Daitsu GT Series User manual

USER MANUAL
Édition
06/23
PASARELA DE GESTIÓN
REMOTA ACCD_GT3
Série
Intelligent Remote Controller GT

To Users
Thank you for selecting this product. Before installing the product, please
read this instruction manual carefully to know well about the product and use it
correctly. In order to install and use the product correctly to reach the expected
operational effect, the following instructions are hereby issued:
(1) The appliance is not intended to be used by the people with physical,
sensory or mental handicap or the people without using experience and
knowledge (including children), except that they are supervised or guided
by a person responsible for their safety when using the appliance.
Children should be supervised to ensure that they do not play with the
appliance.
(2) In order to ensure the reliability of product, the unit will consume a little
power under standby status to maintain normal communication of system
and preheating of refrigerant and lubrication. If the product is not used for
a long time, please cut off the power supply; preheat the unit before
reusing it.
(3) Please select the model according to actual using environment, otherwise
it may impact the using comfort.
(4) This product has passed strict inspection and operational tests. In order to
prevent damage of unit or impact of normal operation due to improper
disassembly and inspection, users are not allowed to disassemble the unit
by themselves. Please contact our special maintenance center and
operate under the guidance of our personnel if necessary.
(5) We will bear no responsibility for the personal injury, property loss or
damage of equipment due to improper installation and debugging,
unnecessary maintenance, non-observance of related national laws,
regulations, and industrial standards, violation of any stipulations of this
instruction manual, etc.
(6) When the product is faulted and cannot work, please contact our special
maintenance center according to the following points.
1)Content in nameplate of product (model, cooling/heating capacity,
product code, ex-factory date).
2)Error status (specifically elaborate the situation after the error occurs).

(7) All the illustrations and information in the instruction manual are only for
reference. In order to better meet the customers’ demand, our company
will improve the product continuously and we have the right to conduct
necessary modification at anytime due to the reason of sales or
production, and will reserve the right of modification without further
notification.

Contents
1 Safety Notices (please do abide by it)................................................1
2 User Notices.......................................................................................1
3 Functions and Parameters .................................................................3
3.1 Outline of Functions.....................................................................3
3.2 Instruction of Parameters.............................................................3
4 Integral Components ..........................................................................3
5 Detailed Introduction to Controller......................................................4
5.1 Ports ............................................................................................4
5.2 LED Display.................................................................................6
5.3 Dial Code.....................................................................................7
6 Applicable Location ............................................................................9
6.1 Intelligent Remote Eudemon System................................10
6.2 Network Topology ......................................................................10
7 Product Installation...........................................................................12
7.1 Product Dimension and Installing Space Dimension of Electric
Control Cabinet................................................................................12
7.2 Communication Connection.......................................................13
7.3 Connection of Controller DO Port and Device ...........................22
Attachment A Address of Dial Code..................................................23
Attachment B For the Applicable Models of this Intelligent Remote
Controller ............................................................................................27
Attachment C TCP/IP Setting..............................................................28

Intelligent Remote Controller
1
1 Safety Notices (please do abide by it)
Warning: please abide by it strictly, otherwise it may cause severe damage
to the unit or personal casualty.
Caution: please abide by it strictly, otherwist it may cause light or medium
damage to the unit or personal casualty.
It refers to the behavior that must be forbidden! Otherwise it may cause
personal casualty or severe damage.
It refers to the behavior that must be abided by! Otherwise it may cause
personal injury or property damage.
Warning!
This product cannot be installed in the corruptive or flammable environment or
the place with oil or frog (such as kitchen), otherwise the unit cannot work normally
or it may shorten the service life of unit, or even cause fire or severe damage. The
aforesaid location is suitable to be installed with anti-corruptive or anti-explosive
product.
2 User Notices
Distinguished users:
Before installing or using this appliance, please read this instruction manual
carefully, and install and use according to the process stipulated in the instruction
manual.
Warning!
(1)It should be installed by professional personnel, improper installation may
cause fire or electric shock.
(2)Insert the socket only after ensuring the socket of power cord is dry and
clean.
(3)Before touching the electric components, please make sure that the
appliance is power-failed.
(4)Please do not touch this appliance with wet hands, which may cause electric
shock.
(5)Please use the power cord with designated specification; poor contact or
improper installation may cause fire hazard.
(6)Reverse connection of power cord or improper input power range may cause
fire hazard or damage the appliance.
(7)For the equipment with power plug, the power socket should be installed near
the equipment for convenient using.

