TYPICAL WIRING DIAGRAM
NOTE: To meet UL requirements, fuse the module supply at 167% of supply current.
DEEP SEA ELECTRONICS
DSEE400 Installation Instructions
053-180
ISSUE 5
ACCESSING THE FRONT PANEL EDITOR
•Ensure the engine is at rest and the module is in STOP mode by pressing the
Stop/Reset button.
•Press and hold the Stop/Reset and Auto buttons simultaneously.
•If a module security PIN has been set, the PIN number request is then shown:
•Press the Auto button, the first ‘#’ changes to ‘0’. Press Up or Down buttons to adjust it to the
correct value.
•Press and hold the Up button when the first digit is correctly entered. The digit you have just entered will
now show ‘#’ for security.
•Repeat this process for the other digits of the PIN number. Press and hold the Down button if previous digits
need to be edited. Press the Auto button to finish editing the PIN.
•Press the Auto button to check the PIN for validity. If the number is not correct, the PIN must be re-entered.
•If the PIN has been successfully entered (or the module PIN has not been
enabled), the editor is displayed:
EDITING A PARAMETER
•Enter the editor as described.
•Press and hold the Up or Down buttons to cycle to the section you wish to view/change.
•Press the Up or Down buttons to select the parameter you wish to view/change within the currently
selected section.
•To edit the parameter, press the Auto button to enter edit mode. The parameter begins to flash to indicate
that you are editing the value.
•Press the Up or Down buttons to change the parameter to the required value.
•Press the Auto button to save the value. The parameter ceases flashing to indicate that it has been saved.
•To exit the editor and save the changes, press and hold the Auto button.
•To exit the editor and not save the changes, press and hold the Stop/Reset button.
NOTE: The editor is exited after 5 minutes of inactivity to ensure security.
NOTE: The PIN number is automatically reset when the editor is exited (manually or automatically) to
ensure security.
NOTE: More comprehensive module configuration is possible using the DSE Configuration Suite PC
Software, refer to DSE publication 057-251 DSEE400 Configuraiton Suite PC Software Manual.
Deep Sea Electronics Ltd.
Tel:+44 (0)1723 890099
Email: support@deepseaelectronics.com
Web: www.deepseaelectronics.com
Deep Sea Electronics Inc.
Tel: +1 (815) 316 8706
Email: USASupport@deepseaelectronics.com
Web: www.deepseaelectronics.com
FRONT PANEL EDITOR PARAMETERS
Section
Parameter As Shown On Display
Value
Display
Contrast
66 %
Backlight Level
100 %
Language
English
Current Date and Time
Day:month:year,
hour:minute:seconds
Engine
Oil Pressure Low Shutdown (If Set)
1.03 bar, kPa, psi
Oil Pressure Low Pre Alarm (If Set)
1.24 bar, kPa, psi
Coolant Temperature High Pre Alarm
(If Set)
90 ºC, ºF
Coolant Temp High Controlled
Shutdown (If Set)
92 ºC, ºF
Coolant Temperature High Shutdown
(If Set)
95 ºC, ºF
Pre Heat Temperature (If Set)
50 ºC, ºF
Pre Heat Timer
0 h 0 m 0 s
Post Heat Temperature (If Set)
50 ºC, ºF
Post Heat Timer
0 h 0 m 0 s
Under Speed Shutdown
Active, Inactive
Under Speed Shutdown
1200 rpm
Under Speed Warning
Active, Inactive
Under Speed Warning
1260 rpm
Over Speed Warning
Active, Inactive
Over Speed Warning
1650 rpm
Over Speed Shutdown
1710 rpm
Overspeed Overshoot
0s
Overspeed Overshoot
0%
Battery Under Voltage Warning
Active, Inactive
Battery Under Voltage Warning
10.0v
Battery Under Voltage Warning Delay
0h 1m 0s
Battery Over Voltage Warning
Active, Inactive
Battery Over Voltage Warning
30.0v
Battery Over Volts Warning Delay
0h 1m 0s
Charge Alternator Failure Pre-Alarm
Active, Inactive
Charge Alternator Failure Pre-Alarm
6.0v
Charge Alternator Failure Pre-Alarm
Delay
0h 0m 5s
Charge Alternator Failure Shutdown
Active, Inactive
Charge Alternator Failure Shutdown
4.0v
Charge Alternator Shutdown Delay
0h 0m 5s
Battery Under Voltage Warning
Active, Inactive
Battery Under Voltage Warning
10.0v
Battery Under Voltage Warning Delay
0h 1m 0s
Battery Over Voltage Warning
Active, Inactive
Battery Over Voltage Warning
30.0v
Battery Over Volts Warning Delay
0h 1m 0s
Charge Alternator Failure Pre-Alarm
Active, Inactive
Charge Alternator Failure Pre-Alarm
6.0v
