Daikin QTRON STARLITE User manual

Security
&
Home Automation System
QTRON STARLITE
USER MANUAL
(REVISION 1.2)

QTRON Starlite User Manual Rev 1.2

QTRON Starlite User Manual Rev 1.2
i
TABLE OF CONTENTS
PREFACE
TESTING
LIMITATIONS
FEATURES
QTRON STARLITE SYSTEM KEYPAD OVERVIEW
I ) SUMMARY OF KEYPAD OPERATION
II ) ARMING MODE
III ) SOUND INDICATION
IV) LIGHT INDICATION
V ) KEYPAD NAVIGATION KEY FUNCTION
CHAPTER 1: ALARM SYSTEM OPERATION
CHAPTER 2:TELEPHONY CONTROL FLOW (With Voice)
2.1 TELEPHONY CONTROL FLOW (BEEPER)
2.2 SYSTEM ALEART TO USER THROUGH TELEPHONE
CHAPTER 3: USER PROGRAMMING
3.1EDIT CONTROL CODE
3.1.1 CHANGE MASTER PIN
3.1.2 ADD/CHANGE USER PIN
3.2CHANGE DURESS PIN
3.3SYSTEM’S TIME
3.4 TIMER SETTING
3.4.1AUTO ARM TIMER
3.4.2AUTO DISARM TIMER
3.4.3 AUTOMATION (I/O) ON TIMER
3.4.4AUTOMATION(I/O) OFF TIMER
1
1
1
2
3
3
4
4
5
5
6
7
8
9
10
10
10
11
11
11
12
12
12
12
13

QTRON Starlite User Manual Rev 1.2
ii
3.5 TELEPHONE NUMBER
CHAPTER 4: KEYPAD SETTINGS
CHAPTER 5: SYSTEM CHECKING
5.0 CHECK FOR SYSTEM TROUBLE
5.1 TAMPERED AND PHONE LINE LOSS ALARM INDICATION
5.2 SYSTEM TESTING
5.2.1 WALK TEST
5.2.2 CMS TEST
5.2.3 SIREN TEST
5.2.4 STROBE LIGHT TEST
5.2.5 BATTERY TEST
GLOSSARY
SYSTEM INFORMATION
13
14
15
15
15
16
16
16
16
16
16
17
18

QTRON Starlite User Manual Rev 1.2
1
PREFACE
Thank you for choosing the Qtron Starlite Security and Home Automation system. High
quality, large number of functions and yet simple operation are main advantages of the system.
Hoping that you will be fully satisfied with this choice, we ensure you with our professional
assistance and information on our products.
This manual will explain to you on how to operate your Qtron Starlite security and home
automation system. This system is made up of a control panel, keypads, IO expander module
(optional), telephone voice module (optional), various sensors and detectors. An enclosure will
contain the control panel, which includes the system electronics and standby battery.
TESTING
It is advisable to perform periodical test of the alarm system –check every single detector’s
ability to detect zone violation by opening the protected windows, doors etc. It is also advisable
to check sirens and telephone voice messaging system. Please refer to testing procedures
section in this manual. If your system does not function properly, please contact your system
installer for services.
LIMITATIONS
Even though Qtron Starlite is an advanced security system, it does not 100% guarantee
protections against burglary, fire or other losses. Any alarm system whether commercial or
residential is subject to compromise or failure-to-warn for a variety of reasons. These include:
Intruders may gain access through unprotected openings or have the technical
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors, smoke detectors and many sensing devices will not operate without
power. Devices powered by AC will not work if there is no AC power supply for any
reason and their back up batteries are missing, dead or improperly installed.
Alarm warning devices such as sirens or bells may not alert people or wake up sleeper if
they are located on the other side of closed or partly closed door.
Telephone lines needed to transmit alarm from the premise to a central monitoring
station may be out or temporarily out of service. Telephone station lines are subjected to
compromise by sophisticated method of attack.
Smoke detector used in conjunction with the alarm system may not sense fires that start
where smoke cannot reach the detector such as wall, roof or the other side of the door.
Smoke detector also may not sense a fire on another level of residence or carelessness
and safety hazards like smoking in the bed, violent explosions, escaping gas, improper
storage of flammable material, overloaded electrical circuits, and children playing with
matches.
The most common cause of an alarm system not functioning properly when an intrusion
or fire occurs is inadequate maintenance. Therefore, your system should be tested
weekly to ensure all sensors are working properly.
Installing an alarm system may make you eligible for lower insurance rates but an alarm
system is not substitute for insurance. Homeowners, property owners and renters should
continue to insure their lives and properties.

