DecoRad Handmate UV 1800 User manual

Handmate UV 1800 Firmware 2.9
2
Preface
The DecoRad® Handmate UV 1800 is the ultimate tool for instantly curing UV (floor)
coatings.
UV has been used successfully for many years already for instantly curing inks, car
paints, glues and coatings. The DecoRad® Handmate UV 1800 is the result of the many
years' experience of DecoRad® Systems with on-site use of UV in combination with
coatings, varnishes and oils.
DecoRad® Systems has succeeded in providing the latest equipment and best
technology.
Characteristics of the DecoRad® Handmate UV 1800
•Output 1800 Watt
•CE marking
•ISO 9001
•Compact and user-friendly
•1 Ultraviolet lamp 18 cm
This user manual provides the user with information about the safe usage and maintenance
of the DecoRad® Handmate UV 1800.
Carefully read through this user manual before using the
the Handmate.
The DecoRad® Handmate UV 1800 can only be operated by sufficiently
qualified personnel.
Keep this user manual with the DecoRad® Handmate UV 1800.

Handmate UV 1800 Firmware 2.9
3
Contents
DecoRad® Handmate UV-1800
1
Preface
2
Contents
3
1.1
Manufacturer
4
1.2
CE-Marking
4
1.3
Guarantee
5
1.4
Copyright
5
1.5
Liability
5
2
Safety
6
2.1
Safety symbols in this user manual
6
2.2
Symbols on the DecoRad® Handmate UV-1800
6
2.3
Usage
7
2.4
Maintenance
7
2.5
Safety regulations
7
2.6
UV-radiation
7
2.7
Risks of UV-radiation
8
2.8
User
9
3
Machine description
10
3.1
Function
10
3.2
Overview of the DecoRad® Handmate UV-1800
10
3.3
Control elements
11
3.4
Standard equipment
11
4
Putting into operation
12
4.1
How to start
13
4.2
How to stop
14
5
Error messages
15
6
Replacing lamp
16
7
Specifications
17
CE Declaration
18

Handmate UV 1800 Firmware 2.9
4
Carefully read through this user manual before using the
DecoRad® Handmate UV 1800.
The DecoRad® Handmate UV 1800 can only be operated by sufficiently
qualified personnel.
1.1 Manufacturer
The DecoRad® Handmate UV 1800 is manufactured by:
DecoRad® Systems bv
Fokkerstraat 25
3905 KV Veenendaal
The Netherlands
Phone: +31(0)318-550425
E-mail: [email protected]
www.decorad.com
For any questions regarding sales orders, deliveries, parts or shipments, please contact
DecoRad® Systems bv.
1.2 CE-marking
The DecoRad® Handmate UV 1800 comes with a CE marking. This means that the
Handmate meets the fundamental safety demands of the European Community.

Handmate UV 1800 Firmware 2.9
5
1.3 Guarantee
The manufacturer of the DecoRad® Handmate UV 1800 provides a 12 month warranty
(carry-in) for parts and repair costs*. This warranty is only valid if the DecoRad® Handmate
UV 1800 is used according to the specifications and the user and maintenance instructions
are observed.
The DecoRad® Handmate UV 1800 warranty lapses in case of:
-Inexpert use
-Insufficient or inexpert maintenance
-Alterations without prior written permission of the manufacturer
The normal replacement parts (bulbs) do not fall under the factory warranty.
* At the discretion of DecoRad® Systems bv
1.4 Copyright
Copyright © DecoRad® Systems bv.
All rights reserved. Nothing from this publication can be multiplied, stored in an automated
file and/or made public in any form, either electronically, mechanically, by photocopies,
recordings, or any other way without prior written consent of the manufacturer.
1.5 Liability
The manufacturer of the DecoRad® Handmate UV 1800 is not liable for unsafe situations,
accidents or damage as a consequence of:
-Ignoring warnings or instructions as stated on the DecoRad® Handmate UV 1800 or
as described in this user manual (including not correctly applying personal protection
measures).
-The use of the DecoRad® Handmate UV 1800 for any other application or in any
other circumstances than indicated in this user manual.
-Making any kind of alterations to the DecoRad® Handmate UV 1800. This also
pertains to applying other replacement parts.
-Intensity of the usage is decisive for the degree of maintenance.
The manufacturer is not liable for consequential loss in case of malfunctions of the
DecoRad® Handmate UV 1800, such as damage to products, business interruption,
production loss, etc.