Charge Alternator Failure Pre-Alarm
Delay
0h 0m 5s
Charge Alternator Failure Shutdown
Active, Inactive
Charge Alternator Failure Shutdown
4.0v
Charge Alternator Shutdown Delay
0h 0m 5s
Clutch
Clutch Disengage Low Speed
0 rpm
Control
Clutch Engage Speed
0 rpm
Clutch Disengage High Speed
8000 rpm
Clutch Re-Engage
0 rpm
Clutch Disengage Low Speed
0 rpm
PLC
PLC Watched Item (1-16)
[PLC value] units
Instruments
Section
Parameter As Shown On Display
Value
Speed
Cranking Speed
0 rpm
Settings
Warming Speed
0 rpm
Idle Speed
0 rpm
Priming Speed
0 rpm
DPF Regeneration Speed*
Active, Inactive
DPF Regeneration Speed*
0 rpm
Cooldown Speed
0 rpm
Speed
Min Speed
0 rpm
Control
Default Running Speed
0 rpm
Max Speed
0 rpm
Fixed Running Speed
0 rpm
Selectable Speed 1
0 rpm
Selectable Speed 2
0 rpm
Selectable Speed 3
0 rpm
Selectable Speed 4
0 rpm
Linear Min Sensor Value
[Val] <user/units>
Linear Max Sensor Value
[Val] <user/units>
Linear Speed at Min
0 rpm
Linear Speed at Max
0 rpm
Emptying Speed
0 rpm
Filling Speed
0 rpm
Maintain Empty Running Speed
0 rpm
Maintain Empty Emptying Speed
0 rpm
Maintain Empty Setpoint
[Val] <user/units>
Maintain Empty Deadband
[Val] <user/units>
Maintain Fill Running Speed
0 rpm
Maintain Fill Filling Speed
0 rpm
Maintain Fill Setpoint
[Val] <user/units>
Maintain Fill Deadband
[Val] <user/units>
Engine Start Value
[Val] <user/units>
Engine Stop Value
[Val] <user/units>
Maintenance
Maintenance PIN protect
Active, Inactive
Maintenance Alarm 1
10h
Maintenance Alarm 2
10h
Maintenance Alarm 3
10h
Maintenance Alarm 4
10h
Maintenance Alarm 5
10h
Maintenance Alarm 6
10h
Maintenance Alarm 7
10h
Maintenance Alarm 8
10h
Maintenance Alarm 9
10h
Maintenance Alarm 10
10h
CAN
CAN Terminator Active
Active, Inactive
DPF Auto Regen Inhibit*
Active, Inactive
DPF Manual Regen*
Active, Inactive
DPF Manual Regen Cancel*
Active, Inactive
Flexible
Flexible Sensor (A-G) Low Alarm
Active, Inactive
Sensors
Flexible Sensor (A-G) Low Alarm
[value] <unit>
Flexible Sensor (A-G) Low Pre-Alarm
Active/Inactive
Flexible Sensor (A-G) Low Pre-Alarm
[value] <unit>
Flexible Sensor (A-G) High Pre-Alarm
Active/Inactive
Flexible Sensor (A-G) High Pre-Alarm
[value] <unit>
Flexible Sensor (A-G) High Alarm
Active/Inactive
Flexible Sensor (A-G) High Alarm
[value] <unit>
Timers
LCD Page Timer
0h 5m 0s
LCD Scroll Delay
0h 0m 2s
Start Delay Off load
5s
Start Delay On load
5s
Start Delay Telemetry
5s
Delayed Engine Start
0h 0m 30s
Cranking
0m 10s
Cranking Rest
0m 10s
Section
Parameter As Shown On Display
Value
Timers
Safety On Delay
0m 10s
Cont.…
Smoke Limiting
0h 0s
Smoke Limiting Off
0h 0s
Warming
0h 0m 0s
Return Delay
0h 0m 30s
Cooling
0h 1m 0s
Cooling at Idle
0h 1m 0s
Failed To Stop Delay
0m 30s
Delayed Engine Stop
0h 0m 30s
Engine Speed Transient Delay
0.0s
Priming Delay
0h 0m 30s
Selectable Speed Transfer Delay
0m 0.2s
DPF Ramp*
5s
Scheduler
Schedule
Active, Inactive
Schedule Period
Wkly/Mthly (If Active)
Schedule Time & Date Selection (1-8)
See Editing A
Parameter
1 Schedule
Off Load / On Load /
Auto start inhibit
Week 1 (If Monthly selected)
Wk1, Wk2, Wk3, Wk4
On
00:00
Run Time
00:00
M T W T F S S
Select day
Active
Active Config Select
<Main Config>
Configuration
<Alt Config 1>
<Alt Config 2>
<Alt Config 3>
<Alt Config 4>
*Electronic Engines Only
ACCESSING THE SPEED CONTROL EDITOR
•Ensure the engine is at rest and the module is in STOP mode by
pressing the Stop/Reset button.
•Navigate to the Active Configuration screen in the Engine section of the
module’s display.
•Press and hold the Up and Down buttons simultaneously to
enter the editor, no PIN is required.
•Edit the parameters as described overleaf in the Editing a Parameter
section.
DIMENSIONS AND MOUNTING
For flat surface mounting in a Type 1 enclosure to meet UL requirements
DIMENSIONS
189 mm x 125 mm x 54 mm
(7.5” x 4.9” x 2.1”)
MOUNTING HOLE SPACING
165 mm x 68 mm
(6.5” x 2.7”)
PANEL CUTOUT
148 mm x 112 mm
(5.8” x 4.4”)
MOUNTING HOLE
DIAMETER
Suitable for M4
(5/32” diameter)
CONNECTORS & WIRING HARNESS
Details
DSE Part
Number
Manufacturer’s
Part Number
Manufacturer
Connector A
007-850
DT16-18SA-K004
Deutsch
Connector C
007-851
DT16-18SC-K004
Deutsch
1.2 m Wiring Harness
Complete With
Connector A & C.
007-852
-
DSE

