BU600E/BU800E/BU1000E
User’s Manual
K01-C000130-01
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor
area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity
range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing
the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC
power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick
connectors of the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or
batteries. Released electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following: (1) UPS Unit x1; (2) User Manual x1
OVERVIEW
The BU600E/BU800E/BU1000E provides automatic voltage regulation for inconsistent utility power, and
provides battery backup during power outages. The BU600E/BU800E/ BU1000E ensures consistent power to
your computer system.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours
is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur
during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The
unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data
storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. DO NOT plug
a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into
the battery power supplied outlets. The power demands of these devices will overload and possibly
damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, refrigerator, copier, etc. Avoid using extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will
"beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this,
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait
10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the
battery every three months to ensure battery life.
BASIC OPERATION
1. Power Switch
Press the switch for 2 seconds to turn the UPS ON or OFF.
Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button
twice. The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button
twice. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back on, quickly
press the power button twice. You will hear a single short beep when the Alarm is turned on.
2. Led Indicators
This LED is illuminated when the UPS is working.
3. Input Power Cord
Connect to utility power.
4. AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a
power failure and against surges and spikes
TECHNICAL SPECIFICATIONS
DEFINITIONS FOR ILLUMINATED LED INDICATORS
LED
Alarm Condition
On Off Normal
Flash Beep Twice Utility Failure - The UPS is providing battery power to outlets.
Flash Rapid
Beeping
Utility Failure - The UPS is providing battery power. The rapid beeps indicate
the battery will run out of power shortly.
On/Flash Constant
Tone
Overload - Occurs when connected equipment exceeds the rating of the unit.
Turn the UPS off and unplug at least one piece of equipment from the UPS.
TROUBLESHOOTING
Problem Possible Cause Solution
The UPS does not perform
expected runtime.
Batteries are not fully charged. Recharge the battery by leaving the
UPS plugged in.
Battery is slightly worn out. Contact CyberPower Systems
Technical Support.
The UPS will not turn on.
The unit is not connected to an AC
outlet.
The unit must be connected to a
220-240V outlet.
The battery is worn out. Contact CyberPower Systems
Technical Support.
Mechanical problem. Contact CyberPower Systems
Technical Support.
Outlets do not provide power to
equipment
Fuse is blown or breaker is tripped
due to overload.
Turn the UPS off and unplug at least
one piece connected equipment.
Unplug the power cord of the UPS then
replace the blown fuse with a spare
one or press the circuit breaker knob.
Connect power cord then turn the UPS
on. Make sure that your spare fuse
meets the specification.
Batteries are discharged Allow the unit to recharge for at least 4
hours.
Unit has been damaged by a surge or
spike.
Contact CyberPower Systems
Technical Support.
For more information, visit www.cyberpower.com
All rights reserved. Reproduction without permission is prohibited.
Model BU600E-UK BU800E-UK BU1000E-UK
Capacity (VA) 600 800 1000
Input
Voltage Range 165~280Vac
Nominal Frequency 50 Hz
Output
On Battery Output Voltage Simulated Sine Wave at 220Vac +/-5%
On Battery Output Frequency 50 Hz +/-1%
Overload Protection Breaker / Fuse
Physical
Total # of UPS Receptacles 3UK 4(3UK+1IEC)
Dimensions (H x W x D)(mm) 91.5 x 158 x 240 110.5 x 190 x 290
Weight 3.8 kg 4.1 kg 6.9 kg
Battery
Sealed Maintenance Free Lead Acid
Battery RBP0043 x1 RBP0062 x1 RBP0046 x2
Typical Recharge Time 8 Hours
Warning Diagnostics
Indicators Power On / Using Battery
Audible Alarms On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature 0°C to 40°C
Operating Relative Humidity 0 to 90%
Management
Auto-Charger Yes
Auto-Restart Yes

