DAN DRYER SOAPTAP 378 User manual

USER MANUAL
SOAPTAP Model 378
FOAMTAP Model: 382

Ø38
Ø50
220
15
Ø38
Ø50
311
88
117
D
Soap: D = ≤ 350 mm
Foam: D = ≤ 650 mm
TECHNICAL SPECIFICATIONS
DESCRIPTION DATA
Material Stainless steel - AISI 304
Voltage 6V DC, AC/DC adapter is included
Stand-by power 0.3-0.4W
Sensor type Infrared, self adjusting
Sensor range 20 mm - 150 mm. Standard 120 mm ± 20 mm, adjustable.
Soap/foam dosing volume 1-1.5 ml (soap), 0.6-0.8 ml (foam)
Soap pump service life 100,000 activations
Mechanism service life 500,000 activations
Soap container 1,500 ml
IP Class IP35
Net weight 1.9 kg
Gross weight 2.3 kg
PRODUCT TYPE / MODEL
378 Stainless steel, satin nish, SoapTap Wall
382 Stainless steel, satin nish, FoamTap Wall
IMPORTANT!
This product falls within the scope of the WEEE directive on recycling
and recovery of waste electrical and electronic equipment.
• This product should not be disposed of with general household waste.
• This product must be reused if possible.
• Contact your local authority for further details.
• This product may also be returned to the manufacturer/retailer for proper treatment,
recovery and recycling.
Dimensions and technical specications 3
General safety information 4
Installation 5
Installation height 8
User guide 8
Light indicator 8
Cleaning and maintenance 9
Rell of soap container 9
Calibration of sensor range 10
Troubleshooting and corrective actions 11
Symptoms and corrective actions: New soap dispenser 11
Symptoms and corrective actions: Used soap dispenser 11
Parts list 12
TABLE OF CONTENTS DIMENSIONS AND TECHNICAL SPECIFICATIONS
Dimensions
Unit of measurement: mm
2 3

!
D
Ceramic ≥250 mm
Brushed steel ≥300 mm
D
Sensor
WARNING
• Turn off the power to the unit before servicing or cleaning.
• Never modify the product.
• Never insert objects into any opening in the product.
• The product is not intended for playing purposes.
• Cleaning and user maintenance must be carried out by children.
• The product may only be used for the applications described in this manual.
• Do not use any accessories not recommended by the manufacturer.
• The product should be checked on a regular basis. Never use a defective or
malfunctioning unit
• Never make alterations to the product affecting its performance. DAN DRYER’s product
warranty does not cover product problems that result from misuse or alteration.
NOTE
If the power supply cord is damaged, it must be replaced immediately. Disconnect the electricity
supply cord according to instructions.
This product is not intended for use by persons (inclusive children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised
or have been given instruction concerning use of the product by a person responsible for their
safety.
Children should be supervised to ensure this product is used correctly.
GENERAL SAFETY INFORMATION INSTALLATION
• Make sure the main breaker is turned off. Installation must be carried out by a qualied
person in accordance with applicable standards in the country concerned.
2. Mark the desired position on the wall and drill a
Ø35 mm diameter hole.
3. Installation of the tap:
A) Push the screwed bushing through the hole
in the wall
B) Place gasket, disc, and nut on the threaded
coupling of the tap
C) Tighten with tool, be careful not to overtighten
the nut
Recommended wall
thickness: 10-30 mm
Gasket
Disc
Nut
Distance from
sensor to sink:
1. Check the required distance from sensor to sink.
30°
Sensor
Sensor eld of view:
Object distance 250 mm: D: ≤128 mm
Object distance 300 mm: D: ≤155 mm
Objects within range D may cause unintentional activation.
160 mm
2. Check the required distance from sensor to sink.
Recommended wall thickness: 10-30 mm
19 mm
≥170 mm
30°
A minimum distance
of 180 mm is required
between each tap
product.
≥180 mm
4 5

6 mm
INSTALLATION
5. Fasten bracket into the pre-drilled holes.
6. Connect the soft rubber tube to the outlet of the pump,
and place the pump into the soap container.
7. Connect the tube to the pump and the cables to
the control box.
4. Use a template to drill the holes for the bracket. Install
bracket close to Soap/Foam Tap; behind a wall, in a
cabinet, or under the sink.
8. Insert soap container 1.5 or 3 L. Conrm the container is
placed correctly to activate the dispenser. The fork should
be on top of the disc at the pump top.
INSTALLATION
9. Connect 6 V DC power supply to control box.
6 7

