Delixi JLXK1 Series User manual

JLXK1 Series Travel Switch
User Manual
□ Please carefully read this User Manual before
installing and operating the product, and keep this
manual properly for future reference

JLXK1 Series Travel Switch
User Manual
Safety Notice
Please carefully read this instruction before the installation, operation, run, maintenance, and inspection,
and follow the contents of the instruction to properly install and operate this product.
Danger:
⚫Do not operate the travel switch with wet hands;
⚫It is forbiddent to touch the live parts during operation;
⚫Mark sure that the product is deenergized during the maintenance and service;
Caution:
⚫The installation, maintenance and service shall be performed by the qualified professional;
⚫Various characteristics of product have been set in factory and cannot be disassembled or adjusted
without permission during operation;
⚫Please confirm that the rated voltage, rated current, frequency and characteristics of the product meet
the operating requirements before use;
⚫If found damage or abnormal sound when unpacking, please stop the machine immediately and
contact the supplier;
⚫When scrapping the product, please dispose the product waste properly. Thanks for your cooperation.

About JLXK1 Series Travel Switch
●Panel introduction
Legends:
1. Hit head structure form
2. Company logo
3. Product model
4. Standard: GB/T 14048.5
5. Resistive current in free air Ith=5A
6. Certification mark
7. Protection grade: IP62 (after installation)
8. Technical parameters
AC –15 Ue: 380V Ie:0.3A
DC –13 Ue:220V Ie:0.12A
Table 1: Hit head structure type and basic data
Model
Hit head
structure form
Number of contact
pairs
Action
stroke or
angle
Overstroke
or angle
Contact
conversion
time s
Action
force
N
Normally
open
Normally
closed
JLXK1-111
Single-wheel
type, auto
reset
1
1
15°-20°
≥30°
≤0.04
≤10
JLXK1-211
Dual-wheel
type, non-auto
reset
1
1
≤45°
≥30°
≤0.04
≤15
JLXK1-311
Push rod type,
auto reset
1
1
1-3mm
≥2mm
≤0.04
≤20
JLXK1-411
Roller push
rod type, auto
reset
1
1
1-3mm
≥2mm
≤0.04
≤20
JLXK1-511
Universal,
auto reset
1
1
20±5mm
-
≤0.04
≤15

Normal Operation, Installation and Transport Conditions
●Normal operation and installation conditions
(1) The ambient air temperature is not higher than +40℃, and is not below -5℃; the average value within 24
hours does not exceed +35℃;
(2) The altitude of the installation site does not exceed 2000m;
(3) The relative humidity of the atmosphere does not exceed 50% at the maximum ambient temperature of +40℃,
and a higher relative humidity is allowed at lower temperatures, such as 90% at 20℃. Special measures shall be
taken for condensation occasionally generated due to temperature changes.
(4) The product can be installed in any installation angle;
(5) Installed in a place where there is shock vibration for obvious shaking without rain or snow erosion;
(6) Pollution level: Level 3;
(7) Installation category: Class II;
(8) Rated impulse withstand voltage: 6kV;
(9) Protection grade: IP62 after installation.
●Normal Storage and Transport Conditions
(1) Temperature: -25℃~+55℃;
(2) Relative humidity: ≤90%;
(3) During transport, please gently handle the product, do not upside the product down, and prevent harsh
collision;
Install product
●The outline dimensions and installation dimensions are shown below:

Signage

Stroke Stroke
●Debugging and operation
(1) Check whether the technical parameters on the product nameplate meet the working requirements.
(2) Fix and tighten the product with screws. (It is recommended that spring washers and flat gaskets are used).
(3) After installation, please carefully check the Hit headfor blockage when being pushed and whether the switch
core works within the specified range; if found any fault, check and re-install it, and then connect the lead wire.

(4) Wire selection. 1~2 copper wires with a cross-sectional area of 0.5mm²~1mm²are used.
(5) When connecting the lead wire, refer to the wiring diagram above the core. The NC means normally closed
contact, and NO means the normally open contact. The diagram is shown in figure. Please carefully distinguish
the normally open and normally closed contact terminal sets at the core wiring terminal of the switch to prevent
reverse or wrong connection.
Fig. Wiring diagram
Maintenance and Service
⚫The installation, maintenance and service shall be performed by the qualified professional;
⚫The product shall be de-energized during the maintenance and servcie;
⚫The mainteance and service is conducted once a year under normal operating conditions, and the mainteance
contents are listed in table below. Table Maintenanc and Service
Item
Contents
Appearance
No dust, no condensation, clean if necessary
No damage
No color changes on the shell and connecting terminal
Wiring terminal connection
Tighten it according to the tightening torque 0.8N
without any looseness.
Switch making and breaking reliabilty
Check whether the swtich is connected or disconnected
before and after action.
Company Commitment
Under the condition that users follow the use and storage conditions and the product are well sealed, within 36
months from the production date, our company will provide repair and replacement service free of charge for any
damage or abnormal operation due to poor manufacture quality. A paid repair will be provided if the warranty
period expires. For any damage due to one of the following situations, a paid repair will be given even if within
the warranty period:

(1) Improper operation, maintenance, or storage;
(2) Modified without permission or improper repair;
(3) Damage due to falling off or caused during installation after purchase;
(4) Force majeure such as earthquakes, fires, lightning strikes, abnormal voltages, and secondary disasters;
If you have any question, please contact the dealer or our company’s customer service department.
Customer service hotline:400-826-8008
Certificate
DELIXI ELECTRIC LTD
Name: Travel Switch
Model: JLXK1 Series
This product passes the inspection and is allowed to be
shipped
Standard: GB/T 14048.5
Inspector: Check 05
Production date: See label on inner box
Manufacturer: Zhejiang Delixi Electrical Co., Ltd.
Address: Delixi High-Tech Industrial Park, Liushi Town, Yueqing City, Zhejiang P/C: 325604
Tel: (86-577) 61778888
Fax: (86-577) 61778000
Customer Service Hotline: 400-826-8008
www.delixi-electric.com
The first edition of this User Manual was issued in April 2020.