QTRON Starlite User Manual Rev 1.2
2
FEATURES
1. 8 fully programmable zones
2. Expandable up to 8 output controls (with feedback capability)
3. Keypad lockable.
4. 1 Real time ARM/DISARM timer on Daily Basis only.
5. 2 Real time ON/OFF timer on daily basis
6. 1 Master pin & 7 User pin
7. 3 Soft Zones (Emergency/Fire/Panic)
8. 2 Programming Mode- Installer Programming and User Programming
9. 4 User Arming type (Auto home arming/ Day arming/ Night arming/ Force arming)
10. Real time clock function
11. Programmable Entry/Exit Delay Time
12. 4 bell types (Steady/ Pulse/ Chirp/ Silent)
13. 3 zone types [End-of-line (EOL) / Normally Open (NO) / Normally Close (NC)]
14. Adjustable loop response sensitivity
15. Key Switch function (Latch/ Momentary)
16. Dedicated Tamper zone
17. AC power supply monitoring
18. Low battery indication
19. Bell Test & Walk Test function
20. Telephone line loss detection
21. Telephone Voice Module
22. RS485 ready (to support longer distance communication)
23. Report events to 4 phone numbers with 4 account numbers
24. Ademco® Contact ID CMS reporting format
25. Voice reporting format (direct to user) or tone reporting format
26. Interactive Voice menu or tone beepers during user call in
27. Support Remote programming via touch tone telephone
28. 8 Programmable Event Trigger Output
29. Fast Key on Keypad for Easy menu access
30. 1 Duress pin
31. Double Call-in Feature for Fax Machine telephone line sharing

QTRON Starlite User Manual Rev 1.2
3
QTRON Starlite SYSTEM KEYPAD OVERVIEW
SUMMARY OF KEYPAD OPERATION
Key
Fast Key (Press & hold for 2s)
Description
1
AUTO
AUTO HOME Arming
2
DAY
DAY Arming
3
NIGHT
NIGHT Arming
4
FORCE
FORCE Arming
5
AUTOMATION
AUTOMATION menu
6
MEMORY
VIEW ALARM MEMORY menu
7
CHIME
CHIME menu
8
SERVICE
SERVICE menu
9
BYPASS
BYPASS menu
F
FIRE
FIRE ALARM
E
EMERGENCY
EMERGENCY ALARM
P
PANIC
PANIC ALARM
Key
Key Description
Description
*
CANCEL
Clear the pin number on main menu.
Exit automation/ memory/ chime/ service/ bypass mode.
#
ENTER
Confirm input/ setting/ pin.
COM
COMMAND
Enter User / Installer programming mode.

QTRON Starlite User Manual Rev 1.2
4
ARMING MODE TYPES
Arming Type
Information
When To Use
Auto home Arming
To arm the system with Exit delay
countdown in order for the user to exit the
house.
The interior zones are not bypassed.
When user leaves the house
and no one is at home.
System still able to arm
when interior zone and delay
zone are open.
Day Arming
The perimeter zone is armed instantly
while the user stays at home.
The interior zones are automatically
bypassed.
When user is at home.
Night Arming
The perimeter zone is armed instantly
while user stays at home.
The interior zones are automatically
bypassed and the delay zones become
instant zone.
When everyone come back
to home & user want to
sleep.
Force Arming
To force arm the system with Exit delay
count down in order for the user to exit
the house.
The interior zones are not bypassed.
When there are zones faulty.
SOUND INDICATION
Sound Indication
Description
Acceptance / Acknowledgement tone
2 fast beeps
Error tone
Long beeps
Entry delay
Continuous slow beep, fast beep for the last 10 sec
Exit delay
Continuous slow beep, fast beep for the last 10 sec
Zone’s chime
Continuous tone for about 2 seconds
Alarm
Chirp (1 second ON/ 4 seconds OFF)
Pulse (2 seconds ON/ 2 seconds OFF)
Continuous Tone
Silent

