Watchguard Firebox SSL Core Hardware guide

HySecurity StrongArmPack DCS 10 installation manual

HySecurity

HySecurity StrongArmPack DCS 10 installation manual

LifeWatch FGL-00005 user guide

LifeWatch

LifeWatch FGL-00005 user guide

NetComm Wireless NF18ACV quick start guide

NetComm Wireless

NetComm Wireless NF18ACV quick start guide

Peripheral Electronics PXAMG owner's manual

Peripheral Electronics

Peripheral Electronics PXAMG owner's manual

i-MO iConnect user manual

i-MO

i-MO iConnect user manual

Alarmcom Smart Gateway ADC-SG130 instructions

Alarmcom

Alarmcom Smart Gateway ADC-SG130 instructions

Ink Bird IBS-M2 user manual

Ink Bird

Ink Bird IBS-M2 user manual

VisionNet GXW 400x reference guide

VisionNet

VisionNet GXW 400x reference guide

3One data GW1108 Series Quick installation guide

3One data

3One data GW1108 Series Quick installation guide

red lion DA70A installation guide

red lion

red lion DA70A installation guide

Multitech MultiVOIP MVP210-SS user guide

Multitech

Multitech MultiVOIP MVP210-SS user guide

Watchguard SSL 1000 Hardware guide

Watchguard

Watchguard SSL 1000 Hardware guide

Black Box EME160A-UC user manual

Black Box

Black Box EME160A-UC user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.