VP700/1000/1200/1600E(I)LCD
User’s Manual
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate
your UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection.
DO NOT plug the UPS into an outlet that is not grounded. If you need to de-energize this equipment, turn off and
unplug the UPS.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower does not sell products
for life support or medical applications. DO NOT use in any circumstance that would affect the operation and safety
of life support equipment, medical applications, or patient care.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is
disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area,
free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts
inside.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before installing a
computer component.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause the
machine to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the
unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the
damp environment can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following:
(1) UPS Unit x 1; (2) USB Cable x 1; (3) User Manual x 1; (4) Multi-language Quick Start Guide (For EU) x 1 ;
(5) Power Cord x 1 (Type may differ between models.)
OVERVIEW
The VP700/1000/1200/1600E(I)LCD provides automatic voltage regulation for inconsistent utility power, and
provides battery backup during power outages. The VP700/1000/1200/1600E(I)LCD ensures consistent power to
your computer system and its included software will automatically save your open files and shut down your
computer system during a utility power loss.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment does
not exceed the 700VA/1000VA/1200VA/1600VA.
2. Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated
capacity (700VA/390W for VP700E(I)LCD, 1000VA/550W for VP1000E(I)LCD,1200VA/720W for
VP1200E(I)LCD, 1600VA/960W for VP1600E(I)LCD). If rated unit capacities are exceeded, an overload
condition may occur and cause the UPS unit to shut down or the circuit breaker trip.
3. There are many factors that can affect the amount of power that your computer system will require. For optimal
system performance keep the load below 80% of the unit’s rated capacity.
BASIC OPERATION
DESCRIPTION
1. Power Switch
Used as the master on/off switch for equipment connected to the battery power supplied outlets.
2. Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges
and spikes.
3. LCD Module Display
High resolution and intelligent LCD display shows all the UPS information with icons and messages. For more
information, please refer to the Function Setup Guide
4. Display / Select Button
The button can be used to select the LCD display contents including Input Voltage, Output Voltage, and
Estimated Run Time. For more information, please refer to the Function Setup Guide.
5. Mute / Enter Button
The button can be used to silence the alarm, confirm the settings, and enter into the functions. For more
information, please refer to the Function Setup Guide.
6. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet
connection (RJ11/RJ45).
7. Serial/ USB Port to PC
The Serial and USB port allow connection and communication from DB-9 serial or USB port on the computer to
the UPS unit. The UPS communicates its status to the PowerPanel®Personal software.
NOTE: Only one of these two ports can be used as communication and control of the UPS unit at the same
time.
8. Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection
9. AC Input
ConnectAC Power cord to a properly wired and grounded outlet.
10. Battery Backup and Surge Protected Outlets
The unit has several battery powered/surge suppression outlets for connected equipment to ensure temporary
uninterrupted operation of your equipment during a power failure. Check the type and quantity of outlets for
different models in the following table.
11. Surge Protected Outlets
Provides surge protection for devices that don’t require battery backup.
Outlet Type
DE
FR
IEC
AU
Battery Backup & Surge
Protected Outlets
700/1000VA
4
4
6
3
1200/1600VA
4
4
4
3
Surge Protected Outlets
700/1000VA
0
0
0
0
1200/1600VA
1
1
4
1
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is
recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur during
shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will
charge in both the on and off position.
Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. The
first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage
device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser
printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery
power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
3. To protect the network, connect a network cable from the wall jack outlet to the IN jack of the UPS. Then connect
network cable from the OUT jack on the UPS to the computer or network device.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected
by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner,
refrigerator, copier, etc. Avoid using extension cords.
5. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn
the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds.
Make sure the circuit breaker is depressed and then turn the UPS on.
7. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will
automatically recharge.
8. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
9. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery
every three months to ensure battery life.
TECHNICAL SPECIFICATIONS
Model
VP700E(I)LCD
VP1000E(I)LCD
VP1200E(I)LCD
VP1600E(I)LCD
Capacity
700VA/390W
1000VA/550W
1200VA/720W
1600VA/960W
Input
Nominal Input Voltage
220-240V
Voltage Range
167-295Vac
Frequency Range
50/60Hz +/- 5 Hz (Auto Sensing)
AVR Function
Yes
Output
On Battery Output Voltage
220-240V
On Battery Output Frequency
50/60Hz +/-1%
Overload Protection
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Maximum Dimensions (WxHxD)
100 x 227 x 260 mm
100 x 281 x 355 mm
Weight (kg)
5.1 kg
6.2 kg
9.6 kg
10.4 kg
Battery
Sealed Maintenance Free Lead
Acid Battery
12V/7Ah x 1
12V/9Ah x 1
12V/7.2Ah x 2
12V/9Ah x 2
Typical Recharge Time
8 hours
Warning Diagnostics
Indicators
Power On, LCD Display
AudibleAlarms
On Battery, Low Battery, Overload
Environmental
Operating Temperature
0C to 40C
Operating Relative Humidity
0 to 90%
Communication
PowerPanel®Personal Software
Windows 10 / 8 / 7 / Vista / XP / 2000, Server2012 / 2008 / 2003, Linux
Management
Auto-Charger
Yes
Auto-Restart
Yes
USB interface
Yes
Certifications
Certifications
CE, EAC, RCM
FUNCTION SETUP GUIDE
BUTTON DESCRIPTION
Power On:
Press and hold the POWER button. You will hear a constant tone for 1 second,
followed by a short beep. Release the button after the short beep.
Power Off:
Press and hold the POWER button. You will hear a constant tone for 1 second,
followed by two short beeps. Release the button after the two short beeps.
DISPLAY:
Press the button for 3 seconds to change current LCD status between "LCD Sleep in
1 minute (beeps twice)" and "LCD Sleep in 30 minutes (beeps once)".
LCD Sleep in 1 minute: In Line mode, LCD screen will be off automatically
after 1 min of inactivity.
LCD Sleep in 30 minute: In Line mode, LCD screen will be off automatically
after 30 min of inactivity.
In Battery mode, LCD screen will be always on.
SELECT:
Short press the button to view the information about the UPS or scroll down function /
option menu in Setup Mode.
MUTE:
Press the button for 3 seconds to enable the audible alarm (beeps once) or disable
(beeps twice) the audible alarm.
ENTER:
Short press the button to confirm the settings or enter into the functions.
Enter into Setup Mode:
Press both of the “SELECT” and “ENTER” at the same time for approximately 3
seconds to access the setup mode’s 11 functions.
Select Function:
Short press the “SELECT” button to scroll down the function/ option menu.
Short press the "ENTER" button to enter into set up options.
Confirm Option:
When an option is selected, short press the “ENTER” button.
After the setting has been confirmed, the LCD screen will stop flashing.
VP700/1000E(I)LCD
VP1200/1600E(I)LCD
Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per CyberPower UPS Value
Pro 700 VA o cerca il tuo prodotto tra le migliori offerte di Gruppi di Continuità
Copyright © 2019 Cyber Power Systems, Inc. All rights reserved. K01-0000788-00 K01-C000380-00
Function
LCD Display
Options
Default
Description
Utility Power
CUSt: Only when MIN
or MAX I/P Voltage is