QTRON Starlite User Manual Rev 1.2
5
LIGHT INDICATION
QTRON Starlite Keypad Display’s Reference Table
NOTE:
* : When AC power ON, LED is ON; When AC power failure, LED is OFF
** : When armed, LED = ON
When Emergency/Fire/Panic, LED = Flash
When disarmed, LED = OFF
*** : When trouble occurs, LED is ON; when no trouble occurs, LED is OFF
**** : When alarm gets trigged, the LED is ON
When alarm memory has been clear or didn’t trigged, LED is OFF
Flash : 0.5 second ON, 0.5 second OFF
Fast flash : 0.1 second ON, 0.1 second OFF
No
Description
PWR
ARM
SER
KEY
MEM
Zones
1
Normal Mode
*
OFF
***
OFF
****
Zone status
2
Arming
*
ON
***
OFF
****
Zone status
3
Home Automation
Mode
Flash
OFF
Flash
OFF
OFF
IO status
4
User Programming
Mode
OFF
Flash
Flash
Flash
Flash
-
5
AC power failure
OFF
**
ON
OFF
****
-
6
Service status
*
**
ON
OFF
****
-
7
View Service
Mode
*
**
Flash
OFF
****
ON according to
the type of trouble
(refer to table
below)
8
Zone’s Status
(Opened)
(Bypassed)
(Alarmed)
*
*
*
**
**
**
***
***
***
OFF
OFF
OFF
****
****
****
ON
Flash
Fast flash
9
Tamper zone
triggered
*
Fast
flash
***
OFF
****
All zone’s LEDs
Fast flash
10
Telephone line
loss alarm
triggered
*
Fast
flash
Fast
flash
OFF
****
-
11
Walk test
Flash
OFF
OFF
Flash
Flash
Flash zone that is
triggered/ open.
12
Keypad locked
*
OFF
***
ON
****
-

QTRON Starlite User Manual Rev 1.2
6
CHAPTER 1: ALARM SYSTEM OPERATION
Security System Operation
AUTO HOME ARM
Press and hold [1] for 2 second or Press [Pin] + [#]
DAY ARM
Press and hold [2] for 2 second
NIGHT ARM
Press and hold [3] for 2 second
FORCE ARM
Press and hold [4] for 2 second
DISARM
Press [Pin] + [#]
ON/OFF AUTOMATION
Press and hold [5] for 2 second + [1 to 8] + [#]
VIEW ALARM MEMORY
Press and hold [6] for 2 second
PROGRAM CHIME ZONE
Press and hold [7] for 2 second
VIEW SERVICE MODE
Press and hold [8] for 2 second
BYPASS ZONE
Press and hold [9] for 2 second + Zone [1 to 8] + [#]
FIRE ALARM
Press and hold [F]for 2 second
EMERGENCY ALARM
Press and hold [E]for 2 second
PANIC ALARM
Press and hold [P]for 2 second
Default Master Pin: 1234
Remark:
* Each time the alarm system is disarmed; all the bypassed zone will be unbypassed.
Press [4 digits Master CODE]
[COM] [0] [#]

