CyberPowerPC Tracer Liquid Cooling Box User manual

Please read all instructions before using this liquid cooling box and
keep this manual always at hand.
The unit can be operated at an ambient temperature of
max. 35°C (95°F). Do not subject it to temperatures
below 5°C (41°F) or above 35°C (95°F).
CAUTION: Using unauthorized extension cables/tubes will
invalidate your warranty.
CAUTION: Any changes or modifications not expressly
approved by the party responsible for compliance could
void the user's authority to operate this device.
1
To guarantee your rights, please confirm the completeness
of the following information before you use it.
1.Liquid Cooling Box*1 (with rubber lid)
2.Black Dual Head Drain Plug*1
3.Water Tube*2
(with black and silver connectors attached to each end)
4.Hexagon Water Stopper*2
(it is connected to the Liquid Cooling Box)
5.User Manual*1
6.Other Accessories
CAUTION: : We conduct outgoing quality control (oqc)
with distilled water for each Liquid Cooling Box ensuring
a closed loop circuit where no leakage may occur.
MANRLCT011-P111
CAUTION: This product is intended to be supplied by Power
Adapter, output rated 19.5Vdc, 11.8A or 19.5Vdc, 16.9A or
20Vdc, 14A.
Tracer Liquid Cooling Box User Guide

2
Prepare your Liquid Cooling Box
1.Read the User Manual before operating Liquid Cooling Box.
2.Check if the (black and silver) connectors are attached to the
Water Tubes firmly.
3.Gently remove the Hexagon Water Stoppers on the Liquid Cooling
Box (do not throw it away, store it aside as it will be used later).
4.Gently attach (tighten the screws) the black connectors on the
Water Tubes to the Liquid Cooling Box, make sure it is attached
firmly and avoid twisting tubes.
5.Place the Liquid Cooling Box horizontally on the desk.
Attach the black connectors to the Liquid Cooling Box firmly by
tightening the screw. Avoid from twisting tubes while and after
attaching to the Liquid Cooling Box.
Gently remove the Hexagon
Water Stoppers by loosening the
screw and store aside.
CAUTION: Do not use wrench to lock the water pipe.
Tighten with fingers can prevent water leakage.
Improper force may damage the joint.

3
Connect Liquid Cooling Box to the Laptop
1.Place the laptop on the desk, open the rubber flap on the rear
side of the laptop.
2.Insert the silver connector in parallel to the laptop, you will hear a
small click sound when attached correctly (note. refrain from
twisting the Water Tubes and keep it at bent state instead of
straightening the tubes).
3.Connect the power adaptor to the Liquid Cooling Box’s DC port
(note. don’t plug in the power yet).
4.Connect Liquid Cooling Box’s DC Cable to the laptop’s DC port
(note. don’t plug in the power yet).
Parallelly insert connectors
into the laptop.
DC INPUT: 230 Watts (19.5V/11.8A)
280 Watts (20V/14A) Option
330 Watts (19.5V/16.9A) Option

4
Inject water into the Liquid Cooling Box
1.Open the rubber lid on the Liquid Cooling Box, note that the water
injection hole is quite small (ventilation hole is on the right hand
side), recommend using a syringe or funnel for assistance when
injecting water. Also, distilled water is recommended.
2.After filling in distilled water, long press the power button located
on the Liquid Cooling Box for 4-5 seconds. The power button will
glow in purple indicating entering “Water Injection Mode”.
3.Alternatively, open the application “Control Center” in your laptop,
click “Performance” then “Liquid Cooling System Control” module.
Press the “helper” button and click on “Water Injection Mode” to
enter water injection mode.
4.Monitor the water level when injecting the water, add the water
above the MAX indicator for the first time (note. under normal
circumstances, the silver connector will not leak water).
5.Avoid tilting the Liquid Cooling Box, after filling in the water, recap
the rubber lid and make sure that no leakage is observed.
water injection hole

