manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Danfoss
  6. •
  7. Thermostat
  8. •
  9. Danfoss living connect Z User manual

Danfoss living connect Z User manual

This manual suits for next models

1

Other Danfoss Thermostat manuals

Danfoss TP75 Operating manual

Danfoss

Danfoss TP75 Operating manual

Danfoss RTW-RA User manual

Danfoss

Danfoss RTW-RA User manual

Danfoss ECtemp 550 User manual

Danfoss

Danfoss ECtemp 550 User manual

Danfoss DEVIreg Smart User manual

Danfoss

Danfoss DEVIreg Smart User manual

Danfoss 088U0212 User manual

Danfoss

Danfoss 088U0212 User manual

Danfoss TP75M User manual

Danfoss

Danfoss TP75M User manual

Danfoss RT51 User manual

Danfoss

Danfoss RT51 User manual

Danfoss TP5001 series User manual

Danfoss

Danfoss TP5001 series User manual

Danfoss ECtemp 330 User manual

Danfoss

Danfoss ECtemp 330 User manual

Danfoss Eco User manual

Danfoss

Danfoss Eco User manual

Danfoss HC75-1 Operating manual

Danfoss

Danfoss HC75-1 Operating manual

Danfoss Eco User manual

Danfoss

Danfoss Eco User manual

Danfoss LinkFT User manual

Danfoss

Danfoss LinkFT User manual

Danfoss BasicPlus2 WT-T User manual

Danfoss

Danfoss BasicPlus2 WT-T User manual

Danfoss ECL Comfort 310 User manual

Danfoss

Danfoss ECL Comfort 310 User manual

Danfoss DEVIreg Touch User manual

Danfoss

Danfoss DEVIreg Touch User manual

Danfoss TS715 Si Assembly Instructions

Danfoss

Danfoss TS715 Si Assembly Instructions

Danfoss ECL Comfort 210 User manual

Danfoss

Danfoss ECL Comfort 210 User manual

Danfoss TPOne-M User manual

Danfoss

Danfoss TPOne-M User manual

Danfoss DEVIreg 610 User manual

Danfoss

Danfoss DEVIreg 610 User manual

Danfoss SET 3E User manual

Danfoss

Danfoss SET 3E User manual

Danfoss Icon Master User manual

Danfoss

Danfoss Icon Master User manual

Danfoss REP24 User manual

Danfoss

Danfoss REP24 User manual

Danfoss ECtemp Smart User manual

Danfoss

Danfoss ECtemp Smart User manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
VQIDC202 © Danfoss 12/2014
Quick Guide
living connect® Z,
Electronic Radiator Thermostat
Preparation
living connect® Z is an electronic radiator thermostat, intended
for use with water based room radiators. It can be controlled by
a Z-Wave certied controller, which supports the appropriate
command classes.
Z-Wave
controller
living connect® Z
sensor
living connect® Z is supplied with adapters for Danfoss RA valves
and valves with M30 x 1.5 (K) connections, two alkaline AA bat-
teries and a 2 mm Allen key.
Inserting the batteries
Remove the battery cover and insert two AA
batteries. Make sure the batteries are correctly
oriented.
Rechargeable batteries must not be used.
When replacing batteries the programme set-
tings will be preserved, but after two minutes
the settings for time and date are reset.
Installing living connect® Z
Mmust be ashing on the display prior to installing.
1. Start by mounting the ap-
propriate adapter.
RA
K
2. Tighten RA adapter using the
Allen key, hand-tighten the K
adapter (max. 5 Nm).
3. Screw the thermostat onto
the adapter and tighten by
hand (max. 5 Nm).
4. A large Mashes, press to x the thermostat.
Including the device to a network
Z-wave
controller
• Ensure living connect® Z is factory reset.
• Activate “Inclusion” on the Z-Wave controller.
• Quickly press and release on living connect® Z.
• Observe both controller and living connect® Z for status of the
process.
Testing the connection
Press for at least 3 seconds until Mis displayed.
Press until LI is displayed.
Press to test the connection.
LI disappears when the connection is made.
If no connection can be made, the alarm symbol
and the antenna symbol ashes.
Display and buttons
Battery symbol
The set temperature
Network connection
Lock
Alarm
Use to navigate the display and the menus and to set the
temperature, and use to select and conrm.
Quick Guide living connect® Z, Electronic Radiator Thermostat
2VQIDC202 © Danfoss 12/2014
Temperature control and adjustment
The temperature is usually con-trolled via
the controller, but may be changed at any
time using the thermostat’s buttons.
If this is done, the thermostat sends a
message to the controller, which then
syncronises other thermostats in the
same room.
18
19
20
21 26
25
24
23
Press to change
the temperature.
Excluding the device from the network
• Activate“Exclusion” on the Z-Wave controller.
• Quickly press and release on living connect® Z.
• Observe both controller and living connect® Z for status of the
process.
Re-installation mode
If the thermostat has been removed from
the radiator and needs to be reinstalled
(after being used), it is necessary to activate
installation mode to prevent damage to the
thermostat.
To enter installation mode:
• Press until Mis displayed.
• Press to withdraw the spindle. Mashes.
• Reinstall the thermostat on the valve.
• Press for approx. 3 seconds to x the thermostat.
If the thermostat is moved to another room, make sure to make
the necessary changes in the controller.
Factory reset
Remove the battery cover and take out one battery. Press and
hold for approx. 5 seconds, while re-inserting the battery.
living connect® Z is now factory reset and in mounting mode.