QTRON Starlite User Manual Rev 1.2
7
CHAPTER 2:TELEPHONY CONTROL FLOW (With Voice)
Remarks:
(i) For Automation Menu, if key ‘00’ is pressed,
system will OFF ALL outputs if any of the IO is
ON; else system will process as ON ALL.
(ii) The system will automatically cut off telephone
line if user does not key in any number for more
than 60 seconds or key in wrong master pin more
than 3 times
[1]Force Arm/ Disarm System
Slow
beeps
[#] Voice Menu:
“Press
1 for Security Menu;
2 for System Status;
3 for Siren Control;
4 for Zone Bypass & Restore Menu;
5 for Automation Menu;
Press 0 for Exit; “
[3] ON/ OFF Siren
[4]Zone
Bypass/Byp
ass Restore
[01] to [08]
(Zone
Number)
[*] to exit
[2] System Status Report On:
- System Arm/Disarm
- Alarm Triggered Zone
- Zone Open / Bypassed
- Siren ON / OFF
- Output ON / OFF
- DC / Siren/ AC Status (if
system status enabled)
- Fire / Emergency/ Panic
alarmed
[5] On / Off
Automation
Output
[01] to [08]
(Output
Number)
[00] to
ON/OFF
All
[*] to exit
Answer
Call
System Voice
Report and Voice
Guidance
Press any
key
[0] to [9]
[0] End telephony control
Dial
Phone
Number
Wait for
system
answer
System
Welcome
Note and
Voice
Guidance
[Master
PIN] +
[#]
System Call Out:
Call In to System:
[*]
[*]
[Master
PIN] +
[#]

QTRON Starlite User Manual Rev 1.2
8
2.1 TELEPHONY CONTROL FLOW (BEEPER)
System Call Out:
Call In to System:
Remarks:
(i) For Alarm Report, system will beep base
on the alarmed zone number, e.g.,
Zone 2 alarm - “Beep…Beep”
Zone 3 alarm-“Beep….Beep…..Beep”
(ii) If Fire/Emergency/Panic or Tamper
alarm, system will play continuous 6
beeps.
Acceptance Tone
(Short Beep)
OR
Error/ Reject Tone
(Long Beep)
(Continuous tone for Alarm;
OR
5 beep tone for Arm/Disarm/
Zone Restore/ Trouble)
Answer
Call
Slow
beeps
Press any
key
[0] –[9]
Alarm/
Event
Tone
To Force Arm System
[1] + [0] + [#]
To Disarm System
[2] + [0] + [#]
To Check Alarm report
[3] + [#]
*For next alarm, press [#]
again
To ON Siren
[4] + [#]
To OFF Siren
[5] + [#]
To Bypass Zone
[6] + [Zone Number 01 - 08] + [#]
To Restore Bypass Zone
[7] + [Zone Number 01 - 08] + [#]
To ON Automation output:
[8] + [Output Number 00 - 08] + [#]
To OFF Automation output:
[9] + [Output Number 00 - 08] + [#]
Dial
Phone
Number
Wait for
system
answer
[Master
PIN] +
[#]
To End Telephony control:
[0] + [#]
[Master
PIN] +
[#]
Acceptance
Beeper
Tone
Acceptance
Beeper
Tone

QTRON Starlite User Manual Rev 1.2
9
2.2 SYSTEM ALERT TO USER THROUGH TELEPHONE
In case of any intrusion or emergency, this system will acknowledge users with an alarm report.
The panel will contact the user through fixed telephone or mobile line. If the user is unable to
reply the phone call, this system will call the user again. The default dial attempts are 5 times.
After 30 minutes, the system will call again. The number of repetition calls after 30 minutes
depend on the redial attempt set in the installer programming. The reporting comes in two
reporting condition –no voice or beeper reporting and voice reporting (if voice module is
installed).
System will report the status of the system to user when an event happened accordingly to the
list below:
Reporting Through Telephone
Description
Zone X Violated
Zone X has been violated
Zone X Restored
Alarm in zone X has been restored
Emergency
Emergency button had been pressed
Fire
Fire button had been pressed
Panic
Panic button had been pressed
Help
Duress Pin has been entered
AC Loss
AC loss detected
AC Restore
AC power had been restored
DC Loss
DC loss detected
Zone X Bypass
Zone X has been bypassed
Zone X Bypass Restore
Zone X has been un-bypassed
Tamper
System Tampered has been detected
System Armed
System has been armed
System Disarmed
System has been disarmed

