Daewoo DAEPC-11A User manual

Manufactured under license of Daewoo International Corporation, Korea
www.daewoopowerproducts.com
USER'S MANUAL
DAEPC-11A
Automatic pressure switch
1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S
MOTORS
3. POSSIBLE WORKING DEFECTS
4. UNIT STARTING AND WORKING
WARNING: Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to make correct connection.
Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9
mm max. One of the leading end of the cable must be lower than the position of the fixing screws
while the cable being connected to the power as shown in the fig.
The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid
water entering into the control box and damaging the electronic circuit.
6. TECHNICAL DATA
Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1"male
Protection rating: IP54

INDEX
1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION
..................................................................... 2
2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS
OF PUMP’S MOTORS
................................................................................................................................ 3
3
. POSSIBLE WORKING DEFECTS ........................................................................................................... 3
4
. UNIT STARTING AND WORKING ........................................................................................................... 4
6. TECHNICAL DATA
.................................................................................................................................. 4
WARRANTY ................................................................................................................................................. 5
1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S
MOTORS
3. POSSIBLE WORKING DEFECTS
4. UNIT STARTING AND WORKING
WARNING: Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to make correct connection.
Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9
mm max. One of the leading end of the cable must be lower than the position of the fixing screws
while the cable being connected to the power as shown in the fig.
The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid
water entering into the control box and damaging the electronic circuit.
6. TECHNICAL DATA
Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1"male
Protection rating: IP54
1

EN
1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S
MOTORS
3. POSSIBLE WORKING DEFECTS
4. UNIT STARTING AND WORKING
WARNING: Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to make correct connection.
Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9
mm max. One of the leading end of the cable must be lower than the position of the fixing screws
while the cable being connected to the power as shown in the fig.
The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid
water entering into the control box and damaging the electronic circuit.
6. TECHNICAL DATA
Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1"male
Protection rating: IP54
It is advisable to
connect the unit outlet
to the system by means
of a flexible hose.
If the column of water between
the pump and the highest tap
exceeds 15 mts, the unit cannot
be installed directly on the pump,
but it has to be raised until the
column of water between the unit
and the highest tap does not
exceed 15 mts.
I.E. If column of water is 20 mts.
from the pump, the unit musb be
places 5 mts higher than the
pump.
The unit is equipped with a
check valve to prevent the
pipeline from losing pressure.
No taps can be installed
between the pump and
the unit.
Pump´s pressure
The unit is pre-set by the
manufacturer at a restarting
pressure of 1.5 bar.
The pressure produced by the
pump must be normally 0.8 bar
higher than the pre-set pressure.
Before starting the unit check
suction and ensure that the
pump is primed.
It´s imperative to install
the unit with the arrows
in the upward position.
The unit can be installed
directly on the pump, or
between the pump
and the first tap.
15 mts max
2

1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S
MOTORS
3. POSSIBLE WORKING DEFECTS
4. UNIT STARTING AND WORKING
WARNING: Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to make correct connection.
Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9
mm max. One of the leading end of the cable must be lower than the position of the fixing screws
while the cable being connected to the power as shown in the fig.
The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid
water entering into the control box and damaging the electronic circuit.
6. TECHNICAL DATA
Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1"male
Protection rating: IP54
contactor contactor
Wiring diagram for
connection of single
-phase 220V pumps
up to 1.1 kW.
Wiring diagram for connection
of single-phase 220V pumps
over 1.1 kW. Through
remote control switch.
SPECIFICATIONS FOR
REMOTE CONTROL SWITCH
Minimum contacts capacity of
4 kW or 5.5 hp approx
220V
SPECIFICATIONS FOR
REMOTE CONTROL SWITCH
Minimum contacts capacity of
4 kW or 5.5 hp approx
220V
Wiring diagram for connection
of three phase 380V motor
pumps through remote control
switch.
L1-1-5 0- 60 H z 22 0-2 40V L1-1-5 0- 60 H z 22 0-2 40V
L1-1-5 0- 60 H z 22 0-2 40V
TYPE OF DEFECT
- The pump does
not start
- The pump does
not stop
- Intermittent
pump working
- The pump is
jammed
- The electronic card is broken
- The electronic card is broken
- The flow detector is blocked in
the upper position
- The reset button is broken
- The pump does not provide
sufficient pressure
- The electronic card is broken
- The pump does not provide
sufficient pressure
- The electronic card is broken
- The pump provides a pressure
which is lower than the
restarting pressure
- Voltage failure
- Pump is jammed
- Electric cables inverted
(line/motor)
-Presence of leaks which are
higher than the minimum
flow 2 L/min
- Presence of leaks which are
lower than the minimum
flow 2 L/min
- Water failure
- Suction problems
CAUSES DEPENDING
ON THE UNIT
CAUSES NOT DEPENDING
ON THE UNIT
3

