David Engineering & Mfg PDR PSTM4060 User manual

Model PSTM4060
Features
1
Mounts by
A division of David Engineering & Mfg. Inc.
Thank you for purchasing this PDR mount product
To ensure the correct usage, please read and follow the instructions manual thoroughly. Please store the instructions in a safe
place for future reference.
All PDR mounts and adapters carry a limited lifetime warranty against defects in material and workmanship.
Check the PDR website for details @ www.PDRmounts.com. We are not liable for improper installation that results in damage
to mounts, adapters or presentation equipment.
Special techniques may be necessary for installation of the panel display mount.
?Do not attempt to perform this work by yourself. Always have a helper
?If you are not capable of the installation, request an installation specialist to install this unit.
?Manufacturer assumes absolutely no responsibility for injuries and damages that may occur due to improper installation and handling.
?Please remember that if you remove the panel display from the wall later, you will find the screw holes and anchor bolts for the mounting
unit left on the wall. Also note that long use of the panel display may discolor the wall around it due to its heat and airflow.
To ensure customer safety, be sure to decide the installation location so that the strength is sufficient to withstand the weight of both the display and the mount.
Always use at least two persons for all installations. Fully tighten all of the mounting screws as specified in the installation instructions.
?Simple 3 piece design
?Low profile 5/16” ( 8 mm)
?Fits displays with mounting holes not exceeding 857mm left to right and 435mm top to bottom
?Recommended for 40” to 60”
?Auto-loc mounting feature (patent pending)
?150lb load rated
?Wall mount to 16” or 24” wood stud location
?Lifetime warranty
?Made in the USA

INSTALLATION LOCATION
INSTALLATION ON A WOODEN WALL
CAUTION
WARNING
WARNING
Rev 11/01/09
The wall where the wall mount is to be installed must be capable of long-term support of the total load of
the panel display and wall mount. Measures should also be taken to ensure sufficient strength to
withstand the force of earthquakes, vibration and other external forces.
Note: Incorrect installation can cause the panel display to fall and cause injury.
Total load of the panel (panel display + wall mount)
MAXIMUM WEIGHT - 150 Lbs. ( 68 Kg.)
Always install so that the load is supported by a wood stud. If the strength of the wood studs is not sufficient, add reinforcement.
Do not install on decorative posts or plaster board. Always confirm the center of the stud is used for the installation.
Avoid installing in locations where the temperature and humidity are excessively high, and where contact with any water is possible.
These can result in fire or electric shock.
Do not install close to an air conditioner intake or outlet.
Do not install in locations where there are excessive amounts of dust, oily smoke or tobacco smoke. Fire could result.
Do not block the ventilation holes. Leave sufficient clearance in regard to the surroundings to avoid blocking the ventilation.
The internal temperature could elevate and possibly result in fire. Install the panel (4") or more away from surroundings.
Install only on a vertical surface. Avoid sloped surfaces. Also, do not install facing upward. The internal temperature could
elevate and possibly result in fire. Injury or damage could also result from falling.
Do not install in locations where there is excessive vibration or impact. Injury and damage could result from the panel display
falling.
Do not install where there is direct sunlight or other strong light. Strong light could result in eye fatigue during usage.
Use the specified bolts and screws in the specified places and tighten firmly. Failure to do this could cause injury if the panel
display falls.
Do not alter any of the parts. Do not use broken parts. This could result with injury due to the panel display falling.
Make sure that both hooks from the each bracket engage with the wall bracket . Failure to do so could cause the panel
display to fall.
Always use at least two people to perform the installation work. Injury could result from dropping heavy objects.
2

DRAWING SPECIFICATIONS
3
17.13
MAX
435
35.235
2.43
Ø .320TYPICAL
.280
X 2.88 SLOT TYPICAL
33.74
MAX
857 .315
20.31

Wall mount bracket…1 pc
A
B
C
I
H
J
K
Plastic spacer...4 pcs
Display bracket .... 2 pcs
E
D
F
Square multi-mount washers...4 pcs
use with D,E,F,H,I,J mounting screws
G
PARTS LIST
4
m14 x 2.5 phillips screw ...3 pcs
m8 x 40mm phillips screw... 4req
m6 x 40mm phillips screw... 4 req
m5 x 40mm phillips screw...4 req
m8 x16mm phillips screw...4 pcs
m6 x 16mm phillips screw...4 pcs
m5 x16mm phillips screw...4 pcs

MOUNTING THE ARMS TO THE DISPLAY
NOTE: Do not over tighten the bracket mounting screws as damage to the display internal mounting threads could occur.
Fig 1
Fig 2
Mounting hardware D,E,F,H,I,J
Square Multi-mount washer ( G )
Panel display TOP edge
Display bracket ( A )
Optional plastic spacers ( K )
1: Place the display panel face down on a protected surface.
2: Position the bracket (A) with the hooks facing towards the top See Fig 1 & Fig 2
3: Attach the bracket using the mounting holes that will place the top of the bracket closest to the top of the display,
using the proper screws and the square multi-mount washers supplied (D,E,F,H,I,and J)
4:NOTE : In some applications the plastic spacer (K ) and longer screws ( D.E.F )may be required to add clearance for the
back panel to allow enough tilt to locate on the wall mount bracket ( B )
Do not over tighten hardware, damage to the display may result.
place bracket (A) closest
to the top of the display
Viewing Centerline
(centerline of display)
Measure this offset distance
VIEWING HEIGHT AND OFFSET
5

WOOD STUDS
MOUNTING DISPLAY ON THE WALL BRACKET
XXXX
Fig 3
Fig 4
FLOOR LINE
VIEWING
HORIZONTAL
CENTER LINE
1: The bracket must be secured to the centered on 2 or 3 wall studs capable of holding at least four times the weight of the unit.
2: Use a stud finder to determine the stud center line of the wall stud.
3: Use the sketch from FIG 2 to determine the height of the wall mount bracket (B).
4: Pre drill 1/8” (3mm) holes for the lag bolts Fig 3.
5: With the flange facing up on the wall bracket, use the 3 lag bolts ©
level and secure the mounting plate to the center of the wall studs. See Fig 3
FASTEN MOUNTING PLATE TO WALL
Add offset from FIG 2
1: Place the display with bracket (A) attached onto the wall bracket (B) SEE FIG 4
2: The Display bottom needs to be puled away from the wall about 20 degrees, and lowered onto the wall bracket
and allowed to rest on the wall.
3: The mount cannot be removed or accidently dislodged from the wall unless the bottom is pulled away 20
degrees and lifted up.
6
STANDARD 2 X 4 CONSTRUCTION
16” OR 24” SPACING
Caution DO NOT OVER TIGHTEN LAG BOLTS

this page is blank
Table of contents
Popular TV Mount manuals by other brands

VONROC
VONROC TM501XX Original instructions

Digital Watchdog
Digital Watchdog NightWatch DW-ILWM1 quick start guide

PEERLESS
PEERLESS HLG452-002 Installation and assembly manual

QualGear
QualGear QG-TM-020-BLK installation manual

Zebco
Zebco RHINO BLX 65 BMR manual

AUDAC
AUDAC MBK1 V Series installation manual