QTRON Starlite User Manual Rev 1.2
10
CHAPTER 3: USER PROGRAMMING
User programming can only be access when the alarm system is under disarmed or no alarm
condition. To enter user programming mode, press [COM][Pin][#]. The default Master Pin is
1234. User is advice to change the Master pin once the alarm system had been handover.
To exit the programming mode, press [COM] [#].
USER PROGRAMMING SUMMARY
CHANGE MASTER PIN
Press [01]+[4 Digit New Pin]+[New Pin]+[#]
ADD/CHANGE USER PIN
Press [02-08]+[4 Digit New Pin]+[New Pin]+[#]
(can set up to maximum 7 users pin 02,03,04,05,06,07,08)
CHANGE DURESS PIN
Press [09]+[4 Digit New Pin]+[New Pin]+[#]
EDIT SYSTEM’S TIME
Press [10]+[Current Time 24 Hour Format]+[#]
AUTO ARM TIMER
Press [11]+[Auto Arm Timer]+[#]
AUTO DISARM TIMER
Press [12]+[Auto Disarm Timer]+[#]
ON IO TIMER 1
Press [13]+[Auto On Timer 1]+[#]
OFF IO TIMER 1
Press [14]+[Auto Off Timer 1]+[#]
ON IO TIMER 2
Press [15]+[Auto On Timer 2]+[#]
OFF IO TIMER 2
Press [16]+[Auto Off Timer 2]+[#]
TELEPHONE NUMBER 1
Press [17]+[Phone Number 1]+[#]
TELEPHONE NUMBER 2
Press [18]+[Phone Number 1]+[#]
TELEPHONE NUMBER 3
Press [19]+[Phone Number 1]+[#]
TELEPHONE NUMBER 4
Press [20]+[Phone Number 1]+[#]
3.1 EDIT CONTROL CODE
3.1.1 CHANGE MASTER PIN
Command
Information
Press 01 then enter the 4 digits new pin then re-enter
the same pin again and press # after done.
The keypad will sound 2 fast beeps after
pressing 01, then keypad will sound another 2
fast beeps after entering the new pin twice.
Note:
The Code “0000” is not allowed to be used as a pin , Master Code default value: “1234”
Press [4 digits Master CODE]
[COM] [0] [#]

QTRON Starlite User Manual Rev 1.2
11
3.1.2 ADD/CHANGE USER PIN
Command
Information
Press the user number (02-08) then enter the 4 digits
new pin then re-enter the same pin again and press #
after done.
The keypad will sound 2 fast beeps after
pressing 02-08, then keypad will sound
another 2 fast beeps after entering the new
pin twice.
To delete the user pin, press user number [02-08] then
press 0000 twice and #.
[02-08]+[0000]+[0000]+[#]
The keypad will sound 2 fast beeps after
pressing 02-08, then keypad will sound
another 2 fast beeps after deleted the user
pin.
Note:
The Code “0000” is not allowed to be used as password.
User pin can only arm & unarm, in away arm mode.
3.2 CHANGE DURESS PIN
Note:
-Duress Code default value: “2222”
3.3 SYSTEM’S TIME
This allow user to edit the time of the system.
Command
Information
Press 10 then set the current time in 24 hour
format and press # after done.
The keypad will sound 2 fast beeps after pressing
10, then keypad will sound another 2 fast beeps
after the new time was set.
Command
Information
Press 09 then enter the 4 digits new pin then re-
enter the same pin again and press # after done.
The keypad will sound 2 fast beeps after
pressing 09, then keypad will sound another
2 fast beeps after entering the new pin
twice.
To delete the duress pin, press 09 then press 0000
twice and #.
[09]+[0000]+[0000]+[#]
The keypad will sound 2 fast beeps after
pressing 09, then keypad will sound another
2 fast beeps after delete the duress pin.

