Recommendation
IMPORTANT
Refer to the maintenance notice (NM-245) when carrying
out any repairs or modifications. Notice available on our
website http://www.definox.com/
AIR QUALITY
Dry air filtered at 10µm
Operating pressure : 5 to 7 bars
ELECTRICAL
Compression gland PG9
Terminal or multi-voltage module version:
Conductor section: 0.5mm² recommended and 0.75mm²
max.
Cable dia. 4 to 8mm.
AS-i version:
Refer to the maintenance notice (NM-245).
Disassembling the base from the top
Unscrew the locking screw [E].
Turn the connector [A] to unlock while holding the base to
release the mounting brackets. Hold the base and pull the
connector.
Assembling the base on the actuator
Screw the detection cam [B] and NO or NC connection
(according to the configuration).
Position the base on the actuator, insert the two screws [F]
and tighten (M8 tightening torque: 1N.m or 10Kgf.cm).
Assembling connector onto the base
Position the control top on the base inserting the 3 mounting
brackets and respecting the action way of arrow [C] first, and
then arrow [D]. Tighten the screw [E] on the base.
Locking and unlocking the housing
Locked housing Unlocked housing
When the housing is unlocked ; put it away.