manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dantherm
  6. •
  7. Water Filtration System
  8. •
  9. Dantherm 028084 User manual

Dantherm 028084 User manual

This manual suits for next models

1

Other Dantherm Water Filtration System manuals

Dantherm ELITE 400 User manual

Dantherm

Dantherm ELITE 400 User manual

Dantherm HRV 5 User manual

Dantherm

Dantherm HRV 5 User manual

Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

Atlantic Ultraviolet

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun CBG-500 Operation manual

SunSun

SunSun CBG-500 Operation manual

Hayward XStream Filtration Series owner's manual

Hayward

Hayward XStream Filtration Series owner's manual

Contech DownSpout StormFilter Operation and maintenance

Contech

Contech DownSpout StormFilter Operation and maintenance

Teka Airfilter MINI operating instructions

Teka

Teka Airfilter MINI operating instructions

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
028391 •Version 1.2 • 29-08-2013
Exchange DC inrush filter
RBS5000
Part instruction
Rev. 1.2
en
2
Der tages forbehold for trykfejl og ændringer
Dantherm can accept no responsibility for possible errors and changes
Irrtümer und Änderungen vorbehalten
Dantherm n’assume aucune responsabilité pour erreurs et modifications éventuelles
3
028391 •Version 1.2 • 29-08-2013
How to replace the inrush DC filter in RBS5000
When to replace
Dantherm Air Handling recommend replacing the inrush DC filter only when broken.
Part number
A new inrush DC filter can be ordered under part number:
028084 Ericsson no. NTM 201 3383. (upgrade kit), or
028079 Ericsson no. 5/BPD 104 36/2 (spare part)
Tools
Make sure you have the following tools available before your start the replacement:
Torx 10/20/25 screwdriver
Caution!
Only trained and certified technicians are allowed to replace parts
Switch off all the power to the unit before working on it
-Make sure all work has been performed before switching on the power again
Contents of the
box
Please check the contents of the box before you start the replacement:
1 inrush DC filter
1 insulation plate
Insulation for inrush filter
Instruction
Illustration
This drawing illustrates the RBS 5000 unit:
Continued overleaf
4
How to replace the inrush DC filter in RBS5000, continued
Procedure, remove
the filter
Follow this procedure to remove the old inrush DC filter:
Step
Action
1
Disconnect the AC/DC plugs and the communication plug on front of the unit
2
Dismount the front panel
by unscrewing the 9 torx
25 screws
3
Remove the internal fan
carefully by unscrewing
the 1 torx 25 screw
4
Remove the AC appliance
inlet from the mounting
hole by unscrewing the
two screws in front. (torx
10)
Note the two nuts on the
back side.
Leave the mounting hole
in the unit
Continued overleaf
5
028391 •Version 1.2 • 29-08-2013
How to replace the inrush DC filter in RBS5000, continued
Procedure, remove
the filter, continued
Step
Action
5
Remove the voltage selec-
tor by following these
steps:
Pull up the mounting
guard
Pull back the voltage
selector and leave it in
the unit
Unscrew the nut on
the backside of the
voltage selector front
panel and remove it.
6
Remove the wires to the
inrush DC filter
2 red/2 blue wires in 2
plugs
7
Dismount the inrush DC filter by unscrewing the 4 torx 20 screws
8
Replace the old inrush DC filter by following the procedure in the following block
Procedure, replace
the filter
Follow this procedure to put in a new DC filter:
Step
Action
1
Remove the old (if any) insulation plate
2
Mount the insulation plate behind the inrush DC filter
3
Mount the filter with the 4 Torx 20 screws
4
Mount the cables to the filter + to red and –to blue
5
Mount the voltage selector front cover with the mounting nut
6
Press the voltage selector body back on voltage selector
7
Mount the appliance inlet with the 2 torx 10 screws and nuts
8
Mount the internal fan with 1 torx 25 screw
9
Mount the unit front cover 9 torx 25 screws
10
Power up the unit and test it with the test button on the control board
1)
2)
3)
6
7
028391 •Version 1.2 • 29-08-2013
Contact Dantherm
Dantherm Air Handling A/S
Marienlystvej 65
7800 Skive
Denmark
Phone +45 96 14 37 00
Fax +45 96 14 38 00
[email protected]
www.dantherm.com
Dantherm AS
Postboks 4
3101 Tønsberg
Norway
Besøksadresse: Løkkeåsvn. 26
3138 Skallestad
Phone +47 33 35 16 00
Fax +47 33 38 51 91
[email protected]
www.dantherm.no
Dantherm Air Handling AB
Virkesgatan 5
614 31 Söderköping
Sweden
Phone +(0) 121 130 40
Fax +(0) 121 133 70
[email protected]
www.dantherm.se
Dantherm Air Handling (Suzhou) Ltd.
Bldg#9, No.855 Zhu Jiang Rd.,
Suzhou New District, Jiangsu
215219 Suzhou
China
Phone +86 512 6667 8500
Fax +86 512 6667 8500
[email protected]
www.dantherm-air-handling.com.cn
Dantherm Limited
12 Windmill Business Park
Windmill Road, Clevedon
North Somerset, BS21 6SR
England
Phone +44 (0)1275 87 68 51
Fax +44 (0)1275 34 30 86
[email protected]
www.dantherm.co.uk
Dantherm Air Handling Inc.
110 Corporate Drive, Suite K
Spartanburg, SC 29303
USA
Phone +1 (864) 595 9800
Fax +1 (864) 595 9810
[email protected]
www.dantherm.com
8
Dantherm Air Handling A/S
Marienlystvej 65
7800 Skive
Denmark
www.dantherm.com
service@dantherm.com
*028391*