3
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following.
Read all instructions before using this appliance.
WARNING – To reduce the risk of re, electric shock, or injury:
1. Do not leave appliance unattended when plugged in. Unplug from outlet when
not in use and before maintenance.
2. Do not use outdoors or on wet surfaces.
3. Do not allow to be used as a toy. Close attention is necessary when used
by or near children or disabled persons. This appliance is not intended for
use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a person
responsible for their safety.
4. Cleaning and user maintenance shall not be made by children without
supervision.
5. Use only as described in this manual. Use only manufacturer’s recommended
attachments.
6. Do not use with damaged cord or plug. If appliance is not working as it should,
has been dropped, damaged, left outdoors, or dropped into water, return it to
a CycloVac service center.
7. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull
cord around sharp edges or corners. Keep cord away from heated surfaces.
8. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
9. Do not handle plug or appliance with wet hands.
10. Do not put any objects into openings. Do not use with any opening blocked;
keep free of dust, lint, hair, and anything that may reduce air ow.
11. Keep hair, loose clothing, ngers, and all parts of body away from openings
and moving parts.
12. Do not vacuum anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
13. Do not use without dust bag and/or lter(s) in place.
14. Turn off all controls before unplugging.
15. Use extra care when cleaning stairs.
16. Do not use to pick up ammable or combustible liquids such as gasoline or
use in areas where they may be present.
17. Connect to a properly grounded outlet only. See Grounding Instructions.
KEEP THESE INSTRUCTIONS


5
Table of Contents
Preface 6
Schematic – GS115 model 6
Schematic – E, GS & H series 7
Schematic – DL, GX & HX series 8
Schematic – DL/GX/HX7515 model 9
INSTALLATION
Unit installation 11
Dos and Don’ts - inlet installation 12
Mufer installation 13
Electric connections 14
Grounding instructions 15
Low voltage connections 16
OPERATING INSTRUCTIONS
Hose hook-up & inlets 17
Progressive start 18
Automatic stop 18
DataSync monitor 19
DataSync hose 20
MAINTENANCE
Motor 21
Carbon dust lter 21
Dirt receptacle 21
E & DL series - lters 22
GS & GX - electrostatic bag 23
Antimicrobial permanent lter 23
GS115 model - disposable bag & lter 24
H & HX series - hybrid ltration 25
TROUBLESHOOTING
General information 27
Decrease in suction strength 28
Vacuum will not start 30
Vacuum will not stop 31
WARRANTY INFORMATION
Limited lifetime warranty 32
One year satisfaction guarantee 33
Warranty on CycloVac attachments 33
WEEE directive 34

2
3
1
4
5
6
6
min. 30 cm (12") min. 30 cm (12")
GS115 MODEL
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
6. Air Intake
5. Air Exhaust
6. Mufer
Preface
Your new CycloVac central vacuum system was designed and manufactured in
Blainville, Quebec, by the largest central vacuum cleaner manufacturer in Canada.
With over fty years of experience in the vacuum eld, we provide a high-quality,
state-of-the-art product, and guarantee your complete satisfaction. Our extensive
network of qualied professionals ensures rst quality service near you. Contact
us for the location of the CycloVac authorized dealer in your area, or visit our
website: www.cyclovac.com.
Schematic
min. 5 cm (2")
min. 30 cm (12")
Recommended 40 cm (16")
With mufer turned down,
min. 30 cm (12")

2
3
4
6 5
1
7
7
Schematic
E, GS & H SERIES
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Air Intake
5. Mufer
6. Carbon Dust Filter (E/GS/H 315, 715 & 2015 models only)
7. Air Exhaust
min. 30 cm (12")
min. 30 cm (12")
Recommended 40 cm (16")
With mufer turned down,
min. 30 cm (12")
min. 30 cm (12")
min. 30 cm (12")

2
3
4
7
1
6
5
8
8
Schematic
DL, GX & HX SERIES
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. DataSync LCD Monitor
5. Air Intake
6. Mufer
7. Carbon Dust Filter
8. Air Exhaust
min. 30 cm (12")
min. 30 cm (12")
Recommended 40 cm (16")
With mufer turned down,
min. 30 cm (12")
min. 30 cm (12")
min. 30 cm (12")

1
2
3
4
5
10
6
7
main
unit
8
9
motor
head
9
*In this case, this intake should be sealed with a cap.
Schematic
GX/DL/HX7515 - INSTALLATION IN SERIES
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Air Intakes (seal the unused air intake with the provided cap)
5. Intake for Installation in Parallel*
6. Intake for Installation in Series
7. Mufer
8. Air Exhaust
9. Carbon Dust Filters
10. DataSync LCD Monitor

1
2
3
4
10
5
6
7
main
unit
8
9
motor
head
10
Schematic
GX/DL/HX7515 - INSTALLATION IN PARALLEL
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Air Intakes (seal the unused air intake with the provided cap)
5. Intake for Installation in Parallel
6. Intake for Installation in Series
7. Mufer
8. Air Exhaust
9. Carbon Dust Filters
10. DataSync LCD Monitor

gure 1
gure 2
11
Installation
Unit Installation
Using the wall bracket provided with your
vacuum cleaner, secure the unit to the wall
(gure 1), at a height allowing easy access
to change the bag or empty the canister.
Contrary to all other connections in the
piping system, do not glue the last tting
to your unit. CycloVac central vacuums
are equipped with an adjustable air intake
valve (gure 2), which does not require
glue. An air-tight t is obtained with the
screw-type adjustment on the tting itself.