Handmate UV 1800 Firmware 2.9
6
2. Safety
This chapter describes the safety measures pertaining to the DecoRad® Handmate UV
1800. Carefully read this chapter before putting the DecoRad® Handmate UV 1800 into
operation or performing maintenance work.
2.1 Safety symbols in this user manual
The following symbols are used in this user manual:
A comment draws the user's attention to possible problems.
Danger of damage to the DecoRad® Handmate UV 1800 if the instructions
are not carefully executed.
2.2 Symbols on the DecoRad® Handmate UV 1800
The following symbols can be found on the DecoRad® Handmate UV 1800:
Always wear the UV protective DecoRad® face shield
Always wear the UV protective DecoRad® suit
Always wear the UV protective DecoRad® gloves
Caution ! Hot Surface !
Caution ! UV light ! Never look directly into the UV light without wearing eye-
and face protection.
Keep the room well ventilated. Depending on the type of lamp, the UV-lamp
can produce ozone.
The user/maintenance mechanic should be acquainted with the entire contents
of this user manual, before using the DecoRad® Handmate UV1800

Handmate UV 1800 Firmware 2.9
7
2.3 Usage
The DecoRad® Handmate UV 1800 can only be operated by qualified personnel.
The safety instructions described in this manual should be observed. If
you deviate from these instructions, this can lead to serious personal or
material damage.
2.4 Maintenance
The DecoRad® Handmate UV 1800 can only be operated by qualified personnel.
The safety instructions described in this manual should be observed. If
you deviate from these instructions, this can lead to serious personal or
material damage.
The maintenance mechanic should be acquainted with the entire contents of this user
manual.
Intensity of the usage is decisive for the degree of maintenance.
Examples of this are:
- Cleaning of the housing
- Cleaning the UV lamps (dirt causes a decrease in UV yield and the number of burning-
hours >500)
- Cleaning the reflector (dirt causes a decrease in UV yield and the number of burning-
hours >500)
2.5 Safety regulations
The DecoRad® Handmate UV 1800 meets the fundamental safety and health demands of
the relevant guidelines of the European Community.
Stay alert for dangerous situations!
2.6 UV radiation
Ultraviolet radiation (or UV) is a proven process to disinfect water, air and solid surfaces
which have been contaminated with micro-organisms. In addition to this, UV radiation is
well-known for its application as a catalyst in drying processes. The effects of UV as a
disinfectant have been extensively documented in scientific research.
UV radiation is a mixture of radiation of various wavelengths. In a rainbow, the visible part of
the UV radiation is ordered according to the length of the waves. Progressing from purple to
red, the waves become increasingly longer. The ultraviolet or UV has a wavelength shorter
than that of purple. This part of the UV radiation is not visible as well.

Handmate UV 1800 Firmware 2.9
8
Most of the UV radiation we get comes through sunlight. Not all UV radiation reaches the
earth: a part is blocked by the ozone layer.
2.7 Risks of UV radiation
Both UVA and UVB can damage cells and genetic material, thus leading to skin cancer.
UVB poses the greater risk here. Even though scientists used to think that UVA was not
harmful, newer research has proven that UVA contributes 10 to 20 percent to the cancer
risk.
In order to protect itself against damage to genetic material, the skin tries to thicken itself
(after UVB exposure). Pigment cells create the substance melanin, which gives the skin a
brown colour. This means that when the skin tans, it has already been damaged.
Because the ozone layer is becoming increasingly thinner due to environmental
pollution, less UV radiation is absorbed, thus leading to an increase of skin cancer
occurrences.
In addition, the skin can burn under influence of UVA and UVB radiation. Burning is
accompanied by redness and in serious cases tremors, blisters, nausea and fever. In
the long term the skin will lose its elasticity, suffer from accelerated aging and will
remain sensitive for itching, pimples, etc.
Ultraviolet light can damage skin and eyes.
Wear the UV facial shield, protective clothes and gloves.
As a user, never look directly into a switched-on lamp.
Certain types of medication and cosmetics can increase sensitivity.