Other DEEP SEA ELECTRONICS Control System manuals

DEEP SEA ELECTRONICS DSE8610 MKII User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSE8610 MKII User manual

DEEP SEA ELECTRONICS DSE860 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSE860 User manual

Popular Control System manuals by other brands

Siemens SINUMERIK 840D sl Commissioning manual

Siemens

Siemens SINUMERIK 840D sl Commissioning manual

CSI COMPACT CIP Installation operation & maintenance

CSI

CSI COMPACT CIP Installation operation & maintenance

Tecnoalarm TP8-64 BUS Installer manual

Tecnoalarm

Tecnoalarm TP8-64 BUS Installer manual

FRC Turbofoam TFC100 user manual

FRC

FRC Turbofoam TFC100 user manual

Axiom Precision AUTO ROUTE PRO V5 manual

Axiom Precision

Axiom Precision AUTO ROUTE PRO V5 manual

Okuma VTM-200 Operation & maintenance manual

Okuma

Okuma VTM-200 Operation & maintenance manual

HBX HydroBloc 0110 installation manual

HBX

HBX HydroBloc 0110 installation manual

GE Mark VIe System guide

GE

GE Mark VIe System guide

ZIEHL-ABEGG ZETADYN 1DV Series System description

ZIEHL-ABEGG

ZIEHL-ABEGG ZETADYN 1DV Series System description

Siemens SIMATIC C7-635 manual

Siemens

Siemens SIMATIC C7-635 manual

FAAC J275 2K HA manual

FAAC

FAAC J275 2K HA manual

ABB IEC 61850 quick start guide

ABB

ABB IEC 61850 quick start guide

Mitsubishi SC-SL4-AE installation manual

Mitsubishi

Mitsubishi SC-SL4-AE installation manual

zipwake S Series installation guide

zipwake

zipwake S Series installation guide

MITECH FOSTER Series Installation and use manual

MITECH

MITECH FOSTER Series Installation and use manual

Elkron ELR600RT/10 manual

Elkron

Elkron ELR600RT/10 manual

Polyaire ZoneMaster ZoneSwitch V2 Operation and installation instructions

Polyaire

Polyaire ZoneMaster ZoneSwitch V2 Operation and installation instructions

Bosch Rexroth IndraControl XM21 operating instructions

Bosch

Bosch Rexroth IndraControl XM21 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.