5
Operate your Liquid Cooling Box
1.Plug in the power cord to the power socket.
2.Turn on the laptop and make sure the Bluetooth is turned on as well.
3.Press the power button on the Liquid Cooling Box and the LED
indicator will start glowing.
4.Open the application “Control Center”, click “Performance” then
“Liquid Cooling System Control” module, the application will pop up
“Helper Manual”.
5.After selecting “Device” and Click “connect” button then Liquid Cooling
Box and the laptop will pair via Bluetooth (the fan and water pump
are then activated).
6.Check all ports for leakage after five minutes, if there is, turn off the
power and reconnect the port.
7.The water level drops in standard operation, please add distilled
water and make sure the water level is above the marker indicator
(note. please reference 4-3).
Liquid Cooling Box and laptop will pair automatically via Bluetooth after first pairing:
a, if both are in Bluetooth distance
b, laptop has Control Center installed

6
Disconnect your Liquid Cooling Box
1.Disconnect the Bluetooth via application “Control Center”-
“Performance” - “Liquid Cooling System Control”.
2.Turn off the power (of the Liquid Cooling Box) only when the fan
stopped turning.
Note. The mentioned steps apply to normal installation and usage of
Liquid Cooling Box (e.g. fixed environment).

7
Disconnect the Water Tubes
When you finished using the Liquid Cooling Box, and intend to
disconnect the Water Tubes, please follow the instructions listed below:
1.Turn off the power by pressing the power button on the Liquid
Cooling Box.
2.Gently squeeze the silver connector which is connected to the laptop
and remove it from the laptop horizontally.
Squeeze the silver connector and remove
it from the laptop horizontally.
To reduce the possibility of heat-induced injury or equipment overheating:
1. In the case that the connector is connected and the water is not flowing, the
connector may accumulate heat in the metal part because of the temperature generated
by the operation of the system, so please be aware of the high temperature.
2. If you want to remove the quick release connector, make sure the Liquid Cooling Box
is turned off (to avoid water leakage) and test the connector by hand to make sure the
temperature is not too high before removing it.

8
Change water or Travel
If you are to change the water or need to travel, please follow the
instructions listed below:
1.Since system operation may lead to accumulated heat in the silver
connector, recommend removing the connector horizontally only after
turning off the device.
2.Insert into laptop’s drain tubes (4mm deep) to assist draining
additional liquid in the laptop.
3.Put laptop’s rubber flap back on (squeeze it tight) to avoid minor water
leakage.
4.Insert on to the silver connector to drain the liquid in the Liquid
Cooling Box.
5.Remove the Black Dual Head Drain Plug when the liquid is emptied, and
gently tighten the Hexagon Water Stoppers on to the drain port.
If you intend to remove the Black Dual Head Drain Plug, squeeze the silver
connector to unlock and remove it after.
1.If you need to travel, please empty the liquid in the Liquid Cooling Box, Water Tubes,
and laptop’s liquid cooling copper pipes to avoid water leakage during transportation,
which may lead to device malfunction.
2.To prevent from water scale, please change the water regularly.
3.Check if there are water leakage when connecting or disconnecting the device, and
clean up in time.
1
2
1
2

Front side view/ Back side view
Left side view/ Right side view
The power cord can be stored around the base
9
Product Overview
1
3
4
5
2

Top side view/ Bottom side view
1
2
3
4
5
6
Drain Pipes
RGB LED
DC Port
Vents
Power Connector
Rubber Lid
LED Indicator*
Power Button
7
8
6
7
8
*(Colors for BT/Pump injection water/ lightbar)
1. Water injection : Blinking(Purple color)
2. BT searching :Blinking (Blue color)
3. BT ready : on (Blue color)
4. Liquid cooling system error : Blinking
(Pump idling _Orange color)