Handmate UV 1800 Firmware 2.9
9
2.8 User
Carefully read through this user manual before operating the DecoRad®
Handmate UV 1800.
Before switching on the DecoRad® Handmate UV 1800, ensure that
the personal protection tools as described in the user manual are used.
The UV facial shield and skin covering clothes (including gloves) are
obligatory.
Dirt on the lamp and/or reflectors (e.g. from coatings or fingers)
can shorten the life span of the lamp or reduce the UV
effect. If needed, clean the cooled down lamp with isopropyl
alcohol and paper towel.
Please make sure that bystanders without appropriate UV protection are
at a safe distance of at least 6 meters / 20 ft
In order to prevent damage to the DecoRad® Handmate UV 1800 and the
user, the user is strictly prohibited to work with tools on the DecoRad®
Handmate UV 1800 in any other way than indicated in this user manual
for the purpose of maintenance.
VENTILATION
In case of using a UV C lamp keep the room ventilated.
The UV C lamp is full spectrum, so there is ozone production.

Handmate UV 1800 Firmware 2.9
10
3. Machine description
This chapter describes the parts and operational use of the DecoRad® Handmate UV 1800.
3.1 Function
The DecoRad® Handmate UV 1800 is the ultimate tool for instantly curing UV (floor)
coatings. Please consult our website, www.decorad.com for a recent overview of
suitable products!
3.2 Overview of the DecoRad® Handmate UV 1800
1. Box
2. Control / power unit
3. UV lamp-unit
4. Start / stop station
5. UV facial shield / gloves / Tyvek suit
6. Extension pole (optional)
7. Support wheel (optional)
6
p
7
6
p

Handmate UV 1800 Firmware 2.9
11
3.3 Control elements
The following buttons can be found on the control panel:
1. On / off switch = power
2. On / off switch = UV lamp
3. Operation button = Dim or Full Power (on the lamp-unit)
* UV full power can be ignited with the button on the Handmate and / or on the
extension pole (optional)
3.4 Standard equipment
1. Box
2. Control / power unit
3. UV lamp-unit
4. Start / stop station
5. UV facial shield / gloves / Tyvek suit
Optional:
- extension pole
- support wheel
- spare bulb
3

Handmate UV 1800 Firmware 2.9
12
4. Putting into operation
Always wear skin protective clothes (UV
facial shield, gloves and clothes)!
Warning: The bottom of the lamp unit can
become hot!
The HandMate UV has a power cable of
225 centimeters.
Connect the power cable to a suitable
power source.
Mains: 110 –250 Vac / 50 –60 Hz /
10/20A
Adjust the (optional) extension pole. (or
the small handle; not necessary to
connect the data cable, use the button on
the lamp unit –small handle has no data
cable!)
Connect the extension pole to the lamp
unit.
Connect the data cable of the extension
handle to the back of the lamp unit
This is a male/female connection

Handmate UV 1800 Firmware 2.9
13
4.1 HOW TO START
Press the ON button.
The green indicator will burn. On the
display of the lamp unit the text DONE will
be shown.
Press the button with the “lamp symbol”.
The green indicator will burn.
On the display of the lamp unit the text
WAIT will be shown
When DIM is shown in the display, the
HandMate UV 1800 is ready to use
Use the button on the lamp unit or the
extension handle to start UV curing
(FULL)
ATTENTION
UV curing in FULL power only with a
distance to the object of 2 –3 cm.
ATTENTION: When DIST is shown in the
display and a beeping signal can be
heard, distance to the object is too large.
UV curing is no longer possible.
Move the lamp unit in a position approx. 3
centimeters from the surface. The beeping
signal will stop. The text DIM will be
shown on the display. From here you can
start curing in FULL.
After 1 minute DIST the text U51 appears
on the display. Turn off the lamp button.
Display moves to COOL and after 8
minutes to DONE.
After leaving the Handmate 5 minutes in
DIM on the start/stop station, U94 appears
on the display. Turn off the lamp button.
Display moves to COOL and after 8
minutes to DONE.

Handmate UV 1800 Firmware 2.9
14
4.2 HOW TO STOP
From DIM switch off the UV lamp when
ready. The text COOL will be shown.
Leave the HandMate UV 1800 attached to
the power source until DONE is shown.
Press the off button
Please unplug the HandMate UV 1800
entirely from any power source.