Intelligent Remote Controller
2
(8)Please do install the appliance inside the inapproachable and locked
electric control cabinet indoors.
(9)Please install this appliance in the place where is without interference of
electromagnetic wave or dust.
Caution!
(1)Please ensure the specification of the input power supply, otherwise this
appliance may cannot work normally or even be damaged.
(2)Please make sure that the equipment is installed in the correct position,
otherwise it may cause communication error.
(3)Make sure that the communication wire is connected into the correct
interface, otherwise it may cause communication error.
(4)After connecting the wires, please use insulated adhesive tape to protect the
wire to prevent oxidation or short circuit.
(5)There is explosion hazard if using wrong batteries, please dispose the waste
batteries according to the instruction.
(6)Requirements for normal working environment of Intelligent Remote
Controller:
①Temperature: -20~+60℃;
②Humidity: less than or equal to 85%;
③It should be installed indoors (it is recommended to install inside the
electric control cabinet) and prevent direct sunlight, rain, snow, etc.
(7)All the illustrations in the instruction manual are only for reference.
(8)After the Intelligent Remote Controller is energized, please wait for 6~8
minutes to make the communication between it and the Intelligent Remote
Eudemon system becomes stable, and then the software can monitor the units
normally.

Intelligent Remote Controller
3
3 Functions and Parameters
3.1 Outline of Functions
Intelligent Remote Controller(model:ACCD-GT3 works with
Intelligent Remote Eudemon system,can achieve monitor and control for the water
heater,U-Match and rooftop for using method of Intelligent Remote Eudemon
system please see the instruction manual of the software. Intelligent Remote
Controller has 5 DO ports (DO1, DO2, DO3, DO4, and DO5), User can define the
connection of supporting units of the water heater according to actual needs. (Only
applicable for commercial water heater),For example, as to the circulating pump,
user side water pump, auxiliary pipe electric heater and other connecting units, their
On/Off status can be controlled manually or automatically through the Intelligent
Remote Eudemon.
For the applicable models of this Intelligent Remote Controller, please refer to
Annex B.
3.2 Instruction of Parameters
3.2.1 Controller Default TCP/IP Parameters
IP address: 192.168.1.150;
Subnet mask: 255.255.255.0;
Default gateway: 192.168.1.1.
Caution: after the TCP/IP parameters are altered, the controller should be
re-energized, then can the altered parameters become valid.
3.2.2 Controller Mac
Controller Mac as the only identity of Intelligent Remote Eudemon system, it
can be viewed in the “Equipment Mac” parameters of configuration interface.
4 Integral Components
This appliance includes the following fittings. Please check before installation.
Intelligent Remote
Controller(ACCD-GT3) 1set
Instruction Manual
1pcs

Intelligent Remote Controller
4
5 Detailed Introduction to Controller
5.1 Ports
5.1.1 Sketch Map of Ports

Intelligent Remote Controller
5
5.1.2 Power Supply
Power input is 100VAC-240VAC, 50/60Hz.
Warning! The protective earthing wire in the power port must be connected,
otherwise it may cause hazard; moreover, when the controller is energized, please
do not touch the power input position.
Note:The power cord should pass through the wire-pressing clamp for fixing.
The power cord with the diameter of 3×1.0mm2is suggested to be used. As show
in the figure.
5.1.3 Communication Port
CAN communication port: this communication port isnot applicable to this
appliance yet.
RS485-1 communication port: connect to the device through two-core
communication wire, to achieve the communication between Intelligent Remote
Controller and MODBUS Protocol.
RS485-2 communication port: this communication port isnot applicable to
this appliance yet.
USB and SD card ports: these ports are not applicable to this application yet.
Ethernet port: this port is to achieve communication between cable wire and
Intelligent Remote Eudemon system.