12 Installation
INSTALLING INLETS
When installing your vacuum inlets, we recommend that the principle of electric
polarity be taken into account. Ensure that the wire connected onto contact A on
inlet 1 is the same as that connected to contact A on inlet 2, and so on. Do not
cross, reverse or interchange wires.
Dos & Don’ts
A
B
INLET 1
INLET 2
A
B
A
B
INLET 1
INLET 2
A
B

Glue not included. Glue not included.
13
Installation
Muffler Installation
1. Insert the rubber coupling on the vacuum air exhaust.
2. Using a Phillips screwdriver, tighten the clamp collar to ensure
adequate sealing.
3. Insert the 90° elbow into the rubber coupling, and tighten the clamp
collar as per instructions in step 2.
4. Apply ABS glue to the 90° elbow and insert mufer.
GS115 MODEL
95, 215, 315, 615, 715 & 2015 MODELS
A. Rubber coupling
B. 90° elbow
C. Mufer
D. Air Exhaust
AB
C
D
A
D
B
C
Glue not included.
7515 MODELS
AB
C
D

14 Installation
There should be an electric outlet within 1 meter (3 feet) of your central vacuum
unit. Once the appliance is installed in a suitable location, connect your central
unit to an electric outlet on a dedicated* grounded circuit. Do not use extension
cords or modify the length of your vacuum cleaner’s power cord.
DEDICATED* GROUNDED CIRCUIT
r/PSUI"NFSJDB
120 V / 240V all models: 15A
r&VSPQFBODPOUJOFOUBOEPUIFS
220 V / 240V model 7515: 15 A
220 V / 240V models 615, 715 and 2015: 10 A
220V / 240 V models 95, 115, 215, 315: 8A
Your central vacuum cleaner has a thermal safety device / circuit breaker to
protect it against any over voltage or electrical defect. If that protection should
fail, contact your authorized dealer.
*Please reserve a circuit breaker dedicated only to the connections for your
central vacuum.
If you nd that installing your vacuum cleaner is too difcult, ask your service
center to install it for you. When in doubt, it is better to have the work done by a
professional and ensure that the unit is properly installed. Any installation that
does not comply with the specied norms could alter or invalidate the warranty.
Electric Connections

Type C Type G Type H Type I Nema 6-15 R
gure 4
15
Installation
This appliance must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This appliance is equipped with a cord that has an
equipment-grounding conductor and grounding plug. The plug must be inserted
into an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances. No adaptor should be used with this
appliance.
WARNING
Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualied electrician or service technician if you
are in doubt as to whether the outlet is properly grounded. Do not modify the
plug provided with the appliance – if it will not t the outlet; have a proper outlet
installed by a qualied electrician.
120V MODELS
This appliance is for use on a nominal 120V circuit, and has
a grounded plug. Make sure that the appliance is connected
to an outlet having the same conguration as the plug. No
adaptor should be used with this appliance.
220V/240V MODELS
This appliance is for use on a circuit that has a nominal rating of more than 120V
and that is factory-equipped with a specic cord and plug to permit connection to
a proper electric circuit. Make sure that the appliance is connected to an outlet
having the same conguration as the plug. No adaptor should be used with this
appliance. If the appliance must be reconnected for use on a different type of
electric circuit, the reconnections should be done by a qualied service technician.
Grounding Instructions

gure 4gure 3
gure 5 gure 6
16 Installation
Low Voltage Connections
Connect the low voltage wires to the low voltage inlet on your unit.
To do so:
1. Strip wires over 1 cm (½ inch) (gure 3).
2. Gently press on the toggle to open the connector (gure 4).
3. Insert stripped wire (gure 5).
4. Release toggle to secure wire in connector (gure 6).
5. Repeat steps 2 to 4 for second connector.
To disconnect:
1. Gently press on the toggle to open the connector.
2. Remove low voltage wire from connector.