Wake up
A controller can only communicate with living connect® Z, when
the device is awake. The intervals when the thermostat is awake
can be set using the “wake up command class”.
Press to manually wake up the device. It will stay awake for 10
seconds and send out a node info.
Z-wave info
Device type Slave
SDK 4.55
Software version 1.01
ProduktID 4
Explorer frames YES
Implemented Z-Wave device classes
Z-Wave
Device Classes
Device Class
Implemented
Generic device GENERIC_TYPE_THERMOSTAT
Specic device SPECIFIC_TYPE_SETPOINT_THERMOSTAT
Supported and controlled Z-Wave command classes
Z-Wave Command
Classes Supported Description
COMMAND_CLASS_BATTERY Get current battery status of
living connect®.
COMMAND_CLASS_CLIMATE_
CONTROL_SCHEDULE
Control a temperature oset
to the thermostat setpoint of
living connect®. The tem-
perature oset is dened
by schedules and schedule
overrides.
COMMAND_CLASS_CLOCK Set or get the current living
connect® clock.
COMMAND_CLASS_
MANUFACTURER_SPECIFIC
Get manufacturer ID of
system.
COMMAND_CLASS_MULTI_
CMD
A special Z-Wave command
used by living connect® to en-
capsulate multiple commands
in one command and thereby
conserve battery life.
COMMAND_CLASS_
PROTECTION
Set or get living connect® local
protection mode. Possible lo-
cal protection values are:
0 = no protection
2 = fully locked (tamperproof)
COMMAND_CLASS_
THERMOSTAT_SETPOINT
Set or get current thermostat
setpoint of living connect®.
Heating setpoint is the only
supported setpoint type.
COMMAND_CLASS_VERSION Get version of product and
command classes.
COMMAND_CLASS_WAKE_UP
A special Z-Wave command
used by living connect® to
synchronize communication
with its controller.
Quick Guide living connect® Z, Electronic Radiator Thermostat
3
VQIDC202 © Danfoss 12/2014
Technical requirements and info
• After a succesful inclusion the controller must send a WAKE_
UP_INTERVAL_SET command to living connect® Z in order to
specify where and when living connect® Z should communicate
wirelessly. If not, the thermostat cannot perform wake ups and
the alarm and antenna symbols will ash.
• The nodeID set in the WAKE_UP_INTERVAL_SET command
must be for a permanently listening device which reponds to
the commands sent from living connect® Z. This means PC’s with
USB sticks will only work if the PC is never turned o.
• If living connect® Z does not get correct and timely replies (e.g.
if the controller is turned of) it will automatically switch to 30 min-
utes wake up intervals. If at next wake up the controller replies
as expected, living connect® Z will switch back to the original
wake up interval.
• After sending the WAKE_UP_INTERVAL_SET command, the
controller must assign return routes, so living connect® Z can
reach its destination, i.e. the no-deID set in the WAKE_UP_IN-
TERVAL_SET command.
• living connect® Z will not commence its periodic communications
if it is in “Mounting mode”. “Mounting mode” is for physical
installation and should not be confused with “Inclusion”. Please
see section “Installing living connect® Z, item 4” for instructions
on how to leave “Mounting mode”.
• Although living connect® Z supports single commands, multi
commands must always be used to ensure two years battery
lifetime.
• If multiple thermostats are installed in the same room, it is
important that the controller ensures they all have the same
schedule and the same setpoint.
Troubleshooting
Error code Action
E1, E2, E3, E4 Contact your local Service Technician.
E5
The thermostat is not receiving the expected
replies from the control system.
Check that you have a Z-wave certied
controller running and it has the necessary
functionality to control the thermostat (see
“Technical requirements”).
Technical specications
Thermostat type Programmable electronic radia-
tor valve controller
Recommended use Residential (pollution degree 2)
Actuator Electro-mechanical
Display Grey with back-light
Software classication A
Control PID
Transmission frequency 868.42 MHz
Transmission range up to 30 m
Power supply 2 x 1.5V AA alkaline, class III
Power consumption 3 µW in standby,
1.2 W when active
Battery life 2 years
Low battery signal
Battery icon will ash in display.
If battery level is critical, the
display will ash.
Ambient temperature 0 to 40°C
Transportation temperature -20 to 65°C
Max. water temperature 90°C
Temperature setting range 4 to 28°C
Measurement interval Measures temperature every
minute
Clock accuracy +/- 10 min./year
Spindle movement Linear, up to 4.5 mm, max. 2 mm
on valve (1 mm/s)
Noise level <30 dBA
Safety classication Type 1
Weight 177 g incl. RA adapter
IP class* 20
Tested for safety and EMC requirements as specied in EN 60730-1,
EN 60730-2-9 and EN 60730-2-14.
Safety precautions
The thermostat is not intended for children and must not be
used as a toy.
Do not leave packaging materials where children may be
tempted to play with them, as this is extremely dangerous.
Do not attempt to dismantle the thermostat as it contains no
user-serviceable parts. If error code E1, E2 etc. is shown in the
display or other defects appear, please return the thermostat
to the distributor.
Quick Guide living connect® Z, Electronic Radiator Thermostat
4VQIDC202 © Danfoss 12/2014