Intelligent Remote Controller
6
5.1.4Digital Input/Output
DI1...DI5: not available.
DO1...DO5: to be connected with the supporting units of the water heater and used
together with Intelligent Remote Eudemon. They are used to realize auto or manual
start/stop (Only applicable for commercial water heater).
Relay output, normally-open contact, passive output; maximum capacity:
250VAC,3A; 30VDC,3A.
DO6: reserved.
5.2 LED Display
The LED indicators shown above are mainly divided into two parts: status
indicators (operation, alarm, power) and communication indicators (CAN, RS485,
RS2332). The following chart shows the working status of the indicators.

Intelligent Remote Controller
7
CAN RX This appliance does not adopt such LED display.
CAN TX This appliance does not adopt such LED display.
RS485-1 RX When Intelligent Remote Controller receives the data
of the connected device, it will blink.
RS485-1 TX
When Intelligent Remote Eudemon sends data to the
device connected with Intelligent Remote Controller,
it will blink.
RS232 RX This appliance does not adopt such LED display.
RS232 TX This appliance does not adopt such LED display.
RS485-2 RX This appliance does not adopt such LED display.
RS485-2 TX This appliance does not adopt such LED display.
Power
When power supply of Intelligent Remote Controller
is normal, it is constantly on.
Operation
When the Intelligent Remote Controller works
normally, it flashes.
Alarm This appliance does not adopt such LED display.
5.3 Dial Code
Caution! Before using this appliance, please set the dial code for it, otherwise
it cannot operate normally.
Controller dial code setting area consists of address dialer and function dialer.

Intelligent Remote Controller
8
5.3.1 Sketch Map of Dialer
HSBLSB
1 65432 7 8
0
1
is the location for dial-up button
Dial-up value in
this location is 0
Dial-up value in
this location is 1
5.3.2 Address Dialer——set the address for equipment
The address dialer is for setting the equipment address of Intelligent Remote
Controller.
Caution! Before using this controller, please set the address dialer of
controller first, and the dial code address of the same system network should not be
repeated.
Address setting range of Intelligent Remote Controller: 0~254. For specific dial
codes please refer to dial code address attachment A: dial code address.
Example for setting address:
Setting method for address 11 is shown as below:
1 65432 7 8
0
1
Address
Address
1 1 0 1 00
00 11
1 2 345678
value
DIP form
Setting method for address 43 is shown as below:
1 65
432 7 8
0
1
Address
Address
1 1 0 1 0010 43
1 2 3 45678
value
DIP form

Intelligent Remote Controller
9
5.3.3 Address dial code 8 bits –controller resumes to default
setting
When the network is not accessible due to website collocated IP address,
subnet mask, default gateway, equipment name, etc.of Intelligent Remote
Controller are wrong, please dial all the 8 bits address to 1, after all the indicators
(except power indicator) flash, resume the dial code and restart the controller, then
the ex-factory default information of controller is resumed.
HSBLSB
1 65432 7 8
0
1
Is the location for dial-up button.
5.3.4 The 7th bit of function dialer – MODBUS bus bar
matched resistance setting
The 7th bit of function dialer is used for the setting of MODBUS bus bar
matched resistance.
When the controller is needed to with matched resistance in MODBUS bus bar,
dial the switch to be with matched resistance.
Setting of dial code for matched resistance is as below:
7
with the
matched
resistance
not with the
matched
resistance
7
is the location for dial-up button
function
1 65432 7 8
0
1
0
1
6 Applicable Location
Applicable location of Intelligent Remote Controller is Intelligent Remote
Eudemon System.

Intelligent Remote Controller
10
6.1 Intelligent Remote Eudemon System
When adopting Intelligent Remote Eudemon System, this controller is
used to connect into Intelligent Remote Eudemon System to achieve monitor and
control of water heater, U-Match and rooftop unit via Intelligent Remote
Eudemon System. Intelligent Remote Eudemon system connects to Intelligent
Remote Controller through Ethernet. One Intelligent Remote Eudemon system can
connect to 16 Intelligent Remote Controller at most.
6.2 Network Topology
Network topology instructions of water heater:

Intelligent Remote Controller
11
L1: L1 shown in the figure is Ethernet.
L2: L2 shown in the figure is MODBUS bus bar, which consists of Intelligent
Remote Controller and wired controller of water heater. One MODBUS network can
connect to 16 wired controllers of water heaters at most.
L3: L3 shown in the figure is communication bus bar of unit, which consists of
wired controller of water heater and water heater. One unit network can connect to
16 sets of water heaters at most.
Connectable quantity of Intelligent Remote Controller: one Intelligent Remote
Controller can connect to 16 wired controllers of water heaters at most (that is, it
can connect to 256 sets of water heaters at most).
Network topology instructions of U-Match and rooftop unit:
L1:L1 shown in the figure is Ethernet.
L3:L3 shown in the figure is MODBUS bus bar, which consists of Intelligent
Remote Controller, U-Match and rooftop unit. One MODBUS network can connect
to 255 sets of U-Match or rooftop unit at most.

Intelligent Remote Controller
12
Note: L1 shown in the figure is standard cable wire, L2 and L3 is twisted pair.
7 Product Installation
7.1 Product Dimension and Installing Space
Dimension of Electric Control Cabinet
7.1.1 Product Dimension
L×W×H: 266×208×59(mm)
7.1.2 Installing Space of Electric Control Cabinet
Intelligent Remote Controller should be installed in the electric control cabinet,
and the controller is hanged with the front face upward, and then use 4 screws to fix.
The needed space is shown as below (only for reference).

Intelligent Remote Controller
13
Warning! Power cord and communication wire of Intelligent Remote
Controller must be arranged separately (with the distance over 15cm), otherwise it
may cause communication error of Intelligent Remote Controller!
The thin dotted line shown in the figure is communication wire, and heavy line
is heavy-current wire. The wires arranged in the figure are only for reference.
7.2 Communication Connection
Intelligent Remote Controller communication system includes:
(1)Communication between Intelligent Remote Controller and Intelligent
Remote Eudemon system;
(2)Communication between Intelligent Remote Controller with U-Match, rooftop
unit and the wired controller of water heater.
7.2.1 Selection of Material of Communication Wire
(1)Communication wire of Intelligent Remote Controller and Intelligent
Remote Eudemon system adopts standard Ethernet communication wire, length of
cable wire between controller and router (computer, interchanger, etc.) is not over
80 meters;
(2)Communication cable selection between Intelligent Remote Controller with
U-Match, rooftop unit and the wired controller of water heater.

Intelligent Remote Controller
14
Material
type
Communication
cable L(m)
between Intelligent
Remote Controller
with U-Match,
rooftop unit and the
wired controller of
water heater.
Wire
diameter
(mm2)
Material
standard Remark
Light/
general
PVC jacket
twisted pair
(RVVSP)
L≤500 ≥2
×
0.75
IEC
60227-5:
2007
Total
communication
distance
should not be
over 500m
7.2.2 Connecting Method of Communication Wire
(1)Communication connection between Intelligent Remote Controller and
Intelligent Remote Eudemon system;
(2)Communication connection between Intelligent Remote Controller and
wired controller of water heater (one Intelligent Remote Controller can connect to 16
wired controllers of water heaters at most).
Caution! All the communication wires under the Intelligent Remote Controller
must adopt series connection rather than star connection.

Intelligent Remote Controller
15
(3)Communication connection between Intelligent Remote Controller with
U-Match and rooftop unit (255 sets of U-Match or rooftop unit can be connected at
most).

Intelligent Remote Controller
16
7.2.3 Configuration of Communication Connection
(1)Connection of communication wire between Controller and PC:
Sketch map of connection between Intelligent Remote Controller and PC:
1) Adopt intersecting (or parallel) cable wire, Intelligent Remote Controller
connects to PC directly.
2) Adopt parallel (or intersecting) cable wire, Intelligent Remote Controller
connects to PC via router.
3) Connection of communication wire between Intelligent Remote Controller
and air conditioner:
When the controller connects to wired controller of water heater, the BMS
communication port (white port) of wired controller of water heater must be
connected in, only the middle two cores should be connected. When the controller
connects to wired controller of water heater, the controller must be in the head/end
of the connection position.
This manual suits for next models