QTRON Starlite User Manual Rev 1.2
12
3.4 TIMER SETTING
3.4.1 AUTO ARM TIMER
This allow user to set timer to auto Arm the system.
Command
Information
Press 11 then set the auto arm timer in 24
hour format and press # after done.
The keypad will sound 2 fast beeps after pressing
11, then keypad will sound another 2 fast beeps
after the auto arm timer was set.
To delete the timer, press 11 then #.
[11]+[#]
The keypad will sound 2 fast beeps after pressing
11, then keypad will sound another 2 fast beeps
after delete the timer.
3.4.2 AUTO DISARM TIMER
This allow user to set timer to auto Disarm the system.
Command
Information
Press 12 then set the auto disarm timer in 24
hour format and press # after done.
The keypad will sound 2 fast beeps after pressing
12, then keypad will sound another 2 fast beeps
after the auto disarm timer was set.
To delete the timer, press 12 then #.
[12]+[#]
The keypad will sound 2 fast beeps after pressing
12, then keypad will sound another 2 fast beeps
after delete the timer.
3.4.3 AUTOMATION (I/O) ON TIMER
It is to set the timer to turn ON the outputs automatically.
Command
Information
Press 13 then set the timer 1 to turn on the
outputs in 24 hour format and press # after
done.
The keypad will sound 2 fast beeps after
pressing 13, then keypad will sound another 2
fast beeps after the IO on timer 1 was set.
Press 15 then set the timer 2 to turn on the
outputs in 24 hour format and press # after
done. : [Timer number] [#] : [ ] [ ] [ ] [ ] [#]
The keypad will sound 2 fast beeps after
pressing 15, then keypad will sound another 2
fast beeps after the IO on timer 2 was set.
To delete the timer, press 13/15 then #.
[13/15]+[#]
The keypad will sound 2 fast beeps after
pressing 13/15, then keypad will sound
another 2 fast beeps after delete the timer.

QTRON Starlite User Manual Rev 1.2
13
3.4.4 AUTOMATION (I/O) OFF TIMER
It is to set the timer to turn OFF the outputs automatically.
3.5 TELEPHONE NUMBER
It is to set the telephone number that the main system is going to dial and communicate
with using CMS system.
Command
Information
Press 14 then set the timer 1 to turn off the
outputs in 24 hour format and press # after
done.
The keypad will sound 2 fast beeps after pressing
14, then keypad will sound another 2 fast beeps
after the IO off timer 1 was set.
Press 16 then set the timer 1 to turn off the
outputs in 24 hour format and press # after
done. : [Timer number] [#] : [ ] [ ] [ ] [ ] [#]
The keypad will sound 2 fast beeps after pressing
16, then keypad will sound another 2 fast beeps
after the IO off timer 2 was set.
To delete the timer, press 14/16 then #.
[14/16]+[#]
The keypad will sound 2 fast beeps after pressing
14/16, then keypad will sound another 2 fast
beeps after delete the timer.
Command
Information
Press 17 then set the telephone number 1 for
CMS system.
The keypad will sound 2 fast beeps after pressing
17, then keypad will sound another 2 fast beeps
after the telephone number 1 was set.
Press 18 then set the telephone number 2 for
CMS system. : [Timer number] [#] : [ ] [ ] [ ] [ ] [#]
The keypad will sound 2 fast beeps after pressing
18, then keypad will sound another 2 fast beeps
after the telephone number 2 was set.
Press 19 then set the telephone number 3 for
CMS system.
The keypad will sound 2 fast beeps after pressing
19, then keypad will sound another 2 fast beeps
after the telephone number 3 was set.
Press 20 then set the telephone number 4 for
CMS system.
The keypad will sound 2 fast beeps after pressing
20, then keypad will sound another 2 fast beeps
after the telephone number 4 was set.
To delete the telephone number, press
17/18/19/20 then #.
[17/18/19/20]+[#]
The keypad will sound 2 fast beeps after pressing
17/18/19/20, then keypad will sound another 2
fast beeps after delete the timer.

QTRON Starlite User Manual Rev 1.2
14
CHAPTER 4: KEYPAD SETTINGS
In order to access to the keypad setting, the system must enter user programming mode. The
following are the keypad setting’s functions and how to change the setting.
Note:
Default keypad setting will be all toggling ON (Enable).
Keypad will beep twice for valid entry.
The keypad setting change is only applied to that individual keypad.
Remark:
Keypad Back Light–The light which light up the keypad button area.
Entry & Exit Delay Buzzer Sound- The beeps sound during entry and exit delay.
Lock/Unlock Keypad- A function that prevent stranger interrupt the system.
Functions
Command
Information
Keypad
Backlight
Press [COM]+[6]+[#]
This operation will toggle the keypad back light to
ON/OFF.
ENTRY & EXIT
DELAY
BUZZER
SOUND
Press [COM]+[7]+[#]
This operation will toggle the entry and exit delay
buzzer to ON/OFF.
LOCK/UNLOCK
KEYPAD
Press [COM]+[8]+[#]
This operation will toggle the keypad to
LOCK/UNLOCK.