Trouble Shooting Guide
1.If water leakage occurs: please disconnect the device immediately and
check if Liquid Cooling Box’s ports are connected firmly, all ports
should be tightened to ensure all pipes are sealed.
2.Check if the laptop and Liquid Cooling Box is paired properly via
Bluetooth before activating the Liquid Cooling Box, if not:
2-1. Check if the power if turned on and connected.
2-2. Check if the Control Center is installed.
2-3. Check if laptop’s Bluetooth is turned on.
2-4. Restart laptop and Liquid Cooling Box so it can pair again.
3.When Liquid Cooling Box’s water pump is malfunctioning: the power
button will flicker in red light and shut down automatically after 10
seconds.
4.When there is more air in the Water Tubes: use Black Dual Head Drain
Plug and insert it into the silver connector for two seconds, then
squeeze the Water Tubes and lean the Liquid Cooling Box to drain the
air out ( please note that there’s no leaking from the Water Tank).
Device Maintenance
1.Replace the water in Liquid Cooling Box’s water tank regularly, check
4 Inject water into the Liquid Cooling Box, 7 Disconnect the Water
Tubes and 8 Change water or Travel for more details.
2.When using Liquid Cooling Box in sub-zero temperature, please drain
the water completely after every usage, to prevent the pipes from
frost crack.
3.Using distilled water is recommended.
10

Note.
1.Due to different water quality, mineral water has higher chance if water
scaling.
2.Coolant and chemical toxic liquid are not recommended.
3.Pleas do not connect to power before water injection (only turn on the
power/ connect to power if it is filled with water).
4.IIF there is abnormal noise coming from the pump, this could be the
result of air bubbles still trapped inside the tubes, Trouble shooting steps
are as below:
4.1 Disconnect the “2 in 1 Quick release connector” from the rear side of
the laptop and use the provided tool (item illustrated in Page 7) and
insert into the “2 in 1 quick release connector” to allow the water to flow
out for 2 seconds.
4.2 Pinch and release the right tube repeatedly for a few times.
4.3 Tilt the Liquid Cooling Box left slightly or backwards and hold this
position for 3 seconds before placing it back into original position.
(Please note* when following the above steps, the top Lid of the box
must be capped on at all times to prevent water leakage.)
Reminder
1.Please read the User Manual before operating the device.
2.Please check all ports in case of water leakage before powering up the
device.
3.In the case that the connector is connected and the water is not flowing,
the connector may accumulate heat in the metal part because of the
temperature generated by the operation of the system, so please be
aware of the high temperature.
4.If you want to remove the quick release connector, make sure the Liquid
Cooling Box is turned off (to avoid water leakage) and test theconnector
by hand to make sure the temperature is not too high before removing it.
5.Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
this device.
6.Using unauthorized extension cables/tubes will invalidate your warranty.

Regulations Information
CE compliance
This device is classed as a technical information equipment (ITE) in class B
and is intended for use in living room and office. The CE-mark approves the
conformity by the EU-guidelines:
- EMC Directive 2014/30/EU,
- Low Voltage Directive 2014/35/EU(equals A2 : 2013) ,
- RF Directive 2014/53/EU
FCC Information
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-Consult the dealer or an experienced radio/ TV technician for help.
CAUTION: Any changes or modifications not expressly approved by the grantee of this
device could void the user's authority to operate the equipment.

CAUTION: Any changes or modifications not expressly approved by the grantee of this
device could void the user's authority to operate the equipment.
RF Exposure Warning
This equipment must be installed and operated in accordance with
provided instructions and the antenna(s) used for this transmitter must
be installed to provide a separation distance of at least 20cm from all
persons and must not be co-located or operating in conjunction with any
other antenna or transmitter. End-users and installers must be provide
with antenna installation instructions and transmitter operating
conditions for satisfying RF exposure compliance.
Table of contents
Popular Computer Hardware manuals by other brands

hilscher
hilscher CIFX M3042100BM-DP/F user manual

Measurement Computing
Measurement Computing Data Translation DT3034 user manual

EK-Quantum
EK-Quantum Reflection PC-O11D Mini D5 PWM D-RGB user guide

mikroElektronika
mikroElektronika multimedia workStation v7 user guide

MF DIGITAL
MF DIGITAL Scribe PC Operator's guide

BTSX
BTSX BIT-MSE-U1-312 manual