gure 7
17
Operating Instructions
Hose Hook-up & Inlets
#FGPSFPQFSBUJOHZPVSDFOUSBMWBDVVNw
Please verify that your central vacuum is properly connected to the piping system
and to a grounded electrical outlet, and that the low voltage wires are connected
to the unit (see pages 14 to 16). Then, read the complete owner’s manual and
proceed with a quick verication of your unit’s installation:
r $IFDLCBHBOEàMUFSUPNBLFTVSFUIFZBSFQSPQFSMZJOTUBMMFEBOEOPUEBNBHFE
r $IFDLSVCCFSTFBMTJOFBDIWBDVVNJOMFU
To start your central vacuum, simply insert the hose in the vacuum inlet of your
choice. Please ensure that the tab on the hose end is properly lined up with the
slot in the inlet opening (gure 7). If your hose handle has an integrated on/off
switch, simply slide the switch to the “on” position.
Do not try to open another inlet while your system is in operation, as it may
damage the inlet’s rubber seal.
r 8IJMFUIFIPTFJTTUJMMQMVHHFEJOUPPOFJOMFUBOEUIFTZTUFNJTPQFSBUJPOBM
check other inlets for leaks.
r 1MVHUIFIPTFBMUFSOBUJWFMZJOUPFBDIWBDVVNJOMFUUPFOTVSFUIBUFBDIPOF
works properly.

18 Operating Instructions
Automatic Stop
Progressive Start
(DL, GX & HX Series)
Each DL, GX & HX model is equipped with a special module allowing for a smooth
and gradual start-up of the vacuum system, to prolong motor durability.
(DL, GX & HX Series)
In case you’ve forgotten to turn off your vacuum, or it’s been turned on by mistake,
your vacuum system will automatically shut off after one hour of uninterrupted
use. The four LEDs on the DataSync hose handle will ash, indicating an
automatic shutoff. Simply restart the vacuum system with the switch on the hose
handle.

2
1
4
3
6
7
5
19
Operating Instructions
(DL, GX & HX Series)
Your central vacuum unit is equipped with an electronic timing device that will
recommend proper maintenance of your vacuum system. These signals are only
suggestions and do not indicate a problem with your vacuum system. They will not
stop or hinder the use of the vacuum.
cTimer – indicates hours the unit has been
operated
dFlashing wrench – mechanical maintenance of the
power unit is recommended
eTurbine
Without movement – unit is connected to a power
source
Movement – unit is turned on - operating
Speed of movement according to power level
chosen
fFlashing Bag – GX series: check the bag, and
change if necessary.
HX series: check the bag or the canister, and
change/empty if necessary.
gFlashing Filter – DL series
Empty dust recipient and clean lters
hFlashing Carbon Dust Filter
Replace lter
iReset – to stop the ashing icons, press the reset
button for one second.
Please note that maintenance information provided by these four icons (2, 4, 5,
and 6) will also appear on the DataSync hose handle (see details on next page).
DEMO MODE
Demo mode: to initiate a demonstration of the Information Center on the power
unit, press the reset button ifor 5 seconds. To stop the demonstration, simply
press the reset button i.
DataSync Monitor

21
4
3
5
20 Operating Instructions
The light emitting diodes on the DataSync hose will
signal, by ashing, that it is time to change the bag or
empty the canister, and even when maintenance is
required. They do not indicate a problem with the
vacuum system, and will not hinder or stop the use
of the vacuum power unit.
c'MBTIJOH-&%PWFS#BHJDPO
GX series: check the bag, and change if necessary.
HX series: check the bag or the dust canister and change/
empty if necessary.
'MBTIJOH-&%PWFS'JMUFSJDPO
DL series only – empty dust recipient and clean lters
d'MBTIJOH-&%PWFS$BSCPO%VTU'JMUFSJDPO
Replace lter
e'MBTIJOH-&%PWFS8SFODIJDPO
Maintenance of the power unit is required.
fFour green LEDs indicate the power level chosen. When all
four ash, they indicate an automatic shut-off (after one hour of uninterrupted
use). Simply restart the power unit by pressing the hose handle switch.
gPress the power button to start the power unit at full power. To reduce power
level, press briey on the switch. Power level will reduce by one level. From
power level 1 (lowest), the power unit will proceed to power level 4 (highest).
To stop the power unit, keep pressing the switch for 2 seconds.
DEMO MODE:
Demo mode: If you initiate a demonstration of the DataSync Information Center on
the power unit, (by pressing the reset button on the vacuum unit for 5 seconds) the
hose will also enter a demo mode of LEDs. To stop the demonstration, simply press
the power button on the hose handle gfor one second.
DataSync Hose
(DL, GX & HX Series)
This manual suits for next models
12
Table of contents
Languages:
Other Cyclo Vac Vacuum Cleaner manuals

Cyclo Vac
Cyclo Vac Tradition E100 User manual

Cyclo Vac
Cyclo Vac HD Series User manual

Cyclo Vac
Cyclo Vac HD Series User manual

Cyclo Vac
Cyclo Vac HE User manual

Cyclo Vac
Cyclo Vac Tradition GS115 User manual

Cyclo Vac
Cyclo Vac Ultra-Fresh User manual

Cyclo Vac
Cyclo Vac GS Series User manual

Cyclo Vac
Cyclo Vac GS71 User manual