INSTRUCTION MANUAL
(V2.3)
HOUSEHOLD INTERCOM
SMART-5PG
UNIPHONE REGULATION ELEMENTS
1. The main connector for link the uniphone with control
panel
2. Microphone sensitivity adjustment
3. Unit configuration jumpers
4. Multifunction button connector
5. Multifunction button
6. Lock release button
7. 3-position call signal's volume control switch:
- loud call
- medium call
- no sound
8. Call generator mode jumper
-6-
-5-
Internal call generator External call generator
MULTIFUNCTION BUTTON (5)
The multi-function button is used to connect additional
devices (light switches, gate control etc.) It is indepen-
dent from the intercom system and is a regular short
circuit button.
Maximum Load: 200mA 12V AC/DC
INSTALLATION OF A 6-WIRE INTERCOM
1
3
782
6
4
5
1
Common ground
Call
Speaker
Microphone
Lock release
Lock release ground
2
Set the configuration
jumpers as in the
picture
Jumper
CALL GENERARTOR MODE JUMPER
Some systems require to use of an internal call genera-
tor. To enable this feature jumper need to be set on po-
sition 2-3. When external ring generator is used, jumper
need to be set on position 1-2.
Manufacturer:
CYFRAL Chabelska i Wspolnicy S.J.
ul. Konstantynowska 62/70
95 - 100 ZGIERZ POLAND
www.cyfral.pl