This manual suits for next models

5

Other CyberPower UPS manuals

CyberPower OL6KRTMB User manual

CyberPower

CyberPower OL6KRTMB User manual

CyberPower OR1000LCDRM1Ua User manual

CyberPower

CyberPower OR1000LCDRM1Ua User manual

CyberPower MBP60AHVIEC82U User manual

CyberPower

CyberPower MBP60AHVIEC82U User manual

CyberPower OfficePower 1500AVR-H0 User manual

CyberPower

CyberPower OfficePower 1500AVR-H0 User manual

CyberPower PR5000LCDRTXL5U User manual

CyberPower

CyberPower PR5000LCDRTXL5U User manual

CyberPower Sinewave Series User manual

CyberPower

CyberPower Sinewave Series User manual

CyberPower VP700EILCD User manual

CyberPower

CyberPower VP700EILCD User manual

CyberPower OL6KRT User manual

CyberPower

CyberPower OL6KRT User manual

CyberPower 649532815197 User manual

CyberPower

CyberPower 649532815197 User manual

CyberPower SE425G User manual

CyberPower

CyberPower SE425G User manual

CyberPower UP625 User manual

CyberPower

CyberPower UP625 User manual

CyberPower OP650 User manual

CyberPower

CyberPower OP650 User manual

CyberPower UPS BR850ELCD User manual

CyberPower

CyberPower UPS BR850ELCD User manual

CyberPower EC450G User manual

CyberPower

CyberPower EC450G User manual

CyberPower CPS600E-IN User manual

CyberPower

CyberPower CPS600E-IN User manual

CyberPower CP825LCD User manual

CyberPower

CyberPower CP825LCD User manual

CyberPower ST425 User manual

CyberPower

CyberPower ST425 User manual

CyberPower 3000 VA User manual

CyberPower

CyberPower 3000 VA User manual

CyberPower OL6KRT3UPM User manual

CyberPower

CyberPower OL6KRT3UPM User manual

CyberPower CP900EPFCLCD User manual

CyberPower

CyberPower CP900EPFCLCD User manual

CyberPower BL1250U User manual

CyberPower

CyberPower BL1250U User manual

CyberPower 649532822027 User manual

CyberPower

CyberPower 649532822027 User manual

CyberPower PR5000ELCDRTXL5U User manual

CyberPower

CyberPower PR5000ELCDRTXL5U User manual

CyberPower UP1200 User manual

CyberPower

CyberPower UP1200 User manual

Popular UPS manuals by other brands

TracoPower TSPC240-124UPS Installation instructions manual

TracoPower

TracoPower TSPC240-124UPS Installation instructions manual

PowerWalker VFI 1000RM LCD user manual

PowerWalker

PowerWalker VFI 1000RM LCD user manual

Tripp Lite SmartPro SMART700SER Specification sheet

Tripp Lite

Tripp Lite SmartPro SMART700SER Specification sheet

Tripp Lite 500 VA owner's manual

Tripp Lite

Tripp Lite 500 VA owner's manual

Delta DRU-24V10AMN Operating guidelines

Delta

Delta DRU-24V10AMN Operating guidelines

Vertiv Liebert EXM series user manual

Vertiv

Vertiv Liebert EXM series user manual

PowerShield SAFEGUARD PSG750 user manual

PowerShield

PowerShield SAFEGUARD PSG750 user manual

Energenie EG-UPSO-1000 user manual

Energenie

Energenie EG-UPSO-1000 user manual

Integra OPTIMA RT9 6KVA user manual

Integra

Integra OPTIMA RT9 6KVA user manual

Online YUNTO series user manual

Online

Online YUNTO series user manual

Vertiv Liebert EXL S1 Installer's guide

Vertiv

Vertiv Liebert EXL S1 Installer's guide

ABB i-bus KNX SU/S 30.640.2 product manual

ABB

ABB i-bus KNX SU/S 30.640.2 product manual

Westinghouse SE 3718S manual

Westinghouse

Westinghouse SE 3718S manual

Power Innovations MNL105-153T user manual

Power Innovations

Power Innovations MNL105-153T user manual

Shenzhen 1-10KVA user manual

Shenzhen

Shenzhen 1-10KVA user manual

Eaton DDC-250/2 Instruction leaflet

Eaton

Eaton DDC-250/2 Instruction leaflet

Cyber Power BR1000ELCD quick start guide

Cyber Power

Cyber Power BR1000ELCD quick start guide

ABB PowerScale CABINET A user manual

ABB

ABB PowerScale CABINET A user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.