configured.
Poor (167V~295V)
Normal (171V~291V)
Good (175V~287V)
ESC
(Escape to Function
Menu)
Poor
This function determines how the
UPS will switch to Battery Mode.
3 different output voltage ranges can
be chosen according to the quality of
the AC utility service in your location.
If your utility service is not stable,
you can select Poor (167V~295V).
The UPS will go to Battery Mode
less often to tolerate the utility power
fluctuations.
If your utility service is stable, you
can select Good (175V~287V). The
unit will go to Battery Mode more
often.
MAX I/P
Voltage
H295, H291, H287
ESC
(Escape to Function
Menu)
H295V
In Utility Power settings, only 3 types
of fixed voltage ranges can be
chosen.
However, you can fine tune the MAX
I/P voltage in this function.
If the utility voltage is usually high,
and the connected equipment can
work in this condition, you can set
the input voltage range higher to
reduce the UPS from going to
Battery Mode as often.
MIN I/P
Voltage
L167, L171, L175
ESC
(Escape to Function
Menu)
L167V
In Utility Power settings, only 3 types
of voltage ranges can be chosen.
However, you can fine tune the MIN
I/P voltage in this function.
If the utility voltage is usually low,
and the connected equipment can
work in this condition, you can set
the input voltage range lower to
reduce the UPS from going to AVR
Mode or Battery Mode as often.
Sensitivity
Low
Medium
High
ESC
(Escape to Function
Menu)
Medium
If the connected equipment can
tolerate more power events
(Example: unstable power often
associated with stormy weather),
select Low Sensitivity. The UPS will
go to Battery Mode less often.
If the connected equipment is more
sensitive to power events, select
High Sensitivity. The UPS will go to
Battery Mode more often.
Low Battery
Warning
5~8 mins
ESC
(Escape to Function
Menu)
5 mins
The audible alarm will sound when
the remaining runtime is less than
the value selected.
Self Test
(Battery Test)
YES
ESC
(Escape to Function
Menu)
No
Action
In Line Mode, select YES to perform
a Self Test on the battery.
Audible Alarm
b.on
b.oFF
ESC
(Escape to Function
Menu)
b.on
"b.on" is buzzer enable;
"b.oFF” is buzzer disable.
If b.oFF is selected, the unit will
mute all alarms except for fault or
overload condition.
You can also set the audible alarm
with the MUTE button mentioned
before.
LCD Sleep
1, 5, 10, 30 min(s)
ESC
(Escape to Function
Menu)
S.1 min
In Line Mode, LCD screen can be
configured to sleep automatically
after 1, 5, 10, or 30 min(s) of
inactivity.
In Battery Mode, LCD screen is
always on.
Last Fault
Reason
There is no setting in this page. This
page will only show the error code
for last fault reason.
E01 : Charger fault (Over Charge)
E02 : Charger fault (No Charge)
E21 : Output short.
E22 : Over load.
Back to
Default
Settings
YES
ESC
(Escape to Function
Menu)
No
Action
Select YES to restore the UPS
factory default settings.
Return to
Status
Display
--
Press the ENTER Button to leave
setup mode and go back to the
Status Display.
TROUBLESHOOTING
Problem
Possible Cause
Solution
Circuit breaker button is
projecting from the back of the
unit.
Circuit breaker has tripped due to
an overload.
Turn the UPS off and unplug at least one piece of
equipment. Wait 10 seconds, reset the circuit
breaker by depressing the button, and then turn
the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged.
Recharge the battery by leaving the UPS plugged
in.
Battery is slightly worn out.
Contact CyberPower about replacement batteries.
The UPS will not turn on.
The on/off switch is designed to
prevent damage by rapidly
turning it off and on.
Turn the UPS off. Wait 10 seconds and then turn
the UPS on.
The battery is worn out.
Contact CyberPower about replacement batteries.
Mechanical problem.
Contact CyberPower.
PowerPanel® Personal is
inactive.
The USB cable is not connected.
Connect the USB / serial cable to the UPS unit
and an open USB / serial port on the back of the
computer.
The unit is not providing battery
power.
Shutdown your computer and turn the
UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
Cyber Power Systems, Inc.
For more information, visit www.cyberpower.com
Manufacturer: Cyber Power Systems Inc.
11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan

This manual suits for next models

4

Other CyberPower UPS manuals

CyberPower PP800 User manual

CyberPower

CyberPower PP800 User manual

CyberPower SMART APP SINEWAVE UPS Series User manual

CyberPower

CyberPower SMART APP SINEWAVE UPS Series User manual

CyberPower CPS525SL User manual

CyberPower

CyberPower CPS525SL User manual

CyberPower Value1200ELCD User manual

CyberPower

CyberPower Value1200ELCD User manual

CyberPower RMCARD400 User manual

CyberPower

CyberPower RMCARD400 User manual

CyberPower BU1000E User manual

CyberPower

CyberPower BU1000E User manual

CyberPower CP1000AVRL User manual

CyberPower

CyberPower CP1000AVRL User manual

CyberPower UPS BR850ELCD User manual

CyberPower

CyberPower UPS BR850ELCD User manual

CyberPower LX1100G3 User manual

CyberPower

CyberPower LX1100G3 User manual

CyberPower Surge Buster SB501BA-FR User manual

CyberPower

CyberPower Surge Buster SB501BA-FR User manual

CyberPower OL1000RTXL2U User manual

CyberPower

CyberPower OL1000RTXL2U User manual

CyberPower SL750U-FC User manual

CyberPower

CyberPower SL750U-FC User manual

CyberPower OL6KRT3UPM User manual

CyberPower

CyberPower OL6KRT3UPM User manual

CyberPower Professional Tower UPS PP1500E User manual

CyberPower

CyberPower Professional Tower UPS PP1500E User manual

CyberPower CP900EPFCLCD User manual

CyberPower

CyberPower CP900EPFCLCD User manual

CyberPower Value 400E User manual

CyberPower

CyberPower Value 400E User manual

CyberPower CPS1100AVR User manual

CyberPower

CyberPower CPS1100AVR User manual

CyberPower CyberShield K01-DC48V2A User manual

CyberPower

CyberPower CyberShield K01-DC48V2A User manual

CyberPower CPS600E-IN User manual

CyberPower

CyberPower CPS600E-IN User manual

CyberPower OfficePower 1250AVR User manual

CyberPower

CyberPower OfficePower 1250AVR User manual

CyberPower CPS600E User manual

CyberPower

CyberPower CPS600E User manual

CyberPower UT1500EG User manual

CyberPower

CyberPower UT1500EG User manual

CyberPower CPS1000AVR User manual

CyberPower

CyberPower CPS1000AVR User manual

CyberPower SM30KPMX User manual

CyberPower

CyberPower SM30KPMX User manual

Popular UPS manuals by other brands

EnerSys DataSafe XE Installation, operation and maintenance manual

EnerSys

EnerSys DataSafe XE Installation, operation and maintenance manual

HPE R1500 G5 Product End-of-Life Disassembly Instructions

HPE

HPE R1500 G5 Product End-of-Life Disassembly Instructions

Qoltec 53973 user manual

Qoltec

Qoltec 53973 user manual

Fideltronik Inigo MY Series user manual

Fideltronik Inigo

Fideltronik Inigo MY Series user manual

LESTAR MC-525 quick start guide

LESTAR

LESTAR MC-525 quick start guide

MGE UPS Systems Evolution 850 Rack 1U Installation and user manual

MGE UPS Systems

MGE UPS Systems Evolution 850 Rack 1U Installation and user manual

nedis UPSD650VBK manual

nedis

nedis UPSD650VBK manual

Eaton 5E650iUSB-AU user manual

Eaton

Eaton 5E650iUSB-AU user manual

ONEAC S07KXAU operating manual

ONEAC

ONEAC S07KXAU operating manual

Powervar SG3K-2TXI Owner's operating manual

Powervar

Powervar SG3K-2TXI Owner's operating manual

PowerShield defender PSD 650 user manual

PowerShield

PowerShield defender PSD 650 user manual

IPM balancedpower plus Installation and operation manual

IPM

IPM balancedpower plus Installation and operation manual

MGE UPS Systems Pulsar MX ModularEasy Quick Installation Startup

MGE UPS Systems

MGE UPS Systems Pulsar MX ModularEasy Quick Installation Startup

OPTI-UPS DS-C33 II Series user manual

OPTI-UPS

OPTI-UPS DS-C33 II Series user manual

Siemens SITOP DC UPS 6EP1931-2EC21 operating instructions

Siemens

Siemens SITOP DC UPS 6EP1931-2EC21 operating instructions

LEGRAND Trimod HE 10 Installation and maintenance manual

LEGRAND

LEGRAND Trimod HE 10 Installation and maintenance manual

Cyber Power OLS1500ERT2UA user manual

Cyber Power

Cyber Power OLS1500ERT2UA user manual

Eaton Powerware 9155 manual 

Eaton

Eaton Powerware 9155 manual 

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.