This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibility
of the installer. The manufacturer assumes no responsibility
for equipment installed in violation of any codes or regulations.
Rated performance is achieved after 20 hours of operation.
Rated performance is delivered at the specied airow. See
outdoor unit specication sheet for split system models or
product specication sheet for packaged and light commercial
models. Specication sheets can be found at www.daikincom-
fort.com for Daikin products. Within the website, please select
the residential or commercial products menu and then select
the submenu for the type of product to be installed, such as air
conditioners or heat pumps, to access a list of product pages
that each contain links to that model’s specication sheet.
Should you
have any questions please contact the local oce of the EPA.
If replacing a condensing unit, heat pump or air handler, the
system must be manufacturer approved and Air Conditioning,
Heating and Refrigeration Institute (AHRI) matched.
The installation of an inverter heat pump with un-
matched system units will not allow for proper operation.
I
IS
.
NOTICE
Outdoor inverter units are approved for operation above 0°F
in cooling mode and -20°F (RH10%) in heating mode with no
additional kit necessary.
Damage resulting from operation of the unit in a structure
that is not complete (either as part of new construction or
renovation) is not covered by our warranties.
This heat pump is part of a system that uses inverter tech-
nology to more eciently remove or add heat with better
eciency and achieve the target comfort conditions. System
may ONLY be installed using a Daikin communicating ther-
mostat. The communicating system reduces the number of
required thermostat wires, provides additional setup features
and enhanced active diagnostics. Due to components using
inverter technology, the heat pump will not function properly
if used with a non-approved thermostat.
.
ONE
NOTICE
Special consideration must be given to location of the heat
pump unit(s) in regard to structures, obstructions, other units,
and any/all other factors that may interfere with air circulation.
Where possible, the top of the unit should be completely un-
obstructed; however, if vertical conditions require placement
beneath an obstruction
The specied dimensions meet requirements for air circulation
only. Consult all appropriate regulatory codes prior to deter-
mining nal clearances.
Another important consideration in selecting a location for the
unit(s) is the angle to obstructions. Either side adjacent the
valves can be placed toward the structure provided the side
away from the structure maintains minimum service clearance.
Corner installations are strongly discouraged.
OK!
OK!
AA AAA
A
CC
CC
OK!
OK!
OK!
OK!
NOT
AA
AA AA
AA
AA
B B B
B
A B C AA
10" 10" 18" 20"
12" 12" 18" 24"
This unit can be located at ground oor level or on at roofs.
At ground oor level, the unit must be on a solid, level foun-
dation that will not shift or settle. To reduce the possibility
of sound transmission, the foundation slab should not be in
contact with or be an integral part of the building foundation.
Care should be taken to ensure the unit is installed away
from noise sensitive locations such as bedrooms, windows
and outdoor living areas. Ensure the foundation is sucient
to support the unit. A concrete slab raised above ground level
provides a suitable base.
If it is necessary to install this unit on a roof structure, ensure
the roof structure can support the weight and that proper
consideration is given to the weather-tight integrity of the roof.
Since the unit can vibrate during operation, sound vibration
transmission should be considered when installing the unit.
Vibration absorbing pads or springs can be installed between
the heat pump unit legs or frame and the roof mounting as-
sembly to reduce noise vibration.