EN
1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S
MOTORS
3. POSSIBLE WORKING DEFECTS
4. UNIT STARTING AND WORKING
WARNING: Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to make correct connection.
Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9
mm max. One of the leading end of the cable must be lower than the position of the fixing screws
while the cable being connected to the power as shown in the fig.
The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid
water entering into the control box and damaging the electronic circuit.
6. TECHNICAL DATA
Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1"male
Protection rating: IP54
This part must be lower
than the fixing nuts.
Power
Pump
Inlet
Three-wire cable
with the OD 7.5-9 mm
4

GUARANTEE
WARRANTY DOES NOT COVER
Product model
Serial number
Username
Date of sale
Company
Client's signature
The warranty period starts from the date of sale of the products and covers 1 year for all power products.
During the warranty period, free failures caused due to the use of poor-quality materials in the production and
manufacturer workmanship admitted fault are removed. The guarantee comes into force only when warranty card
and cutting coupons are properly filled. The product is accepted for repair in its pure form and full completeness.
• Mechanical damage (cracks, chips, etc.) and damage
caused by exposure to aggressive media, foreign objects
inside the unit and air vents, as well as for damage occurred
as a result of improper storage (corrosion of metal parts);
• Failures caused by overloading or product misuse, use of
the product for other purposes. A sure sign of overload
products is melting or discoloration of parts due to the high
temperature, simultaneous failure of two or more nodes,
teaser on the surfaces of the cylinder and the piston or
destruction of piston rings. Also, the warranty does not
cover failure of the automatic voltage regulator due to
incorrect operation;
• Failure caused by clogging of the fuel and cooling systems;
• Wearing parts (carbon brushes, belts, rubber seals, oil
seals, shock absorbers, springs, clutches, spark plugs,
mufflers, nozzles, pulleys, guide rollers, cables, recoil starter,
chucks, collets, removable batteries, filters and safety
elements, grease, removable devices, equipment, knives,
drills, etc.);
• Electrical cables with mechanical and thermal damage;
• Product opened or repaired by a non-authorized service center.
• Prevention, care products (cleaning, washing, lubrication,
etc.), installation and configuration of the product;
• Natural wear products (production share);
• Failures caused by using the product for the needs related
to business activities;
• If the warranty card is empty or missing seal (stamp) of the Seller;
• The absence of the holder's signature on the warranty card.
WARRANTY CARD
The product is in good conditions and fully complete. Read and agree the terms of the warranty.
Product
Model
Company
Date
of sale
Product
Model
Company
Date
of sale

www.daewoopowerproducts.com
Manufactured under license of Daewoo International Corporation, Korea
Table of contents
Other Daewoo Switch manuals
Popular Switch manuals by other brands

IPGARD
IPGARD SA-DVN-1S-P quick start guide

Roland
Roland R-09HR Guide

Cabletron Systems
Cabletron Systems SEHI-22 user guide

ZyXEL Communications
ZyXEL Communications GS1910 user guide

Lutron Electronics
Lutron Electronics Maestro MS-B202 installation guide

Ruijie
Ruijie RG-CS86-20XS Series Hardware installation and reference guide

Digital Equipment
Digital Equipment VNswitch 900EE Installation and configuration

Lancom
Lancom GS-2326+ installation guide

Novus
Novus NV-208S/P+ user manual

Garmin
Garmin BLUENET 20 installation instructions

Gefen
Gefen 2x4 HDMI Switcher/Splitter user manual

Digitus professional
Digitus professional DN-80114 manual