PowerConnect 8024/8024F Release Notes
Page 10 System Firmware Version 3.1.4.16
Description User Impact Resolution
Read-write user gets Read-only
access for telnet and SSH session,
when authentication method is
RADIUS.
Read-write user gets Read-only
access for telnet and SSH session,
when authentication method is
RADIUS.
Use access level assigned by the
radius server instead of getting from
the local user database.
Traffic matching with COS 7 is getting
dropped, when inbound MAC ACL is
configured on the interface with vlan
priority as 7.
Traffic matching with COS 7 is getting
dropped, when inbound MAC ACL is
configured on the interface with vlan
priority as 7.
Corrected logic that configures vlan
priority as 6, when user is trying to
configure priority 7.
Switch crashes when File System
page is accessed after configuring file
descriptor through CLI with more than
128 characters length.
The switch reboots. Increased buffer size to be 256.
Configured non-existing host cannot
be deleted for logging syslog Only valid servers could be deleted by
the user. Updated logic to remove non-
existing hosts also in CLI command
handler.
Able to successfully configure Banner
MOTD from WEB, but unable to
disable successfully.
Able to successfully configure Banner
MOTD from WEB, but unable to
disable successfully.
Added a checkbox in the web page
that to enable/disable MOTD
message.
Local user database does not accept
a user without a password from web,
although password minimum length is
disabled.
The Web would not accept the
username without a password which
was inconsistent with the CLI.
Changed the text box property to
allow empty password also.
UDP data is not received by the
mrouter interface at egress vlan even
though L2 MFDB table showing both
join registered interface and mrouter
interface
Querier attached interfaces will not
receive mcast data traffic Add support for interfaces on which
queries are recevied.
Observed Internal BRCM_escape_lt;
brBRCM_escape_gt; words are
displayed on clicking Route
Redistribution Summary web page
Irrelevant text displayed on the web
page. Modified object handler code to
interpret html tags correctly.
Out Of Band Port status is shown as
UP, even though it's shutdown. Incorrect status communicated to the
user. Update the status in PHY, when
service port is shutdown
Huge running-config display hogs up
screen space with downloaded image
for captive poral
It's an inconvienence to the CLI user
for the need to scroll past unreadable
data.
Remove all encoded binary and
Unicode from "show running-config".
Show encoded binary and Unicode
for show scripts (and show all)
commands.
Precede encoded binary and
Unicode with user notification
indiciating unreadable data.
Most encoded binary and Unicode
to the END of the show scripts (and
show all) command output.