Handmate UV 1800 Firmware 2.9
15
5. Error messages
EXPLANATION OF THE DISPLAY MESSAGES
Error
Description
Solution
E13
Lamp start fail
Turn both switches OFF.
Start from 4 PUTTING INTO OPERATION.
In case of recurrence E13, please consult DecoRad®
Systems
E14
(TEMP)
Over-
temperature
The UV lamp is too hot, leave the UV lamp to cool down
for 5 minutes. Turn both switches OFF.
Start from 4 PUTTING INTO OPERATION.
In case of recurrence, please consult DecoRad® Systems
E15
(FAN)
Fan fail
Leave the UV lamp to cool down for 5 minutes. Turn both
switches OFF.
Start from 4 PUTTING INTO OPERATION.
In case of recurrence, please consult DecoRad® Systems
E17
Temperature
sensor
Leave the UV lamp to cool down for 5 minutes. Turn both
switches OFF.
Start from 4 PUTTING INTO OPERATION.
In case of recurrence, please consult DecoRad® Systems
U51
(DIST)
Distance
The lamp-unit is turned too far from the object for more
than 30 seconds.
Please position the Handmate between 2 –4 cm distance
from the floor, cure at approx. 3 cm
U94
(TIME)
Time
management
Auto OFF after 5 minutes no use

Handmate UV 1800 Firmware 2.9
16
6. Replacing lamp
Replacing UV lamp:
Caution: never touch a heated UV lamp!!
Step 1: Place the Handmate on a flat surface with the
lamp facing up.
Step 2: Disconnect from the power source.
Step 3: Remove the 13 screws with a socket wrench and
flip the bottom plate carefully to the side. Remove the old
UV lamp by pulling the ceramic parts of the lamp.
Step 4: Place new UV bulb by using a tissue.
Reassemble the 13 screws carefully, do not over tighten.

Handmate UV 1800 Firmware 2.9
17
7. Specifications
Handmate UV 1800
General
Description
DecoRad® Handmate UV 1800
Brand
DecoRad®
Colour
Silver / black
Distance to object
2 –35 cm
Cure path
20 cm
Measurements and weights
Weight hand unit (kg)
Appx. 1,3
Measurements hand unit (cm)
26 x 26,5 x 16 (LxWxH)
Measurements power supply/switch unit/suitcase
(cm)
58 x 39 x 28 (LxWxH)
Weight suitcase (kg)
Appx. 11,5
Total weight (kg)
Appx. 13,45
Power supply
Power UV - ultraviolet (Watt)
1800
Power Voltage
110 - 250 Vac 50/60 HZ
10 –20 Amp circuit
Cable powering (cm)
225
Cable from switch to hand unit (cm)
800
Electronic ballast
1-3,5 kW
Lamps
Type UV-lamp
UV-1800 W
Number of UV-lamp(s)
1
Burning hours UV-lamp(s)
Appx. 500
Start-up time UV-lamp(s)
Appx. 60 seconds
Cool down-time
Appx. 7 minutes
Ozone free or ozone producing
At your choice
Warranty (excluding (IR) & UV lamp(s))
Manufacturer's warranty
1 year
Warranty type
Carry-in
Inspections
CE Approved
✓
Accessories
Standard
Service and repair manual, safety
package, box.
Optional
Extension pole, support wheel.

Handmate UV 1800 Firmware 2.9
18
We, DecoRad® Systems bv
Fokkerstraat 25
3905 KV Veenendaal
The Netherlands
Declares fully under own responsibility that the equipment specified in this
declaration complies with the conditions as defined in:
Machinery Directive : :2006/42/EC
EMC Directive :2004-108/EG
Low Voltage Directive :2006/95/EC
and the standards:
EN 12921-1:2005+A1 (2010) :Machines for surface preparation using liquids or vapors
EN ISO 12100 (2010) :Safety of Machinery
EN 61000-3-2 (2006) :Harmonic Current Emissions
EN 60204-1(2006) :Electrical equipment of machines
EN 61000-3-3 (2008) :Limitation of voltage changes, voltage fluctuations and flicker
EN 61000-6-2 (2005) :Immunity for industrial environments
EN 61000-6-3 (2007) :Emission standard for residential, commercial and light-
industrial environments
EN 61000-6-4 (2007) :Emission Standard for Industrial Environments
Product :DecoRad® Handmate 1800
UV drying/curing device
Veenendaal, Date :06 May 2020
Name :A.J. Maatkamp
Function :General Manager Decorad Systems BV
Table of contents
Popular Industrial Equipment manuals by other brands

probst
probst TSZ-UNI operating instructions

Ferguson Enterprises
Ferguson Enterprises ProFlo ACF3001CRT2 installation instructions

Ingersoll-Rand
Ingersoll-Rand ARO SB20 Series manual

Siemens
Siemens 3VL9000-4WL00 operating instructions

Baldwin Boxall
Baldwin Boxall VIGIL Eclipse5 Installation details

Endress+Hauser
Endress+Hauser Liquiphant M/S FTL5 Series operating instructions