• Ensure easy access to maintenance
and cleaning of the unit.
• It is recommended to install a
power switch to the soap dispenser
to ensure easy disconnection of the
electricity supply before cleaning
and maintenance.
• Do not bend the hose too sharp. It
can increase the resistance in the
hose and reduce the ability of the
pump to deliver a full dose.
• Ensure unit is installed on solid and
stable background.
• Pay attention to the different
properties of the different liquids,
depending on the type of pump.
IMPORTANT!
USER GUIDE
• Place your hands approx. 10-14 cm under the sensor to activate the
dispenser. The dispenser will deliver 1-1.5 ml soap (0.6-0.8 ml foam)
• Remove hands after soap release
• Stops automatically when hands are moved away
INSTALLATION HEIGHT
LIGHT INDICATOR
Standby Solid green light
Active Pulsing light from green to red
Wrong type of soap/obstruction Flashing green and red light
Empty soap reservoir* Flashing green light
Sensor Nozzle
* Light indication for empty soap reservoir is based on a counter that resets when power
is switched off, e.g. when relling soap. The calculation is based on a 1.5 L soap reservoir
and will call for soap rell every 1.2 L (approx. 1000 activations). If using foaming soap
the empty reservoir indication ashes even though the reservoir is still half full. Remove
reservoir from wall bracket and place it back to reset the SoapTap unit.
CLEANING AND MAINTENANCE
Routine cleaning and maintenance is recommended.
CLEANING AND MAINTENANCE OF CONTROL BOX
• Cut the power
• Remove any dust and dirt
• Do not rinse with running water
• Use a damp cloth and mild cleaning solution. Never use cleaning detergents with
an abrasive effect
CLEANING AND MAINTENANCE OF TAP/SENSOR
• Do not rinse with running water
• Use a damp cloth and mild cleaning solution. Never use cleaning detergents with
an abrasive effect
• Clean sensor for dust and dirt to prevent unintentional activation
REFILL OF SOAP RESERVOIR
• Remove soap reservoir and pump unit from the control box
• Remove pump from soap reservoir and ll with soap
• Put the pump back in the lled reservoir. Install soap reservoir and pump in the control box
• NB! Do not remove the soft hose from the pump
D
Soap: D = ≤ 350mm
Foam: D = ≤ 650mm
8 9

TIMER SETTINGS
CALIBRATION OF SENSOR RANGE
• Cut the power
• Connect power to the dispenser
• Place your at hand close to the sensor until the green light on the front of the tap
turns off and starts ashing red.
• Move your hand to the desired activation distance
• The calibration setup has completed with the new distance when it starts blinking
green again.
TROUBLESHOOTING AND CORRECTIVE ACTIONS
SYMPTOM CORRECTIVE ACTION
The dispenser has stopped
dispensing • Ensure power is on.
• Ensure the soap reservoir is installed properly in it’s
holder.
• Ensure the hose is not bent or twisted.
• Ensure the tubing is installed correctly and ts tightly. A
broken hose will not t tightly on the pumpe, soap will
be dripping and it will eventually damage the control
box.
• Ensure exit nozzle, hose and pump are not clogged.
• Ensure that soap meets specied viscosity range:
SOAPTAP 378 viscosity 1cP - 3000cP.
FOAMTAP 382 viscosity 1cP.
Soap dispenser is malfunc-
tioning • Check the IR-sensor works properly (see section for
light indication p. 8).
• Clean sensor for dirt.
• Cut off power and reconnect to restart the system.
• You could try to calibrate the sensor range (see section
for sensor calibration).
• If the problem persists, replace the sensor.
The soap dispenser sounds
strained and it does not
dispense a full dose
• Ensure there are no bends, knots or kinks on the hose.
• Check if the nozzle, hose or pump is clogged.
• Ensure that soap meets specied viscosity range:
• SOAPTAP 378 viscosity: 1cP - 3000cP
FOAMTAP 382 viscosity: 1cP
Flashing green light • Conrm the unit’s reservoir is lled with soap.
• If soap reservoir is not empty, remove reservoir from
wall bracket and place it back to reset light indicator for
empty soap reservoir.
10 11

No. Description
1TAP wall-mounted
2End piece
3LED circuit board
4 Holder for LED circuit board
5Sensor and nozzle silicone liner
6 Sensor and holder for nozzle (lower part)
8Holder for nozzle (upper part)
9 Bushing Ø34 mm with thread
10 Rubber gasket for bushing
11 Disc
12 Gasket big
13 Nut
14 Tube/nozzle connecting link
15 Nozzle for FOAM
16 Nozzle for SOAP
18 Soap tube for SOAP/FOAM
19 Control box
20 Mounting plated for control box and soap
container
21 Tools for fastening of nut
22 Soap container 1.5 L / 3 L
23 Pump FOAM
24 Pump SOAP
25 AC-adapter
PARTS LIST
12 13

14 15

DAN DRYER A/S
Alsikevej 8
DK - 8920 Randers NV
Tel: +45 8641 5711
Email: info@dandryer.dk
dandryer.com
This manual suits for next models
1
Table of contents
Other DAN DRYER Household Appliance manuals
Popular Household Appliance manuals by other brands

Milkcan
Milkcan MCL13024 instructions

Microban
Microban Wall-Mount Showerhead PO6100MB user manual

Ergolux
Ergolux ELX-SD01-C16 instruction manual

Harbor Freight Tools
Harbor Freight Tools 90416 Assembly and operation instructions

Bresser
Bresser Giessmelder 70-20100 instruction manual

Marta
Marta MT-2233 user manual