QTRON Starlite User Manual Rev 1.2
15
CHAPTER 5: SYSTEM CHECKING
5.0 SERVICE CHECK
System must be in normal or armed mode in order to view trouble. Control panel will monitor a
number of possible trouble conditions. If one of these conditions occurs, the SERVICE light
will turn ON and remain ON until trouble free and/or it receives clearance instruction from the
users. There are only 6 conditions available designated by indication lights (1 to 8, indication
light 2&5 will remain OFF all the time).
Command
Information
To view the service condition:
Press [8] and hold for 2 sec
The service light will OFF to indicate that keypad is under
View Service Mode.
Designated zone light is used to reflect the type of problem.
(Refer to table below)
To Exit View Trouble mode
Press [#]
The service light will be ON if the trouble conditions still
remain.
The designated zone light will be restored back to the actual
zone’s status.
The following are the system service indication represented by the Zone’s LED:
5.1 TAMPEREDANDPHONELINE LOSS ALARM INDICATION
Reporting / Zone indication
Description
Tampered Alarm
ARMED and all zone LED will fast Blinkto indicate the
alarm was triggered by the tamper switch.
Phone Line Loss Alarm
ARMED and SERVICE LED will fast Blink to indicate the
alarm was triggered by the phone line loss.
Display
Trouble
Causes
Zone1 LED turn ON
AC Loss
No power supply detected
Zone 4 LED turn ON
DC Loss (Low Battery)
Backup battery in weak or backup battery is not
available.
Zone 6 LED turn ON
External
Communication Error
Unable to call out either due to no reply by user
during reporting.
Zone 7 LED turn ON
Phone Line Loss
No phone line connected to the system.
Zone 8 LED turn ON
Tamper
Tamper occurred and has not been cleared by
alarm memory clear.

QTRON Starlite User Manual Rev 1.2
16
5.2 SYSTEM TESTING
Users are advised to test the system frequently. System must be tested at least once every three
months. If the system is not functioning accordingly, please contact the nearest dealer for
technical assistance. In order to test the alarm system, system must be on normal mode. There
are5types of tests: walk test, cms test, siren test, strobe light test and battery test.
5.2.1 WALK TEST
Command
Information
Initiate Walk Test
Press [COM]+[1]+[#]
Walk test allow on-site testing for each zone of the system
The keypad will beep twice upon confirmation
The PWR, KEY and MEM light will FLASH to indicate that
the system is currently under the Walk Test.
Each time zone faulted, corresponding zone light will fast
flash and keypad will chime until system exit walk test.
To exit, press [#] key.
The keypad will beep twice upon confirmation. Back to
normal mode.
5.2.2 CMS TEST
Command
Information
Manual test reporting for CMS
Press [COM] +[2]+[#]
The keypad will beep twice upon confirmation. Panel will
generate message to CMS center.
5.2.3 SIREN TEST
Command
Information
Test siren
Press [COM]+[3]+[#]
Once command has been acknowledged, the keypad and bell
will sound continuously for 3 seconds.
5.2.4 STROBE LIGHT TEST
Command
Information
Test strobe light
Press [COM]+[4]+[#]
Once command has been acknowledged, the strobe light will
on continuously for 3 seconds.
5.2.5 BATTERY TEST
Command
Information
Test back-up battery
Press [COM]+[5]+[#]
Battery test takes few seconds
The keypad will beep twice or reject toneas a result.
The indication of low battery can be seen from View System
Service Mode.
Table of contents
Other Daikin Home Automation manuals
Popular Home Automation manuals by other brands

weinor
weinor WeiTronic Combio-868 MA Operating and installation instructions

SPARKELEC
SPARKELEC Zigbee Touch Smart Switches Series instructions

IntesisHome
IntesisHome PA-AW-WIFI-1 installation guide

netelec
netelec HUB15B-PIR user manuel

Clare Controls
Clare Controls ClareOne CLR-C1-PNL